Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108048035791 (International callers) or 08048035791 (Indian callers).
Model: PI – 542A
Display: 4 Digit, 0.5” 7 segment RED LED
Analog inputs: 0 - 20 mA, 0 to 70 mV, 0 - 10 V DC, 0.0 – 400.0 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Display Range: -1999 to 9999 counts (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 800.0°C )
TC - J (- 200 to 200°C )
TC - K (- 200 to 1372°C )
TC - R ( 0 to 1765°C )
TC - S ( 0 to 1762°C )
TC - T (- 199.9 to 400.0°C )
TC - B ( 600 to 1800°C )
TC - N (-200 to 1300°C )
TC - E ( -199.9 to 916.0°C )
Accuracy:
0.05% FS ±1 counts (Except Thermocouple)
0.05% FS ±2 counts (only for Thermocouple)
Unit selection: °C / °F (for RTD & TC inputs)
Analog input resolution mV, mA & V: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.01 (For RTD - PT 100 input (°C) only) /0.1 / 1 °C / °F
Filter constant: 1 – 100% (adjustable)
Relay Output* (optional): 2 Relay (5A rated) with 4 Relay Status Selection, Adjustable Hysteresis, Cyclic Delay
Re Transmission* (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication* (optional): RS 485 (2 wire) MODBUS RTU protocol
PC Software* (optional): Monitoring, Data logging, Report & graph
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Operating environment: 0 to 50°C / 5 to 95% RH non condensing
Power supply: 90 to 270 V AC / DC / 50/60 Hz
Overall Dimensions: 48(H) X 96(W) X 110(D) mm
Cut out Dimension: 44(H) x 90(W) mm
Housing: Panel mountable ABS plastic
Weight: 300 grams (Approx.)
Descriptions:
Measurement of relevant climatic data is becoming more and more important. This Humidity & Temperature Indicator offer very accurate measurement of Relative Humidity and Temperature by Excellent readability of the very high intensity seven segment LED display.
The Humidity & Temperature Indicator housed with roughest case allow the use in tough industrial environments, Latest technology and well proven sensor guaranteed highest accuracy and long term stable measurement.
Model : HT 191J
Display : 4+4 Digit 2' or 4' or 8' Seven Segment LED Display
Range : 0-60°C 0-100%RH (Depends on Sensor)
Resolution : 0.1 or 0.01 C / 0.1% RH
Accuracy : Depends on Sensor
Mounting : Wall Mountable
Operating Temp.& Humd : 0-50°C/20 to 95% RH Non Condensing
Power Supply : 230V AC 50Hz
Weight : 5kg (Approx..)
Model: PIJ – 542 A1
Display: 2” or 4” or 8” 4 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -1999 to 9999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F)
TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999.9°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Temperature drift: ≤ 0.1% FS/°C (typical 50 ppm)
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Optional
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 428 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 4.5 kg
Model: PIJ – 542 C1
Display: 2” or 4” or 8” 4 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -1999 to 9999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F)
TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999.9°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Optional
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 760 x 320 x 85 (or) 1125 x 320 x 85 (L x H x D) in mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 7.5 (or) 8.5 kg
16 Characters LCD Display
mV / mA / Volt Analog Inputs
Wide Input Ranges ± 75mV / ± 10V
Wide Display Ranges - 199999 to +199999
Parameter & Unit Display User Front Configurable
2 Relay Outputs with Configurable H / L Setting(Optional)
Re Transmission Output (Optional)
24 V DC Sensor Supply
Universal Supply Voltage 90 to 270V AC / DC
Model: PI – 541A
Display: 6 Digit 7 segment RED LED
Inputs: 0 - 20 mA, 0 to 75 mV, -10 to 10 V DC, 0 – 4000 Ω (H & L Limit Programmable)
RTD - PT 100, PT-1000, Thermocouple - J, K, R, S, T, B, N, E
Cold junction Accuracy: ± 0.3°C
Resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1°C Selectable for Analog
0.01°C for RTD and 0.1°C for TC
Unit selection: °C / °F (for RTD & TC inputs)
Linearization: Programmable custom Linearization provided (1 - 21 points)
Input signal filter: 1 – 100% user configurable
Cold junction compensation: Automatic inbuilt ‘CJC’ is provided
Relay Output* (optional): 2 Relay (5A rated) with 4 Relay Status Selection, Hysteresis, Cyclic Delay
Alarm settings: Front key settable
Alarm indication : Two LED on front panel
Re Transmission* (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC for process variable
PC communication* (optional): RS 485 (2 wire) MODBUS protocol
PC Software* (optional): Monitoring, Data logging, Report & graph
Sensor excitation Supply: 24 V DC ±10% @ 100 mA
Power supply: 90 to 270 V AC / DC / 50/60 Hz
Front panel : IP 65 protection
Operating environment: 0 to 50°C / 5 to 95% RH non condensing
Overall Dimensions: 48(H) X 96(W) X 110(D) mm
Cut out Dimension: 44(H) x 90(W) mm
Enclosure: ABS plastic
Weight: 350 grams (Approx.)
Model : HTP 196
Display : 3 line 4digit ,0.5” 7 segment LED
Range : 0 to 60°C / 0to100%RH/ 0 to 2000mbarA
Resolution : 0.01 or 0.1°C / 0.1% RH / 1 mbar
Accuracy : ± 0.5 °C / ± 3%RH / ± 0.5 % FS
Mounting : Wall mountable
Power supply : 90 to 270V AC
Dimension : 100 mm W x 250 mm H x60 mm D
Weight : 640gms
Sensor : P T-100, Humidity & Pressure sensor with 2 meter cable