Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108048035791 (International callers) or 08048035791 (Indian callers).
Descriptions:
Measurement of relevant climatic data is becoming more and more important. This Humidity & Temperature Indicator offer very accurate measurement of Relative Humidity and Temperature by Excellent readability of the very high intensity seven segment LED display.
The Humidity & Temperature Indicator housed with roughest case allow the use in tough industrial environments, Latest technology and well proven sensor guaranteed highest accuracy and long term stable measurement.
Model : HT 191J
Display : 4+4 Digit 2' or 4' or 8' Seven Segment LED Display
Range : 0-60°C 0-100%RH (Depends on Sensor)
Resolution : 0.1 or 0.01 C / 0.1% RH
Accuracy : Depends on Sensor
Mounting : Wall Mountable
Operating Temp.& Humd : 0-50°C/20 to 95% RH Non Condensing
Power Supply : 230V AC 50Hz
Weight : 5kg (Approx..)
Model: PIJ – 541 B1
Display: 2” or 4” or 8” 6 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, PT 1000, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -199999 to 199999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.99 to 850.00°C / -327.5 to 1562.0 °F) RTD - PT 1000 (-50.0 to 400.0°C / -58.0 to 752.0 °F) TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 1000°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (option
al): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Monitoring, Data logging, Report & Graph (Optional)
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 611 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 5.5 (or) 8.5 kg
Model: PIJ – 542 A1
Display: 2” or 4” or 8” 4 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -1999 to 9999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F)
TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999.9°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Temperature drift: ≤ 0.1% FS/°C (typical 50 ppm)
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Optional
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 428 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 4.5 kg
Model : DL 98HD
Signal Input : RS 485(2 wire)
Input Protocol : Modbus RTU Slave
No. of. Channels : 32 FEATURES Ø It replace conventional 7 segment LED
Ø Up to 32 input channels display
Ø Custom selectable number of input
No size limitation- Depends upon customer channels scope(HDMI compatible TV)
Ø User configurable RS485 MODBUS setting
Ø Low cost
Ø User selectable title and Engineering units
Ø Universal indicator for any type of industrial
Ø Alarm set point and status indication process parameter Ø Adjustable display font size Ø Input from RS485 MODBUS RTU protocol
Ø Custom adjustable colour, background,
Ø HDMI output for display connectivity display, title and units
Ø OLED TV display or any type of HDMI input
Ø Inbuilt Data logging facility display device
Ø Optional Ethernet output for computer
Ø Pen drive option for Data download DISPLAY PARAMETER Temperature * Humidity * pressure * Flow & Total flow * Volume * Level * Production counting * RPM * m/min * Co2 * Volts * Current Power * pH * TDS * Conductivity, etc,. Application » Pharma industries »
Automobile industries » Power industries » Petrochemical industries Food industries
Model: PIJ – 542 A1
Display: 2” or 4” or 8” 4 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -1999 to 9999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F)
TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999.9°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Temperature drift: ≤ 0.1% FS/°C (typical 50 ppm)
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Optional
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 428 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 4.5 kg
Model: PIJ – 542 C1
Display: 2” or 4” or 8” 4 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -1999 to 9999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F)
TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999.9°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Optional
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 760 x 320 x 85 (or) 1125 x 320 x 85 (L x H x D) in mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 7.5 (or) 8.5 kg
Model : HTP 196
Display : 3 line 4digit ,0.5” 7 segment LED
Parameter: Temperature, Humidity & Absolute or differential (pressure)
Range : 0 to 60°C / 0to100%RH / 0 to 2000mbar A or ±50pa
Resolution :0.01°C / 0.1%RH / 1mbar A
(or) 0.01pa
Accuracy : ± 0.5°C / ± 3%RH / ± 0.5 % FS
Set point: Low & High for all three Parameter
Relay: 2 relay with 5A rating with selectable parameter
Sensor : PT-100, Humidity & Temperature sensor with 2 meter cable
Operating Environment: 0 to 50°C / 20 to 95%RH Non condensing
Mounting : Wall mountable with key hole provision
Supply : 90 to 270V AC / 50Hz
Buzzer: Inbuilt
Dimension : 100 mm W x 250 mm H x60 mm D
Weight : 640gms