Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +918048035791 (International callers) or +918048035791 (Indian callers).
Model: MTC-01
Type: R, S
Temperature Range:
(a) 200 to 1500°C
(b) 100 to 1200°C
Accuracy: Class 1 (0.6°C or 0.1% of Temperature which ever is greater)
Temperature Scale: ITS-90
Sheath Material: K-99 grade ceramic
Thermocouple wire dia: 0.5mm
Probe dia & Length: 6mm OD & 450mm Length
Cable Length: 1.5 meter long with male female, Miniature Omega connector
Handle Dimension: 20mm OD & 100mm Length
Calibration Certified: ISO/IEC 17025 Accredited 5 point
“SANSEL” Series BCAL 1502 is a Micro controller Based Precision Temperature Calibrators Generates True Reference Temperature. The Temperature Controller of the Calibrators Uses a Auto Tune PID Control Algorithm. Infra red thermometer & online pyrometer calibration is performed by comparison of the temperature measured by UUC and target temperature indicated by the calibrator or using standard pyrometer. Focus the Unit Under Calibration (UUC) to be Calibrate to the target point given in BCAL 1502. Set the Temperature from the Touch screen display. Both True and set Temperature can be read. When Stabilization Occurs, Simply Read the Temperature and re-Calibrate the UUC.
Model: BCAL 1502
Display: 4.3 inch True TFT LCD Display with Touch screen
Temperature Range: 500 to 1500 °C
Resolution: 0.1°C
Stability: ± 1°C
Radial Uniformity: ± 1% of reading
Bath Temperature Control: Digital Temperature Controller with Auto Tune PID Algorithm
Temperature readout: °C
Aperture area: 30mm
Emissivity: 0.950
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption: 4 KVA
Dimension (W*D*H) (Approx.): 580mm W x 450mm D x 390mm H
Instrument Weight (Approx): 45 kg
Model: TCAL 1501 / 300
Display: 4.3 inch True TFT LCD Display with Touch screen
Temperature Range : Amb. to 300°C
Resolution: 0.01°C
Stability: ± 0.03°C
Radial uniformity: Better than ± 0.2°C
Measure inputs: RTD-PT 50, 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms
Temperature Readout: C
Stabilization Time: 15 minutes
Heating time: 30 mins (25 to 600°C)
Cooling time: 50 mins (600 to 100°C )
Well Dimension: 30 x 150 mm (dia x height)
Test sensor immersion depth: 140 mm
Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1
PC Interface (optional): RS 232 with automatic calibration software
UUC Sensor supply output: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (optional 110V AC)
Power Consumption: 1200 VA
Switch test: Provided
Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.)
Weight: 8.5 kg (without well insert) (Approx.)
Model: Tcal 1501 / -80
Display: 4.3 inch true TFT display with touch screen
Working Range: -80 to -40 °C
Resolution: 0.01 °C
Stability: ± 0.03 °C
Uniformity: ± 0.2 °C
Bath Temperature Control: Digital Temperature Controller with FUZZY PID
Multi Hole Well: Provided for Different type of Sensors, Sensor with Indicator & Thermometer Calibration
Cooling medium: IPA
Liquid Capacity: 5 Liters
Testing Area: 100mm W x 100mm H x 190mm D
Over all Dimension: 705mm L x 505mm W x 825mm H
Power Supply: 230V AC ± 10% / 50Hz (Optional 110V44 AC)
Weight: 80 kg (approx.)
Model: PCAL 1300 / 30 bar
Range (bar): -0.9 to 30 bar
Pressure media: Air
Pressure pump: PVP – 02
Display: 128 × 64 COG Graphic LCD with White LED Backlight
Instrument port (at pump): 3/8“ BSP Female
Test Port (at pump): ¼” BSP Female
Pump dimension in mm (Approx.): 230 × 140 × 65 mm (L × B × H)
Resolution (bar): 6 digit user selectable
Instrument Port: 3/8” BSP Male
Instrument dimension: 100 × 100 × 55 (W × H × D) mm
Instrument Weight: 400gms (Approx.)
Stability time: 1 to 2 mins
Accuracy: ± 0.05% FS
Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero: One touch zero provided on front key
Pressure Peak: Maximum & minimum with user reset option
Pressure overflow: FS X 2 (Max.)
Pressure burst: FS X 3 (Max.)
Temp.Measure: RTD -PT 100 (2,3,4, wire selectable)
Temp. Range: -199.999 to 850.000
mA Measure: 0-24 mA (scalable)
Display scale: -99999 to 99999 counts (for mA measure input)
Switch test: Provided
Display hold: One touch hold provided on front key
Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
PC Software (optional): Windows-based semi-automatic calibration software (Optional)
Pump weight (gms) (Approx.): 750 gms
Model: Pcal 1300 / 350 bar
Range (bar): 0 to 350 bar
Pressure media: Oil & Water
Pressure pump: HPP – 01
Display: 128 × 64 COG Graphic LCD with White LED Backlight
Test Port (at pump): ¼” BSP Female
Instrument port (at pump): 3/8” BSP Female
Instrument Port: 3/8” BSP Male
Pump dimension in mm (Approx.): 240 × 185 × 95 mm (H × W × D)
Resolution (bar): 6 digit user selectable
Instrument dimension: 100 × 100 × 55 (W × H × D) mm
Instrument Weight: 400 gms (Approx.)
Stability time: 1 to 2 mins
Accuracy: ± 0.05% FS
Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, cmH₂O, mmH₂O
Pressure Zero: One touch zero provided on front key
Pressure Peak: Maximum & minimum with user reset option
Pressure overflow: FS X 2 (Max.)
Pressure burst: FS X 3 (Max.)
Temp.Measure: RTD - PT 100 (2,3,4, wire selectable)
Temp. Range: -199.999 to 850.000
mA Measure: 0-24 mA (scalable)
Display scale: -99999 to 99999 counts (for mA measure input)
Switch test: Provided
Display Hold: One touch hold provided on front key
Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
Pump Weight (gms) (Approx.): 1.26 kg
Switch test: Provided
Display Hold: One touch hold provided on front key
PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
PC Software (optional): Windows-based semi-automatic calibration software (optional)
Model: Pcal 1300 / 1000 bar
Range (bar): 0 to 1000 bar
Pressure media: Oil & Water
Pressure pump: CT – 02
Display: 128 × 64 COG Graphic LCD with White LED Backlight
Resolution (bar): 6 digit user selectable
Instrument Port: ½” BSP Male x 10 mm long
Instrument dimension: 100 × 100 × 55 (W × H × D) mm
Instrument Weight: 400 gms (Approx.)
Stability time: 1 to 2 mins
Accuracy: ± 0.05% FS
PSI: 17400 Psi
Over pressure: 120%
Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero: One touch zero provided on front key
Pressure Peak: Maximum & minimum with user reset option
Pressure overflow: FS X 2 (Max.)
Pressure burst: FS X 3 (Max.)
Temp.Measure: RTD - PT 100 (2,3,4, wire selectable)
Temp. Range: -199.999 to 850.000
mA Measure: 0-24 mA (scalable)
Display scale: -99999 to 99999 counts (for mA measure input)
Switch test: Provided
Display Hold: One touch hold provided on front key
Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
Pump Weight (Approx.): 14 kg
PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
PC Software (optional): Windows-based semi-automatic calibration software (Optional)
Model : PCAL 1300 / 2 bar
Range (bar) : −0.9 to 2 bar
Pressure Media : Air
Pressure Pump : PVP – 01, 02
Display : 128 × 64 COG Graphic LCD with White LED Back Light
Instrument Port (at Pump) : 3/8” BSP Female
Test Port (at Pump) : ¼” BSP Female
Instrument Port : 3/8” BSP Male
Pump Dimension in mm (Approx.) : PVP – 01 (230 × 220 × 70 mm (H × W × D)), PVP – 02 (230 × 140 × 65 mm (L × B × H))
Resolution (bar) : 6 Digit User Selectable
Instrument Port (Extended) : ¼” BSP Male × 10 mm Long
Instrument Dimension : 100 × 100 × 55 (W × H × D) mm
Instrument Weight : 400 gms (Approx.)
Stability Time : 1 to 2 mins
Accuracy : ± 0.05% FS
Pressure Units (Selectable)* : bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero : One Touch Zero Provided on Front Key
Pressure Peak : Maximum & Minimum with User Reset Option
Pressure Overflow : FS × 2 (Max.)
Pressure Burst : FS × 3 (Max.)
Temperature Measure : RTD – PT100 (2, 3, 4 Wire Selectable)
Temperature Range : −199.999 to 850.000
mA Measure : 0–24 mA (Scalable)
Display Scale : −99999 to 99999 Counts (for mA Measure Input)
Switch Test : Provided
Display Hold : One Touch Hold Provided on Front Key
Power Supply : 9 V DC ±5% / 600 mAh Rechargeable Battery with Battery Life 20 Hours without Backlight (or) 9 V DC Adapter / 230 V AC Supply Operated
Pump Weight (gms) (Approx.) : PVP – 01 (1.1 kg), PVP – 02 (750 gms)
PC Interface (Optional) : RS-485 (2 Wire) (Note: Connect to PC using USB to RS-485 Converter Supplied along with PC Software)
PC Software (Optional) : Windows Based Semi-Automatic Calibration Software (Optional)
Model : PCAL 1300 / 1 (Pneumatic)
Display : 128 × 64 COG Graphic LCD with White LED Back Light
Range (bar) : −0.9 to 1 bar
Pressure Media : Air
Resolution (bar) : 6 Digit User Selectable
Accuracy : ± 0.05% FS
Pressure Pump : PVP – 01
Instrument Port (at Pump) : 3/8” BSP Female
Test Port (at Pump) : ¼” BSP Female
Instrument Port : 3/8” BSP Male
Pump Dimension in mm (Approx.) : 230 × 220 × 70 (H × W × D)
Instrument Dimension in mm : 100 × 100 × 55 (W × H × D)
Instrument Weight : 400 gms (Approx.)
Stability Time : 1 to 2 mins
Pressure Units (Selectable)* : bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero : One Touch Zero Provided on Front Key
Pressure Peak : Maximum & Minimum with User Reset Option
Pressure Overflow : FS × 2 (Max.)
Pressure Burst : FS × 3 (Max.)
Temperature Measure : RTD – PT100 (2, 3, 4 Wire Selectable)
Temperature Range : −199.999 to 850.000
mA Measure : 0–24 mA (Scalable)
Display Scale : −99999 to 99999 Counts (for mA Measure Input)
Switch Test : Provided
Display Hold : One Touch Hold Provided on Front Key
Power Supply : 9 V DC ±5% / 600 mAh Rechargeable Battery with Battery Life 20 Hours without Backlight (or) 9 V DC Adapter / 230 V AC Supply Operated
PC Interface (Optional) : RS-485 (2 Wire) (Note: Connect to PC using USB to RS-485 Converter Supplied along with PC Software)
PC Software (Optional) : Windows Based Semi-Automatic Calibration Software (Optional)
Model: Pcal 1300 / ± 350 mbar
Range (bar): ± 350 mbar
Pressure media: Air
Pressure pump: PVP – 01
Display: 128 × 64 COG Graphic LCD with White LED Backlight
Test Port (at pump): ¼” BSP Female
Instrument port (at pump): 3/8” BSP Female
Instrument Port: 3/8” BSP Male
Pump dimension in mm (Approx.): 230 × 220 × 70 mm (H × W × D)
Resolution (bar): 6 digit user selectable
Instrument dimension: 100 × 100 × 55 (W × H × D) mm
Instrument Weight: 400 gms (Approx.)
Stability time: 1 to 2 mins
Accuracy: ± 0.05% FS
Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, cmH₂O, mmH₂O
Pressure Zero: One touch zero provided on front key
Pressure Peak: Maximum & minimum with user reset option
Pressure overflow: FS X 2 (Max.)
Pressure burst: FS X 3 (Max.)
Temp.Measure: RTD - PT 100 (2,3,4, wire selectable)
Temp. Range: -199.999 to 850.000
mA Measure: 0-24 mA (scalable)
Display scale: -99999 to 99999 counts (for mA measure input)
Switch test: Provided
Display Hold: One touch hold provided on front key
Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
Pump Weight (gms) (Approx.): 1.1 kg
PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
PC Software (optional): Windows-based semi-automatic calibration software (optional)