Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108048035791 (International callers) or 08048035791 (Indian callers).
Descriptions:
Measurement of relevant climatic data is becoming more and more important. This Humidity & Temperature Indicator offer very accurate measurement of Relative Humidity and Temperature by Excellent readability of the very high intensity seven segment LED display.
The Humidity & Temperature Indicator housed with roughest case allow the use in tough industrial environments, Latest technology and well proven sensor guaranteed highest accuracy and long term stable measurement.
Model : HT 191J
Display : 4+4 Digit 2' or 4' or 8' Seven Segment LED Display
Range : 0-60°C 0-100%RH (Depends on Sensor)
Resolution : 0.1 or 0.01 C / 0.1% RH
Accuracy : Depends on Sensor
Mounting : Wall Mountable
Operating Temp.& Humd : 0-50°C/20 to 95% RH Non Condensing
Power Supply : 230V AC 50Hz
Weight : 5kg (Approx..)
Model: PIJ – 542 A1
Display: 2” or 4” or 8” 4 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -1999 to 9999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F)
TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999.9°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Temperature drift: ≤ 0.1% FS/°C (typical 50 ppm)
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Optional
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 428 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 4.5 kg
Model: PIJ – 542 C1
Display: 2” or 4” or 8” 4 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -1999 to 9999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F)
TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999.9°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Optional
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 760 x 320 x 85 (or) 1125 x 320 x 85 (L x H x D) in mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 7.5 (or) 8.5 kg
16 Characters LCD Display
mV / mA / Volt Analog Inputs
Wide Input Ranges ± 75mV / ± 10V
Wide Display Ranges - 199999 to +199999
Parameter & Unit Display User Front Configurable
2 Relay Outputs with Configurable H / L Setting(Optional)
Re Transmission Output (Optional)
24 V DC Sensor Supply
Universal Supply Voltage 90 to 270V AC / DC
Model : pH 641
Display : 0.5” 3 ½ Digit 7 segment Red LED
Range : 0 to 14 pH / -1999 to 1999 ORP
Input Impedance : > 10¹² Ohms
Accuracy : ± 0.01 pH ± 1 digit / ± 1 ORP ± 1 digit
Resolution :0.01 pH
Electrode: Combined Electrode with BNC attachment
Input connection : BNC socket
Operating Environment : 0 to 50 °C / 20 to 95 % RH non condensing
Power supply : 230V AC / 50 Hz ± 10%
Overall Dimension in mm : 48 x 96 x 65 (H x B x L)
Cut out Dimension in mm : 44 x 92 (H x B)
Instrument Weight : 170 g
Model : CC 100
Display : 0.5” 4 Digit 7 segment Red LED
Range :0 to 9999 counts
Input : Count Pulse for Electronic Marker Pen
Resolution : 1 count
Disk Diameter : 110 mm
Magnification : x1.7 Surface
Count Reset : Push Button Provided on front panel
Input connection : 2 Pin Female Socket
Operating Environment : 0 to 50 °C / 20 to 95 % RH non condensing
Power supply : 230V AC / 50 Hz ± 10%
Overall Dimension in mm : 220 x 200 x 105 (L x B x H)
Instrument Weight : 2.5 kg (Approx.)
Model :DN 1000
Display : 0.5” 3 ½ Digit 7 segment Red LED
Range : 0 to 19.9 & 199.9 NTU
Resolution : 0.1 NTU
Detector : Photo Diode
Test Tube : 30mm Dia Clear Glass Test tube x 4 nos
Light Source : High Intensity 5mm White LED
Operating Environment : 0 to 50 °C / 20 to 95 % RH non condensing
Power supply : 230V AC / 50 Hz ± 10%
Overall Dimension in mm : 220 x 200 x 110 (L x B x H)
Instrument Weight : 1.7 kg (Approx.)
Model: Pcal 1300 / 700 bar
Range (bar): 0 to 700 bar
Pressure media: Oil & Water
Pressure pump: CT – 02
Display: 128 × 64 COG Graphic LCD with White LED Backlight
Resolution (bar): 6 digit user selectable
Instrument Port: ½” BSP Male x 10 mm long
Instrument dimension: 100 × 100 × 55 (W × H × D) mm
Instrument Weight: 400 gms (Approx.)
Stability time: 1 to 2 mins
Accuracy: ± 0.05% FS
Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero: One touch zero provided on front key
Pressure Peak: Maximum & minimum with user reset option
Pressure overflow: FS X 2 (Max.)
Pressure burst: FS X 3 (Max.)
Temp.Measure: RTD - PT 100 (2,3,4, wire selectable)
Temp. Range: -199.999 to 850.000
mA Measure: 0-24 mA (scalable)
Display scale: -99999 to 99999 counts (for mA measure input)
Switch test: Provided
Display Hold: One touch hold provided on front key
Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
Pump Weight (Approx.): 14 kg
PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
PC Software (optional): Windows-based semi-automatic calibration software (Optional)
Model: DCM 200
Display: 0.5” 3 ½ Digit 7 segment Red LED
Range: 0 – 20 μS/ 200 μS/ 2000 μS/ 20 mS / 200 mS ( 5 range selection using front rotary switch )
Resolution: 0.01 / 0.1 / 1 for μS range & 0.01 / 0.1 for mS range
Accuracy: ± 1 % of Range ± 1 digit
Temperature Compensation: 0 to 50°C (Manual) continuously adjustable
Cell Constant: Adjustable with indication on display
Sensor: Platinum Conductivity cell (1.0 cell constant) with Banana male connector
Input Connection: Banana socket
Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing
Power supply: 230V AC / 50 Hz ± 10%
Overall Dimensions in mm: 185 x 235 x 65 ( L x B x H )
Instrument weight: 1.6 kg (Approx.)
Model : TCAL 1503 / -100
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -100°C to 40°C @20°C to 30°C Ambient
Resolution : 0.01 °C
Block Stability (30 mins) : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.05 °C at full range
Temperature Read out : °C / °F (selectable)
Heating time :
25°C to 40°C : 30 min
-100 to 25°C : 80 min
Cooling Time: 25°C to -100°C : 85 min
40 to 25°C : 12 min
Stabilization time : 15 minutes
Insert Dia. x Height: 30 x 120 mm
Test sensor immersion depth: 115 mm
Standard well holes in mm : Insert No. 1 : 5.1, 6.2, 6.2 & 8.1
Insert No. 2 : 6.2, 6.2 & 10.2
Measure inputs: RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, V, mV, Ohms
Cold junction Accuracy: ± 0.3°C
Communication: RS 485 MODBUS
Switch Test: Provided
Sensor supply output: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption : 500 VA
Overall Dimension in mm : 356 x 210 x 534 (L x B x H)(Approx.)
Instrument Weight :15.9 kg(with well insert)(Approx.)
Model: HTD 200
Display: 2.8” True colour TFT display with touch screen
Range:
Temperature: -40 to 85 °C (T), Humidity: 0 to 100% RH (RH)
Resolution: 0.01 °C / 0.01 % RH
Accuracy at 23 °C± 5 °C : ± 0.2 °C / ±0.8 % RH
Psychometric calculated indication: Dew / Frost point ( Dp / Fp )
Wet Bulb Temperature ( Tw )
Vapour partial pressure ( E )
Vapour Saturation pressure ( Ew )
Mixing ratio by weight (dry) ( g / kg )
Enthalpy ( H ) ( KJ / kg )
Specific Humidity (moisture) ( g / kg )
Absolute Humidity (moisture) ( g / m³ )
Volume mixing ratio (dry) ( ppm )
Calculation method: WMO method
Display refresh rate: 1 s (typical)
Calibration : 5 point lookup table for both Temperature & Humidity
Alarm: Audible & Visible user settable individual High & Low alarm set with alarm mode selection for all the 3 parameters
Touch sound: On / Off option available
Logging interval: 1 sec to 24 Hrs programmable
Memory capacity: 4 to 32 GB Internal storage
Data download: Via USB
Battery charging port: USB C type
Integrated battery: 3.7V / 10,000 mAh Inbuilt rechargeable polymer Li-ion battery
Backlight time interval: 0(OFF) to 59 mins : 59 secs (user adjustable)
Brightness adjustment: 10 to 100% (user adjustable)
Application environment range: -10 to 60 °C / 0 to 100% RH (non condensed)
Storage environment range: -10 to 45 °C / 10 to 90% RH
Housing material: ABS with anti-slip grip silicon cover
Protection class: IP40
Overall Dimension in mm: 35 x 80 x 165 mm ( L x B x H)
Instrument Weight: 560 g (Approx.)
Model : TCAL 1503 / -40
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -40 to 120°C @23°C Ambient
Resolution : 0.01 °C
Block Stability : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.02°C at full range
Block Axial Uniformity (upto 40mm) : ± 0.18°C at -45°C
± 0.1°C at 0°C
± 0.05°C at 50°C
± 0.11°C at 100°C
± 0.17°C at 120°C
Temperature Read out : °C / °F (selectable)
Loading effect: Better than ± 0.08°C
hysteresis: Better than ± 0.03°C
Cooling time :
30 mins (25 to -45 °C)
15 mins (25 to -30 °C)
65 mins (120 to 25 °C)
Heating time : 25 mins (25 to 120 °C)
75 mins (-45 to 120 °C)
52 mins (-45 to 25 °C)
Stabilization time: 10 minutes
Insert (Dia. x Height): 30 x 160 mm
Test sensor immersion depth: 130 mm
Standard well holes in mm: Insert No. 1 → 5.1, 6.2, 6.2 & 8.1, Insert No. 2 → 6.2, 6.2 & 10.2
Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms
Cold junction Accuracy: ± 0.3°C
UUC Sensor supply input: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (optional 110V AC)
Power Consumption: 500 VA
Switch Test : Provided
Overall Dimension in mm: 390 x 185 x 356 (L x B x H) (Approx.)
Weight: 17.3 kg (with well insert) (Approx.)