Display : 3 line 4digit ,0.5” 7 segment LED
Parameter: Temperature, Humidity & Absolute or differential (pressure)
Range : 0 to 60°C / 0to100%RH / 0 to 2000mbar A or ±50pa
Resolution :0.01°C / 0.1%RH / 1mbar A
(or) 0.01pa
Accuracy : ± 0.5°C / ± 3%RH / ± 0.5 % FS
Set point: Low & High for all three Parameter
Relay: 2 relay with 5A rating with selectable parameter
Sensor : PT-100, Humidity & Temperature sensor with 2 meter cable
Operating Environment: 0 to 50°C / 20 to 95%RH Non condensing
Mounting : Wall mountable with key hole provision
Supply : 90 to 270V AC / 50Hz
Buzzer: Inbuilt
Dimension : 100 mm W x 250 mm H x60 mm D
Weight : 640gms
Model: PIJ – 541 B1
Display: 2” or 4” or 8” 6 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, PT 1000, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -199999 to 199999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.99 to 850.00°C / -327.5 to 1562.0 °F) RTD - PT 1000 (-50.0 to 400.0°C / -58.0 to 752.0 °F) TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 1000°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (option
al): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Monitoring, Data logging, Report & Graph (Optional)
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 611 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 5.5 (or) 8.5 kg
Model: PIJ – 542 A1
Display: 2” or 4” or 8” 4 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -1999 to 9999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F)
TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999.9°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Temperature drift: ≤ 0.1% FS/°C (typical 50 ppm)
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Optional
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 428 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 4.5 kg
Model : DL 98HD
Signal Input : RS 485(2 wire)
Input Protocol : Modbus RTU Slave
No. of. Channels : 32 FEATURES Ø It replace conventional 7 segment LED
Ø Up to 32 input channels display
Ø Custom selectable number of input
No size limitation- Depends upon customer channels scope(HDMI compatible TV)
Ø User configurable RS485 MODBUS setting
Ø Low cost
Ø User selectable title and Engineering units
Ø Universal indicator for any type of industrial
Ø Alarm set point and status indication process parameter Ø Adjustable display font size Ø Input from RS485 MODBUS RTU protocol
Ø Custom adjustable colour, background,
Ø HDMI output for display connectivity display, title and units
Ø OLED TV display or any type of HDMI input
Ø Inbuilt Data logging facility display device
Ø Optional Ethernet output for computer
Ø Pen drive option for Data download DISPLAY PARAMETER Temperature * Humidity * pressure * Flow & Total flow * Volume * Level * Production counting * RPM * m/min * Co2 * Volts * Current Power * pH * TDS * Conductivity, etc,. Application » Pharma industries »
Automobile industries » Power industries » Petrochemical industries Food industries
Model: TCAL 1404/500
Display: 2.8" True TFT with Touch screen
Temperature Range: Amb. + 5 to 500 °C
Radial uniformity: (Better than) ±0.05°C
Resolution: 0.01 °C
Stability: ±0.08 °C
Temperature readout: °C
Heating time: Amb to 500 --> 25 min
Cooling time: 500 to 50--> 1 hr 20 min
Stabilization time: 15 mins
Well Dimension(dia. x height): 20 x 100 mm
Well immersion depth: 90 mm
Standard well holes in mm: 6.2 x 2nos
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power consumption: 350 w
Overall Dimension in mm: 170 x 95 x 183 mm
Instrument Weight: 3.75 Kg
Model: TCAL 1404/300
Display: 2.8" True TFT with Touch screen
Temperature Range: Amb. + 5 to 300 °C
Radial uniformity: (Better than) ±0.03°C
Resolution: 0.01 °C
Stability: ±0.04 °C
Temperature readout: °C
Heating time: Amb to 300 -->23 min
Cooling time: 300 to 50-->30 min
Stabilization time: 15 mins
Well Dimension(dia. x height): 20 x 100 mm
Well immersion depth: 90 mm
Standard well holes in mm: 6.2 x 2nos
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power consumption: 250 w
Overall Dimension in mm: 170 x 95 x 183 mm
Instrument Weight: 2.75 Kg
Model TCAL: 1404/-15
Display: 2.8' True TFT with Touch screen
Temperature Range: -15 to 120 °C
Radial uniformity: (Better than) ±0.03°C
Resolution: 0.01 °C
Stability: ±0.03 °C
Temperature readout: °C
Heating time: Amb to 120-->25 min, -15 to Amb -->5 min
Cooling time: Amb to -15 -->20 min, 120 to 50 -->8 min
Stabilization time: 10 mins
Well Dimension(dia. x height): 20 x 90 mm
Well immersion depth: 90 mm (throw hole)
Standard well holes in mm: 6.2 x 2nos
Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz
Power consumption: 100 w
Overall Dimension in mm: 170 x 95 x 183 mm
Instrument Weight: 3.5 Kg
Model: TCAL 1404/-5
Display: 2.8' True TFT with Touch screen
Temperature Range: -5 to 100°C
Radial uniformity: (Better than) ±0.03°C
Resolution: 0.01 °C
Stability: ±0.03 °C
Temperature readout: °C
Heating time: Amb to 100-->15min, -5 to Amb -->3 min
Cooling time: Amb to -5 -->15min, 100 to 50-->4 min
Stabilization time: 10 mins
Well Dimension(dia. x height): 20 x 90 mm
Well immersion depth: 90 mm (throw hole)
Standard well holes in mm: 6.2 x 2nos
Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz
Power consumption: 100 w
Overall Dimension in mm: 170 x 95 x 183 mm
Instrument Weight: 3.5 Kg
We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABLNABL)national accreditation board for testing and calibration laboratories from Chennai, Tamil Nadu, India.
Very Low Pressure ± 25 mbar
Type of Instruments Calibrated
Manometer
Low pressure Transducer/Transmitter
Gauges
Differential Pressure Indicator/Tranmitter
Pressure Data Logger
Pressure switch
Low pressure Calibrators,etc.,
Absolute Pressure: 0.60 bar to 2 bar
Type of Instruments Calibrated
Barometers
Aneroid barometer
Absolute gauges
Absolute pressure sensor/Tranmitter
Absolute pressure indicator/ controller
Logger and Calibrators etc
Vacuum: -0.1 bar to -0.99 bar
Type of Instruments Calibrated
Vacuum Gauge
Vacuum Tranduer/Transmitter
Vacuum Indicator/Controller/Switch
Vacuum Logger
Calibrators etc.,
Pressure(Hydraulic and Pneumatic) 1 bar to 1000 bar and 0.1 bar to 35 bar
Type of Instruments Calibrated
Pressure Calibrators
Pressure Transducer
Pressure Transmitter
Digital Pressure Gauges
Pressure Controller
Pnueumatic pressure gauges
Hydraulic Pressure gauges
Differential pressure indicators, etc.,
Mass/Weight 1 mg to 50 kg
Type of Instruments Calibrated(Accuracy class: E2,F1,F2,M1,M2,ETC.,)
Standard weight box
Weights, etc.,
Weighing Scale and Balance 1mg to 300 Kg
Micro balance
Analytical balance
Digital balance
Weighing Scale
Volume 1µl to 5l
Type of Instruments Calibrated
Pipette
Burette
Flask
beaker
We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India.
Voltage : 1 mV to 1000 V AC/DC
Current : 10 µA to 1000 A AC/DC
TC, RTD : PT-100,J,K,R,S,T,E,B,N
Resistance : 1 ohm to 100 G ohm
Frequency : 1 Hz to 10 MHz
Capacitance : 10 nF to 1 µF
Type of Instruments Calibrated
Multi Product Calibrator
Multi Function Calibrator
Digital Multimeter
Frequency Counter
Signal Generator
Decade Resistance Box
Meggar
Power Supplies
Analog Voltmeter/Ammeter
Digital Voltmeter/Ammeter
AC/DC Clamp meter
Temperature Indicator/controller
I/P,P/I Convertor
Valve Positioner
Process Flow Indicator
LCR Meter
Process Flow Totalizer, etc.,
High Voltage 1 kV to 30 kV
Type of Instruments Calibrated
AC/DC High Voltage source
Timer 1s to 99999s
Type of Instruments Calibrated
Digital Timer
Analog Timer
Stop Watch, etc.,
Note: Price May vary based on quantity and instruments
We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India.
Temperature(Contact) Range from -80 deg C to 1500 deg c
Type of Instruments Calibrated:
Digital Thermometer
Glass Thermometer
Dry block Calibrators
Thermocouple and RTD probes
Thermistors
Temperature Recorder
Temperature Scanner/Data logger
Temperature Indicator with sensor
Temperature Gauge
Temperature Transmitter
Temperature bath,etc.,
Mapping and Validation for single or multi point
Freezer
incubator
oven
furnance
Storage rooms
clean rooms
dryer
cold rooms
Environmental chambers
Humidity Indicator/chamber, etc.,
Temperature(Non-Contact)Range from 0 deg c to 1500 deg c
Type of Instruments Calibrated
Non-Contact Pyrometers
IR thermometer
Black Body Source, ect.,
Humidity: Range from 5 to 60 deg c & 10 to 95%
Type of Instruments Calibrated
Humidity sensors/Transmitter
Humidity/Temperature logger
Analog hygrometer
Model: FI 593
Display : 16 Character X 2 Line LCD Display
Input (factory settable): 4-20mA / 0-20mA / 0-2.5V / 0-5V / 0 - 10V / 0 - 75mV (any One)
Accuracy at 25°C: ± 0.1% of FS
Resolution : 1 / 0.1 / 0.01 (any One User Selectable)
Display Modes: Flow Rate (FR) & Total Flow (TF)
Display Range: 0 - 9999 (4 Digits) for FR , 0 - 99999999(8 Digits) for TF
Units: m³ , Liter, Gallons (Selectable)
Voltage Drop: 1 V Maximum (Applicable only for current input models)
Input Impedance: 18K Ohms (Applicable only for voltage input models)
Conversation Modes:Linear, Square Root (User Selectable)
Flow Rate Time Base: Seconds, Minutes, Hours (Selectable)
Sensor Supply: 24 V DC / 100mA Max.
Power Supply: 90 to 270 V AC
Operating Environment: 0 to 60°C / 5 to 95 % RH Non Condensing
Frequency : 50 / 60 Hz