Calibrators

SANSEL Model BCAL 40, Black body Calibrator is used to measure the accuracy and performance of non-contact fever detection systems, like medical thermometer & image scanner. Now it is being used in relation to COVID-19 (corona virus). This Blackbody Source meets the demand for a simple cost effective solution but high accurate device for the calibration of thermal imager and IR thermometers that are used at temperature around that of the human body. Unlike Heat only devices, This model uses a solid state Heat & cool Technology, so that this can be generate both Heat and Cool. This having benefits to maintain the block temperature in different ambient temperature. BCAL 40 using True colour 3.5” Touch screen display, easy to read multi parameter at the same time like Block temperature, Set temperature, Control status, Output % level, range of the equipment, displays both °C & °F and two Touch screen soft keys are used for settings and one more advantage of help menu to guide the operating Instruction of the equipment. Hence no need of hard copy of Instruction manual. Model: BCAL 40 Display: 3.5 inch True TFT LCD Display with Touch screen Temperature Range: Body mode: 20 to 50°C / 68 to 122°F, Surface mode: 0 to 100°C / 32 to 212°F Resolution : 0.01°C Stability: ± 0.03°C Uniformity: ± 0.3°C Stabilization Time: 10 minutes Temperature readout: °C & °F at a time Heating time: 10 mins (Amb. To 50°C ) Power supply: 90 to 260V AC/DC / 50/60Hz Power Consumption: Less than 100 VA Aperture area: 25mm Emissivity: 0.950 Overall Dimension: 210 x 210 x 140 (L x B x H)(Approx.) Instrument Weight: 3.7 kg

68179d65be22ee500d53ff54 Card 2

product image
Analytical Instruments

Model: pH 302 Display: 16 Character x 2 line LCD with Backlight Range: 0 to 14 pH / -1999 to +1999 mV /0 – 150°C Resolution: 0.01 pH / 1 mV / 0.1°C Accuracy: ± 0.01 pH ± 1 digit / ± 1 mV ± 1 digit /± 0.5°C ± 1 digit Input Impedance: > 10¹² Ohms Temperature Compensation: 0 to 150°C Manual / Automatic Electrode: Combined pH Electrode with BNC attachment Temperature sensor: Provided with 3 pin female socket pH / ORP Input connection: BNC socket Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing Temperature connection: 3 pin male socket Power supply: 230V AC / 50 Hz ± 10% Overall Dimensions in mm: 190 x 185 x 75 ( L x B x H ) Instrument weight: 1.7 kg (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Analytical Instruments

Model: TDS 100 Display: 0.5” 3 ½ Digit 7 segment Red LED Range: 0 – 20 ppm/ 200 ppm/ 2000 ppm/ 20ppt / 200ppt ( 5 range selection using front rotary switch ) Resolution: 0.01 / 0.1 / 1 for ppm range & 0.01 / 0.1 for ppt range Accuracy: ± 1 % of Range ± 1 digit Temperature Compensation: 0 to 50°C (Manual) continuously adjustable Cell Constant: Adjustable with indication on display Sensor: Platinum Conductivity cell (1.0 cell constant) with Banana male connector Input Connection: Banana socket Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing Power supply: 230V AC / 50 Hz ± 10% Overall Dimensions in mm: 185 x 235 x 65 ( L x B x H ) Instrument weight: 1.6 kg (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Analytical Instruments

Model: pH 300 Display: 0.5” 3 ½ Digit 7 segment Red LED Range: 0 to 14 pH / -1999 to +1999 mV Resolution: 0.01 pH / 1 mV Accuracy: ± 0.05 pH ± 1 digit / ± 1 mV ± 1 digit Input Impedance: > 10¹² Ohms Input connection: BNC socket Electrode: Combined Electrode with BNC attachment Temperature Compensation: 0 to 50°C (Manual) continuously adjustable Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing Power supply: 230V AC / 50 Hz ± 10% Overall Dimensions in mm: 185 x 235 x 65 (L x B x H) Instrument weight: 1.6 kg (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Analytical Instruments

Model : CC 100 Display : 0.5” 4 Digit 7 segment Red LED Range :0 to 9999 counts Input : Count Pulse for Electronic Marker Pen Resolution : 1 count Disk Diameter : 110 mm Magnification : x1.7 Surface Count Reset : Push Button Provided on front panel Input connection : 2 Pin Female Socket Operating Environment : 0 to 50 °C / 20 to 95 % RH non condensing Power supply : 230V AC / 50 Hz ± 10% Overall Dimension in mm : 220 x 200 x 105 (L x B x H) Instrument Weight : 2.5 kg (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Analytical Instruments

Model: DCM 200 Display: 0.5” 3 ½ Digit 7 segment Red LED Range: 0 – 20 μS/ 200 μS/ 2000 μS/ 20 mS / 200 mS ( 5 range selection using front rotary switch ) Resolution: 0.01 / 0.1 / 1 for μS range & 0.01 / 0.1 for mS range Accuracy: ± 1 % of Range ± 1 digit Temperature Compensation: 0 to 50°C (Manual) continuously adjustable Cell Constant: Adjustable with indication on display Sensor: Platinum Conductivity cell (1.0 cell constant) with Banana male connector Input Connection: Banana socket Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing Power supply: 230V AC / 50 Hz ± 10% Overall Dimensions in mm: 185 x 235 x 65 ( L x B x H ) Instrument weight: 1.6 kg (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Master Indicators

Model: HTD 200 Display: 2.8” True colour TFT display with touch screen Range: Temperature: -40 to 85 °C (T), Humidity: 0 to 100% RH (RH) Resolution: 0.01 °C / 0.01 % RH Accuracy at 23 °C± 5 °C : ± 0.2 °C / ±0.8 % RH Psychometric calculated indication: Dew / Frost point ( Dp / Fp ) Wet Bulb Temperature ( Tw ) Vapour partial pressure ( E ) Vapour Saturation pressure ( Ew ) Mixing ratio by weight (dry) ( g / kg ) Enthalpy ( H ) ( KJ / kg ) Specific Humidity (moisture) ( g / kg ) Absolute Humidity (moisture) ( g / m³ ) Volume mixing ratio (dry) ( ppm ) Calculation method: WMO method Display refresh rate: 1 s (typical) Calibration : 5 point lookup table for both Temperature & Humidity Alarm: Audible & Visible user settable individual High & Low alarm set with alarm mode selection for all the 3 parameters Touch sound: On / Off option available Logging interval: 1 sec to 24 Hrs programmable Memory capacity: 4 to 32 GB Internal storage Data download: Via USB Battery charging port: USB C type Integrated battery: 3.7V / 10,000 mAh Inbuilt rechargeable polymer Li-ion battery Backlight time interval: 0(OFF) to 59 mins : 59 secs (user adjustable) Brightness adjustment: 10 to 100% (user adjustable) Application environment range: -10 to 60 °C / 0 to 100% RH (non condensed) Storage environment range: -10 to 45 °C / 10 to 90% RH Housing material: ABS with anti-slip grip silicon cover Protection class: IP40 Overall Dimension in mm: 35 x 80 x 165 mm ( L x B x H) Instrument Weight: 560 g (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : TCAL 1503 / -35 Display : 4.3” True colour TFT display with touch screen Temperature Range : -35 to 120 °C @ 23 °C Ambient Resolution : 0.01 °C Block Stability : Better than ± 0.03°C at full range Block Radial Uniformity : ± 0.02°C at full range Block Axial Uniformity (upto 40mm) : ± 0.20°C at -35°C ± 0.05°C at 0°C ± 0.05°C at 50°C ± 0.17°C at 100°C Loading effect: Better than ± 0.08°C Hysteresis: Better than ± 0.03°C Heating time: 25 mins (25 to 120 °C) 75 mins (-35 to 120 °C) 52 mins (-35 to 25 °C) Cooling time: 25 mins (25 to -35 °C) 15 mins (25 to -30 °C) 65 mins (120 to 25 °C) Stabilization Time : 10 minutes Test sensor immersion depth: 130 mm Standard well holes in mm : Insert No. 1 →5.1, 6.2, 6.2 & 8.1, Insert No. 2 →6.2, 6.2 & 10.2 Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms Cold junction Accuracy: ± 0.3°C UUC Sensor supply input: 24V DC ± 10% / 50mA max. Switch Test : Provided Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption : 500 VA Overall Dimension in mm : 390 x 185 x 356 (L x B x H)(Approx.) Instrument Weight : 17.3 kg (with well insert)(Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501/ - 40 Display: 3.5 inch True TFT LCD Display with Touch screen Temperature Range: -40 to 50°C Resolution: 0.01°C Heating & Cooling medium: ETHYLENE GLYCOL HOCH2CH2OH purity 99% (3litres) + Pure distilled water (1.5 litres ) for range from - 40 to 50 °C Stability: ± 0.05°C Uniformity: ± 0.2°C Stabilization Time: 15 minutes Heating time: 30 mins Cooling time: 60 mins (amb. (25°C to - 40°C ) @25°C Multi hole PP top cover: Provided for test Thermometer or sensor holding Power supply: 230V AC 50/60Hz Power Consumption: 1300 VA Calibration chamber size: 90 W x 120 H x 175 D mm Overall Dimension: 530 x 340 x 670 (L x W x H) (+155mm circulation motor) (Approx.) Weight: 52 kg (without liquid)