Model :DN 1000
Display : 0.5” 3 ½ Digit 7 segment Red LED
Range : 0 to 19.9 & 199.9 NTU
Resolution : 0.1 NTU
Detector : Photo Diode
Test Tube : 30mm Dia Clear Glass Test tube x 4 nos
Light Source : High Intensity 5mm White LED
Operating Environment : 0 to 50 °C / 20 to 95 % RH non condensing
Power supply : 230V AC / 50 Hz ± 10%
Overall Dimension in mm : 220 x 200 x 110 (L x B x H)
Instrument Weight : 1.7 kg (Approx.)
Model: Pcal 1300 / 700 bar
Range (bar): 0 to 700 bar
Pressure media: Oil & Water
Pressure pump: CT – 02
Display: 128 × 64 COG Graphic LCD with White LED Backlight
Resolution (bar): 6 digit user selectable
Instrument Port: ½” BSP Male x 10 mm long
Instrument dimension: 100 × 100 × 55 (W × H × D) mm
Instrument Weight: 400 gms (Approx.)
Stability time: 1 to 2 mins
Accuracy: ± 0.05% FS
Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O
Pressure Zero: One touch zero provided on front key
Pressure Peak: Maximum & minimum with user reset option
Pressure overflow: FS X 2 (Max.)
Pressure burst: FS X 3 (Max.)
Temp.Measure: RTD - PT 100 (2,3,4, wire selectable)
Temp. Range: -199.999 to 850.000
mA Measure: 0-24 mA (scalable)
Display scale: -99999 to 99999 counts (for mA measure input)
Switch test: Provided
Display Hold: One touch hold provided on front key
Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
Pump Weight (Approx.): 14 kg
PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
PC Software (optional): Windows-based semi-automatic calibration software (Optional)
Model: DCM 200
Display: 0.5” 3 ½ Digit 7 segment Red LED
Range: 0 – 20 μS/ 200 μS/ 2000 μS/ 20 mS / 200 mS ( 5 range selection using front rotary switch )
Resolution: 0.01 / 0.1 / 1 for μS range & 0.01 / 0.1 for mS range
Accuracy: ± 1 % of Range ± 1 digit
Temperature Compensation: 0 to 50°C (Manual) continuously adjustable
Cell Constant: Adjustable with indication on display
Sensor: Platinum Conductivity cell (1.0 cell constant) with Banana male connector
Input Connection: Banana socket
Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing
Power supply: 230V AC / 50 Hz ± 10%
Overall Dimensions in mm: 185 x 235 x 65 ( L x B x H )
Instrument weight: 1.6 kg (Approx.)
Model : TCAL 1503 / -100
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -100°C to 40°C @20°C to 30°C Ambient
Resolution : 0.01 °C
Block Stability (30 mins) : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.05 °C at full range
Temperature Read out : °C / °F (selectable)
Heating time :
25°C to 40°C : 30 min
-100 to 25°C : 80 min
Cooling Time: 25°C to -100°C : 85 min
40 to 25°C : 12 min
Stabilization time : 15 minutes
Insert Dia. x Height: 30 x 120 mm
Test sensor immersion depth: 115 mm
Standard well holes in mm : Insert No. 1 : 5.1, 6.2, 6.2 & 8.1
Insert No. 2 : 6.2, 6.2 & 10.2
Measure inputs: RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, V, mV, Ohms
Cold junction Accuracy: ± 0.3°C
Communication: RS 485 MODBUS
Switch Test: Provided
Sensor supply output: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption : 500 VA
Overall Dimension in mm : 356 x 210 x 534 (L x B x H)(Approx.)
Instrument Weight :15.9 kg(with well insert)(Approx.)
Model: HTD 200
Display: 2.8” True colour TFT display with touch screen
Range:
Temperature: -40 to 85 °C (T), Humidity: 0 to 100% RH (RH)
Resolution: 0.01 °C / 0.01 % RH
Accuracy at 23 °C± 5 °C : ± 0.2 °C / ±0.8 % RH
Psychometric calculated indication: Dew / Frost point ( Dp / Fp )
Wet Bulb Temperature ( Tw )
Vapour partial pressure ( E )
Vapour Saturation pressure ( Ew )
Mixing ratio by weight (dry) ( g / kg )
Enthalpy ( H ) ( KJ / kg )
Specific Humidity (moisture) ( g / kg )
Absolute Humidity (moisture) ( g / m³ )
Volume mixing ratio (dry) ( ppm )
Calculation method: WMO method
Display refresh rate: 1 s (typical)
Calibration : 5 point lookup table for both Temperature & Humidity
Alarm: Audible & Visible user settable individual High & Low alarm set with alarm mode selection for all the 3 parameters
Touch sound: On / Off option available
Logging interval: 1 sec to 24 Hrs programmable
Memory capacity: 4 to 32 GB Internal storage
Data download: Via USB
Battery charging port: USB C type
Integrated battery: 3.7V / 10,000 mAh Inbuilt rechargeable polymer Li-ion battery
Backlight time interval: 0(OFF) to 59 mins : 59 secs (user adjustable)
Brightness adjustment: 10 to 100% (user adjustable)
Application environment range: -10 to 60 °C / 0 to 100% RH (non condensed)
Storage environment range: -10 to 45 °C / 10 to 90% RH
Housing material: ABS with anti-slip grip silicon cover
Protection class: IP40
Overall Dimension in mm: 35 x 80 x 165 mm ( L x B x H)
Instrument Weight: 560 g (Approx.)
Model : TCAL 1503 / -40
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -40 to 120°C @23°C Ambient
Resolution : 0.01 °C
Block Stability : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.02°C at full range
Block Axial Uniformity (upto 40mm) : ± 0.18°C at -45°C
± 0.1°C at 0°C
± 0.05°C at 50°C
± 0.11°C at 100°C
± 0.17°C at 120°C
Temperature Read out : °C / °F (selectable)
Loading effect: Better than ± 0.08°C
hysteresis: Better than ± 0.03°C
Cooling time :
30 mins (25 to -45 °C)
15 mins (25 to -30 °C)
65 mins (120 to 25 °C)
Heating time : 25 mins (25 to 120 °C)
75 mins (-45 to 120 °C)
52 mins (-45 to 25 °C)
Stabilization time: 10 minutes
Insert (Dia. x Height): 30 x 160 mm
Test sensor immersion depth: 130 mm
Standard well holes in mm: Insert No. 1 → 5.1, 6.2, 6.2 & 8.1, Insert No. 2 → 6.2, 6.2 & 10.2
Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms
Cold junction Accuracy: ± 0.3°C
UUC Sensor supply input: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (optional 110V AC)
Power Consumption: 500 VA
Switch Test : Provided
Overall Dimension in mm: 390 x 185 x 356 (L x B x H) (Approx.)
Weight: 17.3 kg (with well insert) (Approx.)
Model: PI – 541A
Display: 6 Digit 7 segment RED LED
Inputs: 0 - 20 mA, 0 to 75 mV, -10 to 10 V DC, 0 – 4000 Ω (H & L Limit Programmable)
RTD - PT 100, PT-1000, Thermocouple - J, K, R, S, T, B, N, E
Cold junction Accuracy: ± 0.3°C
Resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1°C Selectable for Analog
0.01°C for RTD and 0.1°C for TC
Unit selection: °C / °F (for RTD & TC inputs)
Linearization: Programmable custom Linearization provided (1 - 21 points)
Input signal filter: 1 – 100% user configurable
Cold junction compensation: Automatic inbuilt ‘CJC’ is provided
Relay Output* (optional): 2 Relay (5A rated) with 4 Relay Status Selection, Hysteresis, Cyclic Delay
Alarm settings: Front key settable
Alarm indication : Two LED on front panel
Re Transmission* (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC for process variable
PC communication* (optional): RS 485 (2 wire) MODBUS protocol
PC Software* (optional): Monitoring, Data logging, Report & graph
Sensor excitation Supply: 24 V DC ±10% @ 100 mA
Power supply: 90 to 270 V AC / DC / 50/60 Hz
Front panel : IP 65 protection
Operating environment: 0 to 50°C / 5 to 95% RH non condensing
Overall Dimensions: 48(H) X 96(W) X 110(D) mm
Cut out Dimension: 44(H) x 90(W) mm
Enclosure: ABS plastic
Weight: 350 grams (Approx.)
Model : pH 600 - 1
Display : 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display
Input Impedance : >10 Ohms
Range : -2 to 16 pH
Resolution : 0.01 pH
Temperature sensor: RTD - PT 100 (3 wire)
Temp. Compensation: Manual / Automatic (-20.0 to +150.0ºC)
Electrode Input: Combined Electrode with BNC Attachment
Accuracy : ± 0.01 pH ± 1 digit
Set Point - 1 & 2: Two Set Point with 6 Relay Status Selectable
Relay Output : Relay - 1 for Setpoint - 1, Relay - 2 for Setpoint - 2 with 5A Rating
Relay Hysteresis : 0 to 5 pH (user adjustable)(only for High & Low control modes)
Relay Cyclic delay : 0 to 100 seconds (user adjustable)(only for High & Low control modes)
Alarm Output(optional) inbuilt audible buzzer with front key reset
Optional Re. Tx. output Galvanically Isolated : 4 - 20 mA
Optional Comm. output Isolated RS 485
Comm. Protocol MODBUS RTU
Operating Environment : -10 to 50ºC / 10 to 95 % RH Non Condensing
Power Supply : 90 to 270V AC / DC 50Hz
Dimension : 96 x 96 x 85 mm.
Cutout Dimension : 92 x 92 mm
Weight : 500 grams (Approx.)
Model: TDS 602-1
Display: 4 + 4 Digit 0.5” & 0.39” 7-Segment Red LED Display
Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range)
Range (any one): 1–20 ppm, 5–200 ppm, 10–2000 ppm, 1–20 ppt, 5–200 ppt
Accuracy: ±1% of range +1 digit
Resolution: 0.01 ppm to 0.1 ppt (depends on range)
Temperature Sensor: RTD – PT100 (3-wire)
Temperature Coefficient: 0 to 3% / °C (user adjustable)
Temperature Compensation: Manual / Automatic (-20.0 to +150.0 °C)
Electrode Input: Conductivity cell on rear panel
Set Point – 1 & 2: Two set points with 6 relay status selectable
Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating
Relay Hysteresis: 0 to 500 counts (user adjustable) (only for High & Low control modes)
Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes)
Alarm Output (optional): Inbuilt audible buzzer with front-key reset
Optional Re-Tx Output: Galvanically isolated 4–20 mA
Optional Comm. Output: Isolated RS-485
Communication Protocol: MODBUS RTU
Operating Environment: -10 to 50 °C / 10 to 95% RH non-condensing
Power Supply: 90 to 270 V AC / DC, 50 Hz
Enclosure: ABS plastics
Dimension: 96 × 96 × 85 mm
Cutout Dimension: 92 × 92 mm
Weight: 350 grams (Approx.)
Model: CC 603 - 1
Display: 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display
Range (any one): 1 – 20µS, 5 – 200µS, 10 to 2000µS, 1 to 20mS, 5 to 200mS
Resolution: 0.01µS to 0.1mS (depends on range)
Accuracy: ±1% of range ±1 digit
Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range)
Temperature Sensor: RTD – PT 100 (3 wire)
Temperature Co-efficient: 0 to 3% / °C (user adjustable)
Temperature Compensation: Manual / Automatic (-20.0 to +150.0°C)
Electrode Input: Conductivity cell on rear panel
Set Point – 1 & 2: Two set points with 6 relay status selectable
Relay Output:
Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating
Relay Hysteresis: 0 to 500 counts (user adjustable)
(only for High & Low control modes)
Relay Cyclic Delay: 0 to 100 seconds (user adjustable)
(only for High & Low control modes)
Alarm Output (optional): Inbuilt audible buzzer with front key reset
Optional Re-Tx Output: Galvanically isolated 4 – 20 mA
Optional Comm. Output: Isolated RS-485
Comm. Protocol: MODBUS RTU
Operating Environment: -10 to 50°C / 10 to 95% RH non-condensing
Power Supply: 90 to 270V AC / DC, 50Hz
Dimension: 96 × 96 × 85 mm
Cutout Dimension: 92 × 92 mm
Weight: 350 grams (Approx.)
Model: ORT 601-1
Display: 4 + 4 Digit 0.5” & 0.39” 7-Segment Red LED Display
Range: -1999 to 1999 ORP
Accuracy: ±1 ORP ±1 digit
Resolution: 1 ORP
Electrode Input: Platinum electrode with BNC attachment
Set Point – 1 & 2: Two set points with 6 relay status selectable
Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating
Relay Hysteresis: 0 to 5 ORP (user adjustable) (only for High & Low control modes)
Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes)
Input Impedance: >10¹² ohms
Alarm Output (optional): Inbuilt audible buzzer with front-key reset
Optional Re-Tx Output: Galvanically isolated 4–20 mA
Optional Comm. Output: Isolated RS-485
Communication Protocol: MODBUS RTU
Operating Environment: -10 to 50 °C / 10 to 95% RH non-condensing
Power Supply: 90 to 270 V AC / DC, 50 Hz
Dimension: 96 × 96 × 85 mm
Cutout Dimension: 92 × 92 mm