Model: TCAL 1501/ - 40
Display: 3.5 inch True TFT LCD Display with Touch screen
Temperature Range: -40 to 50°C
Resolution: 0.01°C
Heating & Cooling medium: ETHYLENE GLYCOL HOCH2CH2OH purity 99% (3litres) + Pure distilled water (1.5 litres ) for range from - 40 to 50 °C
Stability: ± 0.05°C
Uniformity: ± 0.2°C
Stabilization Time: 15 minutes
Heating time: 30 mins
Cooling time: 60 mins (amb. (25°C to - 40°C ) @25°C
Multi hole PP top cover: Provided for test Thermometer or sensor holding
Power supply: 230V AC 50/60Hz
Power Consumption: 1300 VA
Calibration chamber size: 90 W x 120 H x 175 D mm
Overall Dimension: 530 x 340 x 670 (L x W x H) (+155mm circulation motor) (Approx.)
Weight: 52 kg (without liquid)
Model: Pcal 1300 / 700 bar
Range (bar): 0 to 700 bar
Pressure media: Oil & Water
Pressure pump: CT – 02
Display: 128 × 64 COG Graphic LCD with White LED Backlight
Resolution (bar): 6 digit user selectable
Instrument Port: ½” BSP Male x 10 mm long
Instrument dimension: 100 × 100 × 55 (W × H × D) mm
Instrument Weight: 400 gms (Approx.)
Stability time: 1 to 2 mins
Accuracy: ± 0.05% FS
Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero: One touch zero provided on front key
Pressure Peak: Maximum & minimum with user reset option
Pressure overflow: FS X 2 (Max.)
Pressure burst: FS X 3 (Max.)
Temp.Measure: RTD - PT 100 (2,3,4, wire selectable)
Temp. Range: -199.999 to 850.000
mA Measure: 0-24 mA (scalable)
Display scale: -99999 to 99999 counts (for mA measure input)
Switch test: Provided
Display Hold: One touch hold provided on front key
Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
Pump Weight (Approx.): 14 kg
PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
PC Software (optional): Windows-based semi-automatic calibration software (Optional)
Model : TCAL 1503 / -100
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -100°C to 40°C @20°C to 30°C Ambient
Resolution : 0.01 °C
Block Stability (30 mins) : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.05 °C at full range
Temperature Read out : °C / °F (selectable)
Heating time :
25°C to 40°C : 30 min
-100 to 25°C : 80 min
Cooling Time: 25°C to -100°C : 85 min
40 to 25°C : 12 min
Stabilization time : 15 minutes
Insert Dia. x Height: 30 x 120 mm
Test sensor immersion depth: 115 mm
Standard well holes in mm : Insert No. 1 : 5.1, 6.2, 6.2 & 8.1
Insert No. 2 : 6.2, 6.2 & 10.2
Measure inputs: RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, V, mV, Ohms
Cold junction Accuracy: ± 0.3°C
Communication: RS 485 MODBUS
Switch Test: Provided
Sensor supply output: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption : 500 VA
Overall Dimension in mm : 356 x 210 x 534 (L x B x H)(Approx.)
Instrument Weight :15.9 kg(with well insert)(Approx.)
Model : TCAL 1503 / -40
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -40 to 120°C @23°C Ambient
Resolution : 0.01 °C
Block Stability : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.02°C at full range
Block Axial Uniformity (upto 40mm) : ± 0.18°C at -45°C
± 0.1°C at 0°C
± 0.05°C at 50°C
± 0.11°C at 100°C
± 0.17°C at 120°C
Temperature Read out : °C / °F (selectable)
Loading effect: Better than ± 0.08°C
hysteresis: Better than ± 0.03°C
Cooling time :
30 mins (25 to -45 °C)
15 mins (25 to -30 °C)
65 mins (120 to 25 °C)
Heating time : 25 mins (25 to 120 °C)
75 mins (-45 to 120 °C)
52 mins (-45 to 25 °C)
Stabilization time: 10 minutes
Insert (Dia. x Height): 30 x 160 mm
Test sensor immersion depth: 130 mm
Standard well holes in mm: Insert No. 1 → 5.1, 6.2, 6.2 & 8.1, Insert No. 2 → 6.2, 6.2 & 10.2
Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms
Cold junction Accuracy: ± 0.3°C
UUC Sensor supply input: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (optional 110V AC)
Power Consumption: 500 VA
Switch Test : Provided
Overall Dimension in mm: 390 x 185 x 356 (L x B x H) (Approx.)
Weight: 17.3 kg (with well insert) (Approx.)
Model : TCAL 1503 / -35
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -35 to 120 °C @ 23 °C Ambient
Resolution : 0.01 °C
Block Stability : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.02°C at full range
Block Axial Uniformity (upto 40mm) : ± 0.20°C at -35°C
± 0.05°C at 0°C
± 0.05°C at 50°C
± 0.17°C at 100°C
Loading effect: Better than ± 0.08°C
Hysteresis: Better than ± 0.03°C
Heating time: 25 mins (25 to 120 °C)
75 mins (-35 to 120 °C)
52 mins (-35 to 25 °C)
Cooling time: 25 mins (25 to -35 °C)
15 mins (25 to -30 °C)
65 mins (120 to 25 °C)
Stabilization Time : 10 minutes
Test sensor immersion depth: 130 mm
Standard well holes in mm : Insert No. 1 →5.1, 6.2, 6.2 & 8.1, Insert No. 2 →6.2, 6.2 & 10.2
Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms
Cold junction Accuracy: ± 0.3°C
UUC Sensor supply input: 24V DC ± 10% / 50mA max.
Switch Test : Provided
Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption : 500 VA
Overall Dimension in mm : 390 x 185 x 356 (L x B x H)(Approx.)
Instrument Weight : 17.3 kg (with well insert)(Approx.)
Model: TCAL 1501 / 300
Display: 4.3 inch True TFT LCD Display with Touch screen
Temperature Range : Amb. to 300°C
Resolution: 0.01°C
Stability: ± 0.03°C
Radial uniformity: Better than ± 0.2°C
Measure inputs: RTD-PT 50, 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms
Temperature Readout: C
Stabilization Time: 15 minutes
Heating time: 30 mins (25 to 600°C)
Cooling time: 50 mins (600 to 100°C )
Well Dimension: 30 x 150 mm (dia x height)
Test sensor immersion depth: 140 mm
Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1
PC Interface (optional): RS 232 with automatic calibration software
UUC Sensor supply output: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (optional 110V AC)
Power Consumption: 1200 VA
Switch test: Provided
Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.)
Weight: 8.5 kg (without well insert) (Approx.)
Model: Tcal 1501 / -80
Display: 4.3 inch true TFT display with touch screen
Working Range: -80 to -40 °C
Resolution: 0.01 °C
Stability: ± 0.03 °C
Uniformity: ± 0.2 °C
Bath Temperature Control: Digital Temperature Controller with FUZZY PID
Multi Hole Well: Provided for Different type of Sensors, Sensor with Indicator & Thermometer Calibration
Cooling medium: IPA
Liquid Capacity: 5 Liters
Testing Area: 100mm W x 100mm H x 190mm D
Over all Dimension: 705mm L x 505mm W x 825mm H
Power Supply: 230V AC ± 10% / 50Hz (Optional 110V44 AC)
Weight: 80 kg (approx.)
Model: Pcal 1300 / 1000 bar
Range (bar): 0 to 1000 bar
Pressure media: Oil & Water
Pressure pump: CT – 02
Display: 128 × 64 COG Graphic LCD with White LED Backlight
Resolution (bar): 6 digit user selectable
Instrument Port: ½” BSP Male x 10 mm long
Instrument dimension: 100 × 100 × 55 (W × H × D) mm
Instrument Weight: 400 gms (Approx.)
Stability time: 1 to 2 mins
Accuracy: ± 0.05% FS
PSI: 17400 Psi
Over pressure: 120%
Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero: One touch zero provided on front key
Pressure Peak: Maximum & minimum with user reset option
Pressure overflow: FS X 2 (Max.)
Pressure burst: FS X 3 (Max.)
Temp.Measure: RTD - PT 100 (2,3,4, wire selectable)
Temp. Range: -199.999 to 850.000
mA Measure: 0-24 mA (scalable)
Display scale: -99999 to 99999 counts (for mA measure input)
Switch test: Provided
Display Hold: One touch hold provided on front key
Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
Pump Weight (Approx.): 14 kg
PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
PC Software (optional): Windows-based semi-automatic calibration software (Optional)
Model : PCAL 1300 / 2 bar
Range (bar) : −0.9 to 2 bar
Pressure Media : Air
Pressure Pump : PVP – 01, 02
Display : 128 × 64 COG Graphic LCD with White LED Back Light
Instrument Port (at Pump) : 3/8” BSP Female
Test Port (at Pump) : ¼” BSP Female
Instrument Port : 3/8” BSP Male
Pump Dimension in mm (Approx.) : PVP – 01 (230 × 220 × 70 mm (H × W × D)), PVP – 02 (230 × 140 × 65 mm (L × B × H))
Resolution (bar) : 6 Digit User Selectable
Instrument Port (Extended) : ¼” BSP Male × 10 mm Long
Instrument Dimension : 100 × 100 × 55 (W × H × D) mm
Instrument Weight : 400 gms (Approx.)
Stability Time : 1 to 2 mins
Accuracy : ± 0.05% FS
Pressure Units (Selectable)* : bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero : One Touch Zero Provided on Front Key
Pressure Peak : Maximum & Minimum with User Reset Option
Pressure Overflow : FS × 2 (Max.)
Pressure Burst : FS × 3 (Max.)
Temperature Measure : RTD – PT100 (2, 3, 4 Wire Selectable)
Temperature Range : −199.999 to 850.000
mA Measure : 0–24 mA (Scalable)
Display Scale : −99999 to 99999 Counts (for mA Measure Input)
Switch Test : Provided
Display Hold : One Touch Hold Provided on Front Key
Power Supply : 9 V DC ±5% / 600 mAh Rechargeable Battery with Battery Life 20 Hours without Backlight (or) 9 V DC Adapter / 230 V AC Supply Operated
Pump Weight (gms) (Approx.) : PVP – 01 (1.1 kg), PVP – 02 (750 gms)
PC Interface (Optional) : RS-485 (2 Wire) (Note: Connect to PC using USB to RS-485 Converter Supplied along with PC Software)
PC Software (Optional) : Windows Based Semi-Automatic Calibration Software (Optional)
Model : PCAL 1300 / 1 (Pneumatic)
Display : 128 × 64 COG Graphic LCD with White LED Back Light
Range (bar) : −0.9 to 1 bar
Pressure Media : Air
Resolution (bar) : 6 Digit User Selectable
Accuracy : ± 0.05% FS
Pressure Pump : PVP – 01
Instrument Port (at Pump) : 3/8” BSP Female
Test Port (at Pump) : ¼” BSP Female
Instrument Port : 3/8” BSP Male
Pump Dimension in mm (Approx.) : 230 × 220 × 70 (H × W × D)
Instrument Dimension in mm : 100 × 100 × 55 (W × H × D)
Instrument Weight : 400 gms (Approx.)
Stability Time : 1 to 2 mins
Pressure Units (Selectable)* : bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero : One Touch Zero Provided on Front Key
Pressure Peak : Maximum & Minimum with User Reset Option
Pressure Overflow : FS × 2 (Max.)
Pressure Burst : FS × 3 (Max.)
Temperature Measure : RTD – PT100 (2, 3, 4 Wire Selectable)
Temperature Range : −199.999 to 850.000
mA Measure : 0–24 mA (Scalable)
Display Scale : −99999 to 99999 Counts (for mA Measure Input)
Switch Test : Provided
Display Hold : One Touch Hold Provided on Front Key
Power Supply : 9 V DC ±5% / 600 mAh Rechargeable Battery with Battery Life 20 Hours without Backlight (or) 9 V DC Adapter / 230 V AC Supply Operated
PC Interface (Optional) : RS-485 (2 Wire) (Note: Connect to PC using USB to RS-485 Converter Supplied along with PC Software)
PC Software (Optional) : Windows Based Semi-Automatic Calibration Software (Optional)
Model: Pcal 1300 / ± 350 mbar
Range (bar): ± 350 mbar
Pressure media: Air
Pressure pump: PVP – 01
Display: 128 × 64 COG Graphic LCD with White LED Backlight
Test Port (at pump): ¼” BSP Female
Instrument port (at pump): 3/8” BSP Female
Instrument Port: 3/8” BSP Male
Pump dimension in mm (Approx.): 230 × 220 × 70 mm (H × W × D)
Resolution (bar): 6 digit user selectable
Instrument dimension: 100 × 100 × 55 (W × H × D) mm
Instrument Weight: 400 gms (Approx.)
Stability time: 1 to 2 mins
Accuracy: ± 0.05% FS
Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, cmH₂O, mmH₂O
Pressure Zero: One touch zero provided on front key
Pressure Peak: Maximum & minimum with user reset option
Pressure overflow: FS X 2 (Max.)
Pressure burst: FS X 3 (Max.)
Temp.Measure: RTD - PT 100 (2,3,4, wire selectable)
Temp. Range: -199.999 to 850.000
mA Measure: 0-24 mA (scalable)
Display scale: -99999 to 99999 counts (for mA measure input)
Switch test: Provided
Display Hold: One touch hold provided on front key
Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
Pump Weight (gms) (Approx.): 1.1 kg
PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
PC Software (optional): Windows-based semi-automatic calibration software (optional)