Chennai
08048035791
+917299972093

'testing area 100mm w'

Items tagged with 'testing area 100mm w'

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / -80 Display: 4.3 inch true TFT display with touch screen Working Range: -80 to -40 °C Resolution: 0.01 °C Stability: ± 0.03 °C Uniformity: ± 0.2 °C Bath Temperature Control: Digital Temperature Controller with FUZZY PID Multi Hole Well: Provided for Different type of Sensors, Sensor with Indicator & Thermometer Calibration Cooling medium: IPA Liquid Capacity: 5 Liters Testing Area: 100mm W x 100mm H x 190mm D Over all Dimension: 705mm L x 505mm W x 825mm H Power Supply: 230V AC ± 10% / 50Hz (Optional 110V44 AC) Weight: 80 kg (approx.)

68179d65be22ee500d53ff54 Card 2

product image
SSPRT/MTC

Model: MTC-02 Type: R, S Temperature Range: (a) 200 to 1500°C (b) 100 to 1200°C Accuracy: Class 1 (0.6°C or 0.1% of Temperature which ever is greater) Temperature Scale: ITS-90 Sheath Material: K-99 grade ceramic Thermocouple wire dia: 0.5mm Probe dia & Length: 6mm OD & 450mm Length Reference Junction Sheath Dimensions: 250mm Long, 5mm Diameter Cable Length Between sensor and CJS sensor: 700mm Cable Length from CJC sensor: 1.5 meter length Handle Dimension: 20mm OD & 100mm Length Calibration Certified: ISO/IEC 17025 Accredited 5 point

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / 250 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range: Amb. +5 to 250°C Resolution: 0.01°C Stability: ± 0.03°C Accuracy: Better than ± 0.3°C Stabilization Time: 45 minutes Heating time: 60 mins (Amb. to 250°C) Cooling time: 90 mins (250 to 50°C ) Chamber Dimension: 80 x 140 mm (dia X depth) Testing area: 60 x 120 mm (dia X depth) Temperature medium: Silicon oil (200cs recommended) Measure inputs: RTD-PT 100, PT 1000 / TC-J, K, R, S, T, E, B , N / mA /mV / ohms PC Interface: RS 485 (optional) Power supply: 230V AC or 110V AC 50/60Hz Power Consumption: 1200 VA Switch test: Provided Dimension in mm: 340 x 175 x 425 (L x W x H) (Approx.) Weight (Approx.): 12 kg (without oil)

68179d65be22ee500d53ff54 Card 2

product image
Master Indicators

Specification: Measurement Range: Dew Point (Dp): -8 °C to +20 °C Relative Humidity (RH): 0% to 100%RH Temperature (T): -20 °C to +70 °C Resolution : 0.01 °C / % RH Accuracy: ± 1 °C at 50…-20 °Ctd ± 2 °C at -20…-50 °Ctd ± 3 °C at -50…-80 °Ctd Display: 2.8” True Colour TFT with Touch Screen Sensor Supply Output: 15 V DC Display Refresh Rate: 1 second (typical) Data download: Via USB C-type to PC software (Sansel-Soft-01) Alarm: Audible & Visible, user-settable high & low alarms for all parameters Calibration (1 to 5 points each parameter): Multipoint Calibration for temperature & humidity Touch sound: On / Off option available Integrated battery: 3.7 V / 10,000 mAh Inbuilt rechargeable Li-ion battery Battery charging port: USB C-type Backlight Time Interval: Adjustable from OFF to 59 mins : 59 secs Application Environment Range: -1 °C to +60 °C; 0% to 100% RH (non-condensed) Storage Environment Range: -10 to 45 °C ; 10 to 90% RH Housing Material: ABS with anti-slip grip silicon cover Protection Class: IP40 Dimension ( L x B x H): 35 x 80 x 165 mm Weight: Approximately 560 g

68179d65be22ee500d53ff54 Card 2

product image
Master Indicators

Measurement Range: Dew Point (Dp): -8 °C to +20 °C Relative Humidity (RH): 0% to 100%RH Temperature (T): -20 °C to +70 °C Resolution : 0.01 °C / % RH Accuracy: ± 1 °C at 50…-20 °Ctd ± 2 °C at -20…-50 °Ctd ± 3 °C at -50…-80 °Ctd Display: 2.8” True Colour TFT with Touch Screen Sensor Supply Output: 15 V DC Display Refresh Rate: 1 second (typical) Data download: Via USB C-type to PC software (Sansel-Soft-01) Alarm: Audible & Visible, user-settable high & low alarms for all parameters Calibration (1 to 5 points each parameter): Multipoint Calibration for temperature & humidity Touch sound: On / Off option available Integrated battery: 3.7 V / 10,000 mAh Inbuilt rechargeable Li-ion battery Battery charging port: USB C-type Backlight Time Interval: Adjustable from OFF to 59 mins : 59 secs Application Environment Range: -1 °C to +60 °C; 0% to 100% RH (non-condensed) Storage Environment Range: -10 to 45 °C ; 10 to 90% RH Housing Material: ABS with anti-slip grip silicon cover Protection Class: IP40 Dimension ( L x B x H): 35 x 80 x 165 mm Weight: Approximately 560 g

68179d65be22ee500d53ff54 Card 2

product image
NABL accreditated laboratory

We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABLNABL)national accreditation board for testing and calibration laboratories from Chennai, Tamil Nadu, India. Very Low Pressure ± 25 mbar Type of Instruments Calibrated Manometer Low pressure Transducer/Transmitter Gauges Differential Pressure Indicator/Tranmitter Pressure Data Logger Pressure switch Low pressure Calibrators,etc., Absolute Pressure: 0.60 bar to 2 bar Type of Instruments Calibrated Barometers Aneroid barometer Absolute gauges Absolute pressure sensor/Tranmitter Absolute pressure indicator/ controller Logger and Calibrators etc Vacuum: -0.1 bar to -0.99 bar Type of Instruments Calibrated Vacuum Gauge Vacuum Tranduer/Transmitter Vacuum Indicator/Controller/Switch Vacuum Logger Calibrators etc., Pressure(Hydraulic and Pneumatic) 1 bar to 1000 bar and 0.1 bar to 35 bar Type of Instruments Calibrated Pressure Calibrators Pressure Transducer Pressure Transmitter Digital Pressure Gauges Pressure Controller Pnueumatic pressure gauges Hydraulic Pressure gauges Differential pressure indicators, etc., Mass/Weight 1 mg to 50 kg Type of Instruments Calibrated(Accuracy class: E2,F1,F2,M1,M2,ETC.,) Standard weight box Weights, etc., Weighing Scale and Balance 1mg to 300 Kg Micro balance Analytical balance Digital balance Weighing Scale Volume 1µl to 5l Type of Instruments Calibrated Pipette Burette Flask beaker

68179d65be22ee500d53ff54 Card 2

product image
NABL accreditated laboratory

We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India. Voltage : 1 mV to 1000 V AC/DC Current : 10 µA to 1000 A AC/DC TC, RTD : PT-100,J,K,R,S,T,E,B,N Resistance : 1 ohm to 100 G ohm Frequency : 1 Hz to 10 MHz Capacitance : 10 nF to 1 µF Type of Instruments Calibrated Multi Product Calibrator Multi Function Calibrator Digital Multimeter Frequency Counter Signal Generator Decade Resistance Box Meggar Power Supplies Analog Voltmeter/Ammeter Digital Voltmeter/Ammeter AC/DC Clamp meter Temperature Indicator/controller I/P,P/I Convertor Valve Positioner Process Flow Indicator LCR Meter Process Flow Totalizer, etc., High Voltage 1 kV to 30 kV Type of Instruments Calibrated AC/DC High Voltage source Timer 1s to 99999s Type of Instruments Calibrated Digital Timer Analog Timer Stop Watch, etc., Note: Price May vary based on quantity and instruments

68179d65be22ee500d53ff54 Card 2

product image
NABL accreditated laboratory

We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India. Temperature(Contact) Range from -80 deg C to 1500 deg c Type of Instruments Calibrated: Digital Thermometer Glass Thermometer Dry block Calibrators Thermocouple and RTD probes Thermistors Temperature Recorder Temperature Scanner/Data logger Temperature Indicator with sensor Temperature Gauge Temperature Transmitter Temperature bath,etc., Mapping and Validation for single or multi point Freezer incubator oven furnance Storage rooms clean rooms dryer cold rooms Environmental chambers Humidity Indicator/chamber, etc., Temperature(Non-Contact)Range from 0 deg c to 1500 deg c Type of Instruments Calibrated Non-Contact Pyrometers IR thermometer Black Body Source, ect., Humidity: Range from 5 to 60 deg c & 10 to 95% Type of Instruments Calibrated Humidity sensors/Transmitter Humidity/Temperature logger Analog hygrometer

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: FI 593 Display : 16 Character X 2 Line LCD Display Input (factory settable): 4-20mA / 0-20mA / 0-2.5V / 0-5V / 0 - 10V / 0 - 75mV (any One) Accuracy at 25°C: ± 0.1% of FS Resolution : 1 / 0.1 / 0.01 (any One User Selectable) Display Modes: Flow Rate (FR) & Total Flow (TF) Display Range: 0 - 9999 (4 Digits) for FR , 0 - 99999999(8 Digits) for TF Units: m³ , Liter, Gallons (Selectable) Voltage Drop: 1 V Maximum (Applicable only for current input models) Input Impedance: 18K Ohms (Applicable only for voltage input models) Conversation Modes:Linear, Square Root (User Selectable) Flow Rate Time Base: Seconds, Minutes, Hours (Selectable) Sensor Supply: 24 V DC / 100mA Max. Power Supply: 90 to 270 V AC Operating Environment: 0 to 60°C / 5 to 95 % RH Non Condensing Frequency : 50 / 60 Hz

Still searching for
testing area 100mm w?