Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108048035791 (International callers) or 08048035791 (Indian callers).
Model: MTC-01
Type: R, S
Temperature Range:
(a) 200 to 1500°C
(b) 100 to 1200°C
Accuracy: Class 1 (0.6°C or 0.1% of Temperature which ever is greater)
Temperature Scale: ITS-90
Sheath Material: K-99 grade ceramic
Thermocouple wire dia: 0.5mm
Probe dia & Length: 6mm OD & 450mm Length
Cable Length: 1.5 meter long with male female, Miniature Omega connector
Handle Dimension: 20mm OD & 100mm Length
Calibration Certified: ISO/IEC 17025 Accredited 5 point
“SANSEL” Series BCAL 1502 is a Micro controller Based Precision Temperature Calibrators Generates True Reference Temperature. The Temperature Controller of the Calibrators Uses a Auto Tune PID Control Algorithm. Infra red thermometer & online pyrometer calibration is performed by comparison of the temperature measured by UUC and target temperature indicated by the calibrator or using standard pyrometer. Focus the Unit Under Calibration (UUC) to be Calibrate to the target point given in BCAL 1502. Set the Temperature from the Touch screen display. Both True and set Temperature can be read. When Stabilization Occurs, Simply Read the Temperature and re-Calibrate the UUC.
Model: BCAL 1502
Display: 4.3 inch True TFT LCD Display with Touch screen
Temperature Range: 500 to 1500 °C
Resolution: 0.1°C
Stability: ± 1°C
Radial Uniformity: ± 1% of reading
Bath Temperature Control: Digital Temperature Controller with Auto Tune PID Algorithm
Temperature readout: °C
Aperture area: 30mm
Emissivity: 0.950
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption: 4 KVA
Dimension (W*D*H) (Approx.): 580mm W x 450mm D x 390mm H
Instrument Weight (Approx): 45 kg
Model: TCAL 1501 / 300
Display: 4.3 inch True TFT LCD Display with Touch screen
Temperature Range : Amb. to 300°C
Resolution: 0.01°C
Stability: ± 0.03°C
Radial uniformity: Better than ± 0.2°C
Measure inputs: RTD-PT 50, 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms
Temperature Readout: C
Stabilization Time: 15 minutes
Heating time: 30 mins (25 to 600°C)
Cooling time: 50 mins (600 to 100°C )
Well Dimension: 30 x 150 mm (dia x height)
Test sensor immersion depth: 140 mm
Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1
PC Interface (optional): RS 232 with automatic calibration software
UUC Sensor supply output: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (optional 110V AC)
Power Consumption: 1200 VA
Switch test: Provided
Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.)
Weight: 8.5 kg (without well insert) (Approx.)
Model: Tcal 1501 / -80
Display: 4.3 inch true TFT display with touch screen
Working Range: -80 to -40 °C
Resolution: 0.01 °C
Stability: ± 0.03 °C
Uniformity: ± 0.2 °C
Bath Temperature Control: Digital Temperature Controller with FUZZY PID
Multi Hole Well: Provided for Different type of Sensors, Sensor with Indicator & Thermometer Calibration
Cooling medium: IPA
Liquid Capacity: 5 Liters
Testing Area: 100mm W x 100mm H x 190mm D
Over all Dimension: 705mm L x 505mm W x 825mm H
Power Supply: 230V AC ± 10% / 50Hz (Optional 110V44 AC)
Weight: 80 kg (approx.)
SANSEL Model BCAL 40, Black body Calibrator is used to measure the accuracy and performance of
non-contact fever detection systems, like medical thermometer & image scanner. Now it is being used in relation to COVID-19 (corona virus). This Blackbody Source meets the demand for a simple cost effective solution but high accurate device for the calibration of thermal imager and IR thermometers that are used at temperature around that of the human body.
Unlike Heat only devices, This model uses a solid state Heat & cool Technology, so that this can be generate both Heat and Cool. This having benefits to maintain the block temperature in different ambient temperature.
BCAL 40 using True colour 3.5” Touch screen display, easy to read multi parameter at the same time like Block temperature, Set temperature, Control status, Output % level, range of the equipment, displays both °C & °F and two Touch screen soft keys are used for settings and one more advantage of help menu to guide the operating Instruction of the equipment. Hence no need of hard copy of Instruction manual.
Model: BCAL 40
Display: 3.5 inch True TFT LCD Display with Touch screen
Temperature Range:
Body mode: 20 to 50°C / 68 to 122°F,
Surface mode: 0 to 100°C / 32 to 212°F
Resolution : 0.01°C
Stability: ± 0.03°C
Uniformity: ± 0.3°C
Stabilization Time: 10 minutes
Temperature readout: °C & °F at a time
Heating time: 10 mins (Amb. To 50°C )
Power supply: 90 to 260V AC/DC / 50/60Hz
Power Consumption: Less than 100 VA
Aperture area: 25mm
Emissivity: 0.950
Overall Dimension: 210 x 210 x 140 (L x B x H)(Approx.)
Instrument Weight: 3.7 kg
Model: TCAL 1501 / 1200
Display: 4.3” True TFT LCD Display with Touch screen
Temperature Range: 300 to 1200°C
Resolution: 0.1°C
Stability: Better than ± 0.5°C
Radial uniformity: Better than ± 2°C
Stabilization Time: 30 minutes
Temperature readout: °C
Heating time: 50 mins (Amb. to 1200°C)
Cooling time: 120 mins (1200 to 100°C )
Well Dimension: 39 x 180 x 140 mm (dia x height x depth)
Standard well holes in mm: 5.2, 6.2, 6.2, 10.1 & 12.1
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption: 1900 VA
Overall Dimension in mm: 340 x 175 x 425 (L x B x H) (Approx.)
Weight: 18 kg (without well insert) (Approx.)
MODEL : Pcal 1300/30 bar
Range (bar) :- 0.9 to 30 bar
Pressure media : Air
Pressure pump : HP-03
Display : 128 x 64 COG Graphic LCD with White LED Back light
Pressure Port : 2 x ¼” BSP Female
Pump dimension in mm (Approx.): 230 x 65 x 130 (L x H x W)
Resolution (bar) : 6 digit user selectable
Instrument Port : 1/4 BSP Male x 10 mm long
Instrument dimension : 100 x 100 x 55 (W x H x D) mm
Instrument Weight : 400gms (Approx.)
Stability time : 1 to 2 mins
Accuracy : ±0.05%FS
Pressure units* (selectable) : bar, mbar, Mpa, kpa, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero : One touch zero provided on front key
Pressure Peak : Maximum & minimum with user reset option
Pressure overflow : FS X 2 (Max.)
Pressure burst : FS X 3 (Max.)
Temp.Measure : RTD-PT 100 (2,3,4, wire selectable)
Temp. Range : -199.999 to 850.000
Switch test : Provided
mA Measure : 0-24 mA (scalable)
Display scale : -99999 to 99999 counts (for mA measure input)
Switch test: Provided
Display Hold : One touch hold provided on front key
Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours
with out back light (or) 9V DC adapter / 230V AC supply operated
Pump Weight (Approx.) : 1250 grams
Pc Interface : RS 485
Pc Software : Windows based semi automatic calibration software (optional)
MODEL : Pcal 1300/350 bar
Range (bar) : 0 to 350 bar
Pressure media : Oil & Water
Pressure pump : HP-02A
Display : 128 x 64 COG Graphic LCD with White LED Back light
Pressure Port : 2x 1/2' BSP Female
Pump dimension in mm (Appox.) : 310 x 80 x 165 (LxHxw)
Resolution (bar) : 6 digit user selectable
Instrument Port : 1/4 BSP Male x 10 mm long
Instrument dimension : 100 x 100 55 (W x H x D) mm
Instrument Weight : 400gms (Appox.)
Stability time : 1 to 2 mins
Accuracy : ±0.05%FS
Pressure units (selectable) : bar, mbar, Mpa, kpa, kg/cm2,inHg,cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o
Pressure Zero : One touch zero provided on front key
Pressure Peak : Maximum &minimum with user reset option
Pressure overflow : FS X 2 (Max.)
Pressure burst : FS X 3 (Max.)
Temp.Measure : RTD-PT 100 (2,3,4, wire selectable)
Pressure overflow : FS X 2 (Max.)
Pressure burst : FS X3 (Max.)
Temp.Measure : RTD-PT 100 (2,3,4, wire selectable)
Temp. Range : -199.999 to 850.000
Switch test : Provided
mA Measure : 0-24 mA (scalable)
Display scale : -99999 to 99999 counts (for mA measure input)
Display Hold : One touch hold provided on front key
Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours
with out back light(or) 9V DC adapter /230V AC supply operated
Pump Weight (gms)(Approx.) : 700
Pc Interface : RS 485
Pc Software : Windows based semi automatic calibration software (optional)
MODEL : Pcal 1300/1000 bar
Range (bar) : 0- 1000 bar
Pressure media : oil & Water
Pressure pump : HP-01
Display : 128 x 64 COG Graphic LCD with White LED Back light
Pressure Port : 2 x 1/2' BSP Female
Pump dimension in mm (Approx.) : 340 x240 x320(L xH xW)
Resolution (bar) : 6 digit user selectable
Instrument Port : 1/4 BSP Male x 10 mm long
Instrument dimension : 100 x 100 x 55 (W x H x D) mm
Instrument Weight : 400gms (Approx.)
Stability time : 1 to 2 mins
Accuracy : ±0.05%FS
Temp. Range : -199.999 to 850.000
Switch test : Provided
mA Measure : 0-24 mA (scalable)
Display scale : -99999 to 99999 counts (for mA measure input)
Display Hold : One touch hold provided on front key
Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light (or) 9V DC adapter /230V AC supply operated
Pump Weight (Approx.) : 7500 grams
Pc Interface : RS 485
Pc Software : Windows based semi automatic calibration software (optional)
MODEL : Pcal 1300/2 bar
Range (bar) : -0.9 to 2 bar
Pressure media : Air
Pressure pump : HP-04 ,HP-03
Display : 128 x 64 COG Graphic LCD with White LED Back light
Pressure Port : 2 x1/4 ' BSP Female
Pump dimension in mm (Appox.) : 170 x 45 (Height x Dia)
Resolution (bar) : 6 digit user selectable
Instrument Port : 1/4 BSP Male x 10 mm long
Instrument dimension : 100 x 100 x 55 (W x H x D) mm
Instrument Weight : 400gms (Appox.)
Stability time : 1 to 2 mins
Accuracy : ±0.05%FS
Pressure units (selectable) : bar, mbar, Mpa, kpa, kg/cm2, inHg, cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o
Pressure Zero : One touch zero provided on front key
Pressure Peak : Maximum &minimum with user reset option
Pressure overflow : FS X 2 (Max.)
Pressure burst : FS X 3 (Max.)
Temp.Measure : RTD-PT 100 (2,3,4, wire selectable)
Temp. Range : -199.999 to 850.000
Switch test : Provided
mA Measure : 0-24 mA (scalable)
Display scale : -99999 to 99999 counts (for mA measure input)
Display Hold : One touch hold provided on front key
Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours
with out back light(or) 9V DC adapter /230V AC supply operated
Pump Weight (gms)(Approx.) : 700
Pc Interface : RS 485
Pc Software : Windows based semi automatic calibration software (optional)
MODEL : PCAL 1300/1 bar
Range (bar) : -0.9 to 1 bar
Pressure media : Air
Pressure pump : HP-04
Display : 128 x 64 COG Graphic LCD with White LED Back light
Pressure Port : 2 x1/4 ' BSP Female
Pump dimension in mm (Approx.) : 170 x 45 (Height x Dia)
Resolution (bar) : 6 digit user selectable
Instrument Port : 1/4 BSP Male x 10 mm long
Instrument dimension : 100 x 100 x 55 (W x H x D) mm
Instrument Weight : 400gms (Approx.)
Stability time : 1 to 2 mins
Accuracy : ±0.05%FS
Pressure units (selectable) : bar, mbar, Mpa, kpa, kg/cm2, inHg, cmHg, mmHg, mH₂o, ftH₂o, inH₂o, cmH₂o, mmH₂o
Pressure Zero : One touch zero provided on front key
Pressure Peak : Maximum &minimum with user reset option
Pressure overflow : FS X 2 (Max.)
Pressure burst : FS X 3 (Max.)
Temp.Measure : RTD-PT 100 (2,3,4, wire selectable)
Temp. Range : -199.999 to 850.000
Switch test : Provided
mA Measure : 0-24 mA (scalable)
Display scale : -99999 to 99999 counts (for mA measure input)
Display Hold : One touch hold provided on front key
Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours
without back light(or) 9V DC adapter /230V AC supply operated
Pump Weight (gms)(Approx.) : 700
Pc Interface : RS 485
Pc Software : Windows based semi automatic calibration software (optional)