Model: ORP 300
Display: 0.5” 3 ½ Digit 7 segment Red LED
Range: -1999 to +1999 mV
Resolution: 1 mV
Accuracy: ± 1 mV ± 1 digit
Input Impedance: > 10¹² Ohms
Input connection: BNC socket
Electrode: ORP Electrode with BNC attachment
Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing
Power supply: 230V AC / 50 Hz ± 10%
Overall Dimensions in mm: 185 x 235 x 65 (L x B x H)
Instrument weight: 1.6 kg (Approx.)
Model: TDS 602-1
Display: 4 + 4 Digit 0.5” & 0.39” 7-Segment Red LED Display
Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range)
Range (any one): 1–20 ppm, 5–200 ppm, 10–2000 ppm, 1–20 ppt, 5–200 ppt
Accuracy: ±1% of range +1 digit
Resolution: 0.01 ppm to 0.1 ppt (depends on range)
Temperature Sensor: RTD – PT100 (3-wire)
Temperature Coefficient: 0 to 3% / °C (user adjustable)
Temperature Compensation: Manual / Automatic (-20.0 to +150.0 °C)
Electrode Input: Conductivity cell on rear panel
Set Point – 1 & 2: Two set points with 6 relay status selectable
Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating
Relay Hysteresis: 0 to 500 counts (user adjustable) (only for High & Low control modes)
Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes)
Alarm Output (optional): Inbuilt audible buzzer with front-key reset
Optional Re-Tx Output: Galvanically isolated 4–20 mA
Optional Comm. Output: Isolated RS-485
Communication Protocol: MODBUS RTU
Operating Environment: -10 to 50 °C / 10 to 95% RH non-condensing
Power Supply: 90 to 270 V AC / DC, 50 Hz
Enclosure: ABS plastics
Dimension: 96 × 96 × 85 mm
Cutout Dimension: 92 × 92 mm
Weight: 350 grams (Approx.)
Model: ORT 601-1
Display: 4 + 4 Digit 0.5” & 0.39” 7-Segment Red LED Display
Range: -1999 to 1999 ORP
Accuracy: ±1 ORP ±1 digit
Resolution: 1 ORP
Electrode Input: Platinum electrode with BNC attachment
Set Point – 1 & 2: Two set points with 6 relay status selectable
Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating
Relay Hysteresis: 0 to 5 ORP (user adjustable) (only for High & Low control modes)
Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes)
Input Impedance: >10¹² ohms
Alarm Output (optional): Inbuilt audible buzzer with front-key reset
Optional Re-Tx Output: Galvanically isolated 4–20 mA
Optional Comm. Output: Isolated RS-485
Communication Protocol: MODBUS RTU
Operating Environment: -10 to 50 °C / 10 to 95% RH non-condensing
Power Supply: 90 to 270 V AC / DC, 50 Hz
Dimension: 96 × 96 × 85 mm
Cutout Dimension: 92 × 92 mm
Weight: 350 grams (Approx.)
Model: CC 603 - 1
Display: 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display
Range (any one): 1 – 20µS, 5 – 200µS, 10 to 2000µS, 1 to 20mS, 5 to 200mS
Resolution: 0.01µS to 0.1mS (depends on range)
Accuracy: ±1% of range ±1 digit
Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range)
Temperature Sensor: RTD – PT 100 (3 wire)
Temperature Co-efficient: 0 to 3% / °C (user adjustable)
Temperature Compensation: Manual / Automatic (-20.0 to +150.0°C)
Electrode Input: Conductivity cell on rear panel
Set Point – 1 & 2: Two set points with 6 relay status selectable
Relay Output:
Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating
Relay Hysteresis: 0 to 500 counts (user adjustable)
(only for High & Low control modes)
Relay Cyclic Delay: 0 to 100 seconds (user adjustable)
(only for High & Low control modes)
Alarm Output (optional): Inbuilt audible buzzer with front key reset
Optional Re-Tx Output: Galvanically isolated 4 – 20 mA
Optional Comm. Output: Isolated RS-485
Comm. Protocol: MODBUS RTU
Operating Environment: -10 to 50°C / 10 to 95% RH non-condensing
Power Supply: 90 to 270V AC / DC, 50Hz
Dimension: 96 × 96 × 85 mm
Cutout Dimension: 92 × 92 mm
Weight: 350 grams (Approx.)
Model : HTP 196
Display : 3 line 4digit ,0.5” 7 segment LED
Range : 0 to 60°C / 0to100%RH/ 0 to 2000mbarA
Resolution : 0.01 or 0.1°C / 0.1% RH / 1 mbar
Accuracy : ± 0.5 °C / ± 3%RH / ± 0.5 % FS
Mounting : Wall mountable
Power supply : 90 to 270V AC
Dimension : 100 mm W x 250 mm H x60 mm D
Weight : 640gms
Sensor : P T-100, Humidity & Pressure sensor with 2 meter cable
Model : pH 600 - 1
Display : 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display
Input Impedance : >10 Ohms
Range : -2 to 16 pH
Resolution : 0.01 pH
Temperature sensor: RTD - PT 100 (3 wire)
Temp. Compensation: Manual / Automatic (-20.0 to +150.0ºC)
Electrode Input: Combined Electrode with BNC Attachment
Accuracy : ± 0.01 pH ± 1 digit
Set Point - 1 & 2: Two Set Point with 6 Relay Status Selectable
Relay Output : Relay - 1 for Setpoint - 1, Relay - 2 for Setpoint - 2 with 5A Rating
Relay Hysteresis : 0 to 5 pH (user adjustable)(only for High & Low control modes)
Relay Cyclic delay : 0 to 100 seconds (user adjustable)(only for High & Low control modes)
Alarm Output(optional) inbuilt audible buzzer with front key reset
Optional Re. Tx. output Galvanically Isolated : 4 - 20 mA
Optional Comm. output Isolated RS 485
Comm. Protocol MODBUS RTU
Operating Environment : -10 to 50ºC / 10 to 95 % RH Non Condensing
Power Supply : 90 to 270V AC / DC 50Hz
Dimension : 96 x 96 x 85 mm.
Cutout Dimension : 92 x 92 mm
Weight : 500 grams (Approx.)
Model: PI – 541A
Display: 6 Digit 7 segment RED LED
Inputs: 0 - 20 mA, 0 to 75 mV, -10 to 10 V DC, 0 – 4000 Ω (H & L Limit Programmable)
RTD - PT 100, PT-1000, Thermocouple - J, K, R, S, T, B, N, E
Cold junction Accuracy: ± 0.3°C
Resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1°C Selectable for Analog
0.01°C for RTD and 0.1°C for TC
Unit selection: °C / °F (for RTD & TC inputs)
Linearization: Programmable custom Linearization provided (1 - 21 points)
Input signal filter: 1 – 100% user configurable
Cold junction compensation: Automatic inbuilt ‘CJC’ is provided
Relay Output* (optional): 2 Relay (5A rated) with 4 Relay Status Selection, Hysteresis, Cyclic Delay
Alarm settings: Front key settable
Alarm indication : Two LED on front panel
Re Transmission* (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC for process variable
PC communication* (optional): RS 485 (2 wire) MODBUS protocol
PC Software* (optional): Monitoring, Data logging, Report & graph
Sensor excitation Supply: 24 V DC ±10% @ 100 mA
Power supply: 90 to 270 V AC / DC / 50/60 Hz
Front panel : IP 65 protection
Operating environment: 0 to 50°C / 5 to 95% RH non condensing
Overall Dimensions: 48(H) X 96(W) X 110(D) mm
Cut out Dimension: 44(H) x 90(W) mm
Enclosure: ABS plastic
Weight: 350 grams (Approx.)
SANSEL Model TCAL 1405 / -30 Dry well Temperature calibrator are high performance for industrial and Laboratory atmosphere and covering temperature range from -30* to 100°C. Which are ideally suited onsite calibration of thermocouple, RTDs, Indicator with sensors & 4-20mA signal transmitter with sensor & indicator in Food, Pharmaceutical and all types of process industries and Calibration Laboratories. Having it’s advantage of user friendly, light weight, portable, fast settling, better uniformity and accuracy over a wide temperature range. TCAL 1405 / -30 having interchangeable inserts to suit for calibration of different diameter of sensors. Additional Inserts (optional) with special drillings are available on request.
Technical Specifications :
Model: TCAL 1405 / - 30
Temperature Range: -30* to 100°C (* @ Ambient 25 °C)
Resolution: 0.01°C
Display: 3.5“ True TFT Multi colour touch screen display
Temperature readout: °C / °F
Block Stability: ± 0.03°C
Axial Uniformity upto 40mm: ± 0.06 °C (from -30 to 50 °C), ± 0.1 °C (from 51 to 100 °C)
Radial Uniformity: ± 0.05°C
Loading Effect: ± 0.04°C
Hysteresis: ± 0.02°C
Well Dimension (dia. x height x hole depth): 25 x 145 x 130 mm
Standard well holes in mm: 6.2 x 3nos, 8.1 x 1nos
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC), 500 W
Overall Dimension in mm: 142.0 x 233.5 x 271.5 (L x B x H)(Approx.)
Instrument Weight: 8 kg (Approx.)
Model: TCAL 1501/ - 40
Display: 3.5 inch True TFT LCD Display with Touch screen
Temperature Range: -40 to 50°C
Resolution: 0.01°C
Heating & Cooling medium: ETHYLENE GLYCOL HOCH2CH2OH purity 99% (3litres) + Pure distilled water (1.5 litres ) for range from - 40 to 50 °C
Stability: ± 0.05°C
Uniformity: ± 0.2°C
Stabilization Time: 15 minutes
Heating time: 30 mins
Cooling time: 60 mins (amb. (25°C to - 40°C ) @25°C
Multi hole PP top cover: Provided for test Thermometer or sensor holding
Power supply: 230V AC 50/60Hz
Power Consumption: 1300 VA
Calibration chamber size: 90 W x 120 H x 175 D mm
Overall Dimension: 530 x 340 x 670 (L x W x H) (+155mm circulation motor) (Approx.)
Weight: 52 kg (without liquid)