Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +918048035791 (International callers) or +918048035791 (Indian callers).
Model : HTP 196
Display : 3 line 4digit ,0.5” 7 segment LED
Range : 0 to 60°C / 0to100%RH/ 0 to 2000mbarA
Resolution : 0.01 or 0.1°C / 0.1% RH / 1 mbar
Accuracy : ± 0.5 °C / ± 3%RH / ± 0.5 % FS
Mounting : Wall mountable
Power supply : 90 to 270V AC
Dimension : 100 mm W x 250 mm H x60 mm D
Weight : 640gms
Sensor : P T-100, Humidity & Pressure sensor with 2 meter cable
Model : HTP 196
Display : 3 line 4digit ,0.5” 7 segment LED
Parameter: Temperature, Humidity & Absolute or differential (pressure)
Range : 0 to 60°C / 0to100%RH / 0 to 2000mbar A or ±50pa
Resolution :0.01°C / 0.1%RH / 1mbar A
(or) 0.01pa
Accuracy : ± 0.5°C / ± 3%RH / ± 0.5 % FS
Set point: Low & High for all three Parameter
Relay: 2 relay with 5A rating with selectable parameter
Sensor : PT-100, Humidity & Temperature sensor with 2 meter cable
Operating Environment: 0 to 50°C / 20 to 95%RH Non condensing
Mounting : Wall mountable with key hole provision
Supply : 90 to 270V AC / 50Hz
Buzzer: Inbuilt
Dimension : 100 mm W x 250 mm H x60 mm D
Weight : 640gms
Model: PIJ – 541 B1
Display: 2” or 4” or 8” 6 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, PT 1000, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -199999 to 199999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.99 to 850.00°C / -327.5 to 1562.0 °F) RTD - PT 1000 (-50.0 to 400.0°C / -58.0 to 752.0 °F) TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 1000°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (option
al): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Monitoring, Data logging, Report & Graph (Optional)
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 611 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 5.5 (or) 8.5 kg
Model: PIJ – 542 A1
Display: 2” or 4” or 8” 4 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -1999 to 9999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F)
TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999.9°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Temperature drift: ≤ 0.1% FS/°C (typical 50 ppm)
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Optional
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 428 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 4.5 kg
Model : DL 98HD
Signal Input : RS 485(2 wire)
Input Protocol : Modbus RTU Slave
No. of. Channels : 32 FEATURES Ø It replace conventional 7 segment LED
Ø Up to 32 input channels display
Ø Custom selectable number of input
No size limitation- Depends upon customer channels scope(HDMI compatible TV)
Ø User configurable RS485 MODBUS setting
Ø Low cost
Ø User selectable title and Engineering units
Ø Universal indicator for any type of industrial
Ø Alarm set point and status indication process parameter Ø Adjustable display font size Ø Input from RS485 MODBUS RTU protocol
Ø Custom adjustable colour, background,
Ø HDMI output for display connectivity display, title and units
Ø OLED TV display or any type of HDMI input
Ø Inbuilt Data logging facility display device
Ø Optional Ethernet output for computer
Ø Pen drive option for Data download DISPLAY PARAMETER Temperature * Humidity * pressure * Flow & Total flow * Volume * Level * Production counting * RPM * m/min * Co2 * Volts * Current Power * pH * TDS * Conductivity, etc,. Application » Pharma industries »
Automobile industries » Power industries » Petrochemical industries Food industries
Model: FI 593
Display : 16 Character X 2 Line LCD Display
Input (factory settable): 4-20mA / 0-20mA / 0-2.5V / 0-5V / 0 - 10V / 0 - 75mV (any One)
Accuracy at 25°C: ± 0.1% of FS
Resolution : 1 / 0.1 / 0.01 (any One User Selectable)
Display Modes: Flow Rate (FR) & Total Flow (TF)
Display Range: 0 - 9999 (4 Digits) for FR , 0 - 99999999(8 Digits) for TF
Units: m³ , Liter, Gallons (Selectable)
Voltage Drop: 1 V Maximum (Applicable only for current input models)
Input Impedance: 18K Ohms (Applicable only for voltage input models)
Conversation Modes:Linear, Square Root (User Selectable)
Flow Rate Time Base: Seconds, Minutes, Hours (Selectable)
Sensor Supply: 24 V DC / 100mA Max.
Power Supply: 90 to 270 V AC
Operating Environment: 0 to 60°C / 5 to 95 % RH Non Condensing
Frequency : 50 / 60 Hz
Model : HTP-190
Display : 1 line , 4digit 0.5” , 7 segment LED
Parameter : Temperature
Range : 0 t o 60°C
Resolution : 0.0 1°C
Accuracy : ± 0.5 °C
Set point : Low & High
Relay : 1 relay with 5Arating
Weight : 520gms
Sensor : PT-100 sensor with 2 meter cable
Operating Environment: 0 to 50°C / 20 to 95%RH Non condensing
Supply : 90 to 270V AC / 50Hz
Dimension: 100 mm W x 250 mm H x60 mm D
Mounting : Wall mountable with key hole provision
Buzzer: Inbuilt
Model : HTI 197
Display : 2 line , 4 digit , 0.5’’ 7 segment LED
Parameter : Temperature & Humidity
Range : 0 to 60°C / 0 to 100%RH
Resolution : 0.01°C / 0.1%RH
Set point: Low & High for both Parameter
Accuracy : ± 0.5 °C / ± 3%RH
Relay Output ( optional) : 2 relay with 5A rating
Sensor : PT-100 & Humidity sensor with 2 meter cable
Operating Environment: 0 to 50°C / 20 to 95%RH Non condensing
Supply : 90 to 270V AC / 50Hz
Dimension : 100 mm W x 250 mm H x 60 mm D
Mounting : Wall mountable with key hole provision
Buzzer: Inbuilt
Weight : 540gms