Chennai
08048035791
+917299972093

'red black body temperature calibrator bcal'

Items tagged with 'red black body temperature calibrator bcal'

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

“SANSEL” Series BCAL 1502 is a Micro controller Based Precision Temperature Calibrators Generates True Reference Temperature. The Temperature Controller of the Calibrators Uses a Auto Tune PID Control Algorithm. Infra red thermometer & online pyrometer calibration is performed by comparison of the temperature measured by UUC and target temperature indicated by the calibrator or using standard pyrometer. Focus the Unit Under Calibration (UUC) to be Calibrate to the target point given in BCAL 1502. Set the Temperature from the Touch screen display. Both True and set Temperature can be read. When Stabilization Occurs, Simply Read the Temperature and re-Calibrate the UUC. Model: BCAL 1502 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range: 500 to 1500 °C Resolution: 0.1°C Stability: ± 1°C Radial Uniformity: ± 1% of reading Bath Temperature Control: Digital Temperature Controller with Auto Tune PID Algorithm Temperature readout: °C Aperture area: 30mm Emissivity: 0.950 Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 4 KVA Dimension (W*D*H) (Approx.): 580mm W x 450mm D x 390mm H Instrument Weight (Approx): 45 kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

SANSEL Model BCAL 40, Black body Calibrator is used to measure the accuracy and performance of non-contact fever detection systems, like medical thermometer & image scanner. Now it is being used in relation to COVID-19 (corona virus). This Blackbody Source meets the demand for a simple cost effective solution but high accurate device for the calibration of thermal imager and IR thermometers that are used at temperature around that of the human body. Unlike Heat only devices, This model uses a solid state Heat & cool Technology, so that this can be generate both Heat and Cool. This having benefits to maintain the block temperature in different ambient temperature. BCAL 40 using True colour 3.5” Touch screen display, easy to read multi parameter at the same time like Block temperature, Set temperature, Control status, Output % level, range of the equipment, displays both °C & °F and two Touch screen soft keys are used for settings and one more advantage of help menu to guide the operating Instruction of the equipment. Hence no need of hard copy of Instruction manual. Model: BCAL 40 Display: 3.5 inch True TFT LCD Display with Touch screen Temperature Range: Body mode: 20 to 50°C / 68 to 122°F, Surface mode: 0 to 100°C / 32 to 212°F Resolution : 0.01°C Stability: ± 0.03°C Uniformity: ± 0.3°C Stabilization Time: 10 minutes Temperature readout: °C & °F at a time Heating time: 10 mins (Amb. To 50°C ) Power supply: 90 to 260V AC/DC / 50/60Hz Power Consumption: Less than 100 VA Aperture area: 25mm Emissivity: 0.950 Overall Dimension: 210 x 210 x 140 (L x B x H)(Approx.) Instrument Weight: 3.7 kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : BCAL 1202 Display : 4.3 inch True TFT DISPLAY with touch screen Temperature Range : 500 to 1200°C Resolution : 0.1 °C Stability : ± 0.2 °C Radial Uniformity : Better than ± 1% of reading Temperature Read out : °C Heating time : 60 min (Amb. to 1200 °C) Cooling time : 120 min (1200 to 100 °C) Stabilization time : 30 minutes Aperture area : 25 mm Emissivity : 0.950 Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption : 2200 VA Overall Dimension in mm : 350 x 352 x 210 (L x B x H)(Approx.) Instrument Weight : 12 kg(without carrying case)(Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL BCAL : 502 Display : 4+4 digit 7 segment LED Display Temperature Range : 50 to 500 °C Resolution : 0.1°C Stability : ± 0.2 °C Uniformity in aperture area: ± 0.5°C@50°C, ± 1.7@250°C , ± 2.5@500°C Heating Time (to Max) : 40 Minutes Cooling Time (to Max) : 40 Minutes to 100°C Aperture area : 25 mm Emissivity : 0.950 Power Supply : 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption : 500 VA Instrument Weight : 4.5 kg

68179d65be22ee500d53ff54 Card 2

product image
NABL accreditated laboratory

We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India. Temperature(Contact) Range from -80 deg C to 1500 deg c Type of Instruments Calibrated: Digital Thermometer Glass Thermometer Dry block Calibrators Thermocouple and RTD probes Thermistors Temperature Recorder Temperature Scanner/Data logger Temperature Indicator with sensor Temperature Gauge Temperature Transmitter Temperature bath,etc., Mapping and Validation for single or multi point Freezer incubator oven furnance Storage rooms clean rooms dryer cold rooms Environmental chambers Humidity Indicator/chamber, etc., Temperature(Non-Contact)Range from 0 deg c to 1500 deg c Type of Instruments Calibrated Non-Contact Pyrometers IR thermometer Black Body Source, ect., Humidity: Range from 5 to 60 deg c & 10 to 95% Type of Instruments Calibrated Humidity sensors/Transmitter Humidity/Temperature logger Analog hygrometer

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/500 Display: 2.8" True TFT with Touch screen Temperature Range: Amb. + 5 to 500 °C Radial uniformity: (Better than) ±0.05°C Resolution: 0.01 °C Stability: ±0.08 °C Temperature readout: °C Heating time: Amb to 500 --> 25 min Cooling time: 500 to 50--> 1 hr 20 min Stabilization time: 15 mins Well Dimension(dia. x height): 20 x 100 mm Well immersion depth: 90 mm Standard well holes in mm: 6.2 x 2nos Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 350 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.75 Kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/300 Display: 2.8" True TFT with Touch screen Temperature Range: Amb. + 5 to 300 °C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.04 °C Temperature readout: °C Heating time: Amb to 300 -->23 min Cooling time: 300 to 50-->30 min Stabilization time: 15 mins Well Dimension(dia. x height): 20 x 100 mm Well immersion depth: 90 mm Standard well holes in mm: 6.2 x 2nos Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 250 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 2.75 Kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model TCAL: 1404/-15 Display: 2.8' True TFT with Touch screen Temperature Range: -15 to 120 °C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.03 °C Temperature readout: °C Heating time: Amb to 120-->25 min, -15 to Amb -->5 min Cooling time: Amb to -15 -->20 min, 120 to 50 -->8 min Stabilization time: 10 mins Well Dimension(dia. x height): 20 x 90 mm Well immersion depth: 90 mm (throw hole) Standard well holes in mm: 6.2 x 2nos Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz Power consumption: 100 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.5 Kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/-5 Display: 2.8' True TFT with Touch screen Temperature Range: -5 to 100°C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.03 °C Temperature readout: °C Heating time: Amb to 100-->15min, -5 to Amb -->3 min Cooling time: Amb to -5 -->15min, 100 to 50-->4 min Stabilization time: 10 mins Well Dimension(dia. x height): 20 x 90 mm Well immersion depth: 90 mm (throw hole) Standard well holes in mm: 6.2 x 2nos Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz Power consumption: 100 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.5 Kg

Still searching for
red black body temperature calibrator bcal?