Coimbatore
08048127335
+917299972093

Items tagged with 'sub zero temperature probe calibration'

68179d65be22ee500d53ff54 Card 2

product image
NABL accreditated laboratory

We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India. Temperature(Contact) Range from -80 deg C to 1500 deg c Type of Instruments Calibrated: Digital Thermometer Glass Thermometer Dry block Calibrators Thermocouple and RTD probes Thermistors Temperature Recorder Temperature Scanner/Data logger Temperature Indicator with sensor Temperature Gauge Temperature Transmitter Temperature bath,etc., Mapping and Validation for single or multi point Freezer incubator oven furnance Storage rooms clean rooms dryer cold rooms Environmental chambers Humidity Indicator/chamber, etc., Temperature(Non-Contact)Range from 0 deg c to 1500 deg c Type of Instruments Calibrated Non-Contact Pyrometers IR thermometer Black Body Source, ect., Humidity: Range from 5 to 60 deg c & 10 to 95% Type of Instruments Calibrated Humidity sensors/Transmitter Humidity/Temperature logger Analog hygrometer

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : TCAL 1503 / -35 Display : 4.3” True colour TFT display with touch screen Temperature Range : -35 to 120 °C @ 23 °C Ambient Resolution : 0.01 °C Block Stability : Better than ± 0.03°C at full range Block Radial Uniformity : ± 0.02°C at full range Block Axial Uniformity (upto 40mm) : ± 0.20°C at -35°C ± 0.05°C at 0°C ± 0.05°C at 50°C ± 0.17°C at 100°C Loading effect: Better than ± 0.08°C Hysteresis: Better than ± 0.03°C Heating time: 25 mins (25 to 120 °C) 75 mins (-35 to 120 °C) 52 mins (-35 to 25 °C) Cooling time: 25 mins (25 to -35 °C) 15 mins (25 to -30 °C) 65 mins (120 to 25 °C) Stabilization Time : 10 minutes Test sensor immersion depth: 130 mm Standard well holes in mm : Insert No. 1 →5.1, 6.2, 6.2 & 8.1, Insert No. 2 →6.2, 6.2 & 10.2 Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms Cold junction Accuracy: ± 0.3°C UUC Sensor supply input: 24V DC ± 10% / 50mA max. Switch Test : Provided Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption : 500 VA Overall Dimension in mm : 390 x 185 x 356 (L x B x H)(Approx.) Instrument Weight : 17.3 kg (with well insert)(Approx.)

68179d65be22ee500d53ff54 Card 2

product image
NABL accreditated laboratory

We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India. Voltage : 1 mV to 1000 V AC/DC Current : 10 µA to 1000 A AC/DC TC, RTD : PT-100,J,K,R,S,T,E,B,N Resistance : 1 ohm to 100 G ohm Frequency : 1 Hz to 10 MHz Capacitance : 10 nF to 1 µF Type of Instruments Calibrated Multi Product Calibrator Multi Function Calibrator Digital Multimeter Frequency Counter Signal Generator Decade Resistance Box Meggar Power Supplies Analog Voltmeter/Ammeter Digital Voltmeter/Ammeter AC/DC Clamp meter Temperature Indicator/controller I/P,P/I Convertor Valve Positioner Process Flow Indicator LCR Meter Process Flow Totalizer, etc., High Voltage 1 kV to 30 kV Type of Instruments Calibrated AC/DC High Voltage source Timer 1s to 99999s Type of Instruments Calibrated Digital Timer Analog Timer Stop Watch, etc., Note: Price May vary based on quantity and instruments

68179d65be22ee500d53ff54 Card 2

product image
SSPRT/MTC

Model: MTC-02 Type: R, S Temperature Range: (a) 200 to 1500°C (b) 100 to 1200°C Accuracy: Class 1 (0.6°C or 0.1% of Temperature which ever is greater) Temperature Scale: ITS-90 Sheath Material: K-99 grade ceramic Thermocouple wire dia: 0.5mm Probe dia & Length: 6mm OD & 450mm Length Reference Junction Sheath Dimensions: 250mm Long, 5mm Diameter Cable Length Between sensor and CJS sensor: 700mm Cable Length from CJC sensor: 1.5 meter length Handle Dimension: 20mm OD & 100mm Length Calibration Certified: ISO/IEC 17025 Accredited 5 point

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501/ - 40 Display: 3.5 inch True TFT LCD Display with Touch screen Temperature Range: -40 to 50°C Resolution: 0.01°C Heating & Cooling medium: ETHYLENE GLYCOL HOCH2CH2OH purity 99% (3litres) + Pure distilled water (1.5 litres ) for range from - 40 to 50 °C Stability: ± 0.05°C Uniformity: ± 0.2°C Stabilization Time: 15 minutes Heating time: 30 mins Cooling time: 60 mins (amb. (25°C to - 40°C ) @25°C Multi hole PP top cover: Provided for test Thermometer or sensor holding Power supply: 230V AC 50/60Hz Power Consumption: 1300 VA Calibration chamber size: 90 W x 120 H x 175 D mm Overall Dimension: 530 x 340 x 670 (L x W x H) (+155mm circulation motor) (Approx.) Weight: 52 kg (without liquid)

68179d65be22ee500d53ff54 Card 2

product image
Analytical Instruments

Model: TDSI 642 Display: 3½ digit 0.5” seven segment LED display TDS range: 0–20 ppm / 0–200 ppm / 0–2000 ppm / 0–20 ppt / 0–200 ppt (any one) Conductivity range: 0–20 µS / 0–200 µS / 0–2000 µS / 0–20 mS / 0–200 mS Calibration: Zero and Span provided on front panel Accuracy: ±1% FS + 1 digit Resolution: Minimum 0.01 ppm depending on range Cell constant: 0.1 or 1 as per range Input connection: Terminal Operating temperature: 0–50°C Operating humidity: 20–95% RH non-condensing Power supply: 90–270 V AC 50 Hz Dimensions: 48 × 96 × 65 mm Cut-out dimensions: 44 × 92 mm Weight: 170 grams

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : PCAL 1300 / 1 (Pneumatic) Display : 128 × 64 COG Graphic LCD with White LED Back Light Range (bar) : −0.9 to 1 bar Pressure Media : Air Resolution (bar) : 6 Digit User Selectable Accuracy : ± 0.05% FS Pressure Pump : PVP – 01 Instrument Port (at Pump) : 3/8” BSP Female Test Port (at Pump) : ¼” BSP Female Instrument Port : 3/8” BSP Male Pump Dimension in mm (Approx.) : 230 × 220 × 70 (H × W × D) Instrument Dimension in mm : 100 × 100 × 55 (W × H × D) Instrument Weight : 400 gms (Approx.) Stability Time : 1 to 2 mins Pressure Units (Selectable)* : bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O Pressure Zero : One Touch Zero Provided on Front Key Pressure Peak : Maximum & Minimum with User Reset Option Pressure Overflow : FS × 2 (Max.) Pressure Burst : FS × 3 (Max.) Temperature Measure : RTD – PT100 (2, 3, 4 Wire Selectable) Temperature Range : −199.999 to 850.000 mA Measure : 0–24 mA (Scalable) Display Scale : −99999 to 99999 Counts (for mA Measure Input) Switch Test : Provided Display Hold : One Touch Hold Provided on Front Key Power Supply : 9 V DC ±5% / 600 mAh Rechargeable Battery with Battery Life 20 Hours without Backlight (or) 9 V DC Adapter / 230 V AC Supply Operated PC Interface (Optional) : RS-485 (2 Wire) (Note: Connect to PC using USB to RS-485 Converter Supplied along with PC Software) PC Software (Optional) : Windows Based Semi-Automatic Calibration Software (Optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : PCAL 1300 / 2 bar Range (bar) : −0.9 to 2 bar Pressure Media : Air Pressure Pump : PVP – 01, 02 Display : 128 × 64 COG Graphic LCD with White LED Back Light Instrument Port (at Pump) : 3/8” BSP Female Test Port (at Pump) : ¼” BSP Female Instrument Port : 3/8” BSP Male Pump Dimension in mm (Approx.) : PVP – 01 (230 × 220 × 70 mm (H × W × D)), PVP – 02 (230 × 140 × 65 mm (L × B × H)) Resolution (bar) : 6 Digit User Selectable Instrument Port (Extended) : ¼” BSP Male × 10 mm Long Instrument Dimension : 100 × 100 × 55 (W × H × D) mm Instrument Weight : 400 gms (Approx.) Stability Time : 1 to 2 mins Accuracy : ± 0.05% FS Pressure Units (Selectable)* : bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O Pressure Zero : One Touch Zero Provided on Front Key Pressure Peak : Maximum & Minimum with User Reset Option Pressure Overflow : FS × 2 (Max.) Pressure Burst : FS × 3 (Max.) Temperature Measure : RTD – PT100 (2, 3, 4 Wire Selectable) Temperature Range : −199.999 to 850.000 mA Measure : 0–24 mA (Scalable) Display Scale : −99999 to 99999 Counts (for mA Measure Input) Switch Test : Provided Display Hold : One Touch Hold Provided on Front Key Power Supply : 9 V DC ±5% / 600 mAh Rechargeable Battery with Battery Life 20 Hours without Backlight (or) 9 V DC Adapter / 230 V AC Supply Operated Pump Weight (gms) (Approx.) : PVP – 01 (1.1 kg), PVP – 02 (750 gms) PC Interface (Optional) : RS-485 (2 Wire) (Note: Connect to PC using USB to RS-485 Converter Supplied along with PC Software) PC Software (Optional) : Windows Based Semi-Automatic Calibration Software (Optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / -80 Display: 4.3 inch true TFT display with touch screen Working Range: -80 to -40 °C Resolution: 0.01 °C Stability: ± 0.03 °C Uniformity: ± 0.2 °C Bath Temperature Control: Digital Temperature Controller with FUZZY PID Multi Hole Well: Provided for Different type of Sensors, Sensor with Indicator & Thermometer Calibration Cooling medium: IPA Liquid Capacity: 5 Liters Testing Area: 100mm W x 100mm H x 190mm D Over all Dimension: 705mm L x 505mm W x 825mm H Power Supply: 230V AC ± 10% / 50Hz (Optional 110V44 AC) Weight: 80 kg (approx.)

Still searching for
sub zero temperature probe calibration?