68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: CC 603 - 1 Display: 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display Range (any one): 1 – 20µS, 5 – 200µS, 10 to 2000µS, 1 to 20mS, 5 to 200mS Resolution: 0.01µS to 0.1mS (depends on range) Accuracy: ±1% of range ±1 digit Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range) Temperature Sensor: RTD – PT 100 (3 wire) Temperature Co-efficient: 0 to 3% / °C (user adjustable) Temperature Compensation: Manual / Automatic (-20.0 to +150.0°C) Electrode Input: Conductivity cell on rear panel Set Point – 1 & 2: Two set points with 6 relay status selectable Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating Relay Hysteresis: 0 to 500 counts (user adjustable) (only for High & Low control modes) Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes) Alarm Output (optional): Inbuilt audible buzzer with front key reset Optional Re-Tx Output: Galvanically isolated 4 – 20 mA Optional Comm. Output: Isolated RS-485 Comm. Protocol: MODBUS RTU Operating Environment: -10 to 50°C / 10 to 95% RH non-condensing Power Supply: 90 to 270V AC / DC, 50Hz Dimension: 96 × 96 × 85 mm Cutout Dimension: 92 × 92 mm Weight: 350 grams (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model : DL 96/97 Display : Multi colour TFT display with Touch screen No. of Channel : 8 or 16or 24 or 32 channel Password Access :Provided for all configuration settings Analog & Temp. Inputs (selectable for Universal Model) : RTD- PT100 TC-J,K,R,S, mA, mV, Volt Input Range (optional against order) : O)RTDPI10099.9 to 300.0 C (-199.9 to 300.0 optional) (2) 0-20 mA:-999 to 4000(-1999 to 9999 optional) (3) 4-20 mA999 to 4000 (4) 01Vdc:-999 to 4000 (5) 05 Vdc-999 to 4000 (6) TC J:0to 700 °C (7) TC-K0 to 1200°C (8) TC-S:0to 1600° C (9) TC-R:0to 1600°C Alarm Output : 1 or2Common Relay(5ARated) Aarm Set point : High & Low Set point tor each channel(user selectable) Log Interval : 1sec to 24 hour (selectable) PC software : Provided With logging, Alarm Setup, Record, Graph PC Communication : RS 232 or RS 485 or USB or Ethernet (TOP/IP) Baud Rate : 19600 bps Printer port : Parallel printer port provided USB Connecton : USB2.0Tor PENdrive data transter Termperature drift : ≤0.01% FSC(typical 50 ppm) Elecromagnetic Compatibility : TEC6T0OOE4KVI5KFZIEC6TOOO-4-5, 4KV Response time : ≤1.5 seconds if digital filter parameter is set as 0 or 1 Automatic pilot time : Approx12s or 2s confiqurable Enclosure : Aluminium case Mounting : Panel Mounting Operating Environment : 0 to 50C 20 to 95.% RH non condensing Weight : 1kg

68179d65be22ee500d53ff54 Card 2

product image
Analytical Instruments

Model: TDS 602-1 Display: 4 + 4 Digit 0.5” & 0.39” 7-Segment Red LED Display Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range) Range (any one): 1–20 ppm, 5–200 ppm, 10–2000 ppm, 1–20 ppt, 5–200 ppt Accuracy: ±1% of range +1 digit Resolution: 0.01 ppm to 0.1 ppt (depends on range) Temperature Sensor: RTD – PT100 (3-wire) Temperature Coefficient: 0 to 3% / °C (user adjustable) Temperature Compensation: Manual / Automatic (-20.0 to +150.0 °C) Electrode Input: Conductivity cell on rear panel Set Point – 1 & 2: Two set points with 6 relay status selectable Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating Relay Hysteresis: 0 to 500 counts (user adjustable) (only for High & Low control modes) Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes) Alarm Output (optional): Inbuilt audible buzzer with front-key reset Optional Re-Tx Output: Galvanically isolated 4–20 mA Optional Comm. Output: Isolated RS-485 Communication Protocol: MODBUS RTU Operating Environment: -10 to 50 °C / 10 to 95% RH non-condensing Power Supply: 90 to 270 V AC / DC, 50 Hz Enclosure: ABS plastics Dimension: 96 × 96 × 85 mm Cutout Dimension: 92 × 92 mm Weight: 350 grams (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Master Indicators

Specification: Measurement Range: Dew Point (Dp): -8 °C to +20 °C Relative Humidity (RH): 0% to 100%RH Temperature (T): -20 °C to +70 °C Resolution : 0.01 °C / % RH Accuracy: ± 1 °C at 50…-20 °Ctd ± 2 °C at -20…-50 °Ctd ± 3 °C at -50…-80 °Ctd Display: 2.8” True Colour TFT with Touch Screen Sensor Supply Output: 15 V DC Display Refresh Rate: 1 second (typical) Data download: Via USB C-type to PC software (Sansel-Soft-01) Alarm: Audible & Visible, user-settable high & low alarms for all parameters Calibration (1 to 5 points each parameter): Multipoint Calibration for temperature & humidity Touch sound: On / Off option available Integrated battery: 3.7 V / 10,000 mAh Inbuilt rechargeable Li-ion battery Battery charging port: USB C-type Backlight Time Interval: Adjustable from OFF to 59 mins : 59 secs Application Environment Range: -1 °C to +60 °C; 0% to 100% RH (non-condensed) Storage Environment Range: -10 to 45 °C ; 10 to 90% RH Housing Material: ABS with anti-slip grip silicon cover Protection Class: IP40 Dimension ( L x B x H): 35 x 80 x 165 mm Weight: Approximately 560 g

68179d65be22ee500d53ff54 Card 2

product image
Master Indicators

Measurement Range: Dew Point (Dp): -8 °C to +20 °C Relative Humidity (RH): 0% to 100%RH Temperature (T): -20 °C to +70 °C Resolution : 0.01 °C / % RH Accuracy: ± 1 °C at 50…-20 °Ctd ± 2 °C at -20…-50 °Ctd ± 3 °C at -50…-80 °Ctd Display: 2.8” True Colour TFT with Touch Screen Sensor Supply Output: 15 V DC Display Refresh Rate: 1 second (typical) Data download: Via USB C-type to PC software (Sansel-Soft-01) Alarm: Audible & Visible, user-settable high & low alarms for all parameters Calibration (1 to 5 points each parameter): Multipoint Calibration for temperature & humidity Touch sound: On / Off option available Integrated battery: 3.7 V / 10,000 mAh Inbuilt rechargeable Li-ion battery Battery charging port: USB C-type Backlight Time Interval: Adjustable from OFF to 59 mins : 59 secs Application Environment Range: -1 °C to +60 °C; 0% to 100% RH (non-condensed) Storage Environment Range: -10 to 45 °C ; 10 to 90% RH Housing Material: ABS with anti-slip grip silicon cover Protection Class: IP40 Dimension ( L x B x H): 35 x 80 x 165 mm Weight: Approximately 560 g

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: PIJ – 541 B1 Display: 2” or 4” or 8” 6 Digit 7 segment RED LED* Accuracy: ± 0.1 % of FS Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable) Temperature inputs: RTD - PT 100, PT 1000, Thermocouple - J, K, R, S, T, B, N, E Analog display range: -199999 to 199999 (H & L Limit programmable) Temperature range (H & L Limit programmable): RTD - PT 100 (-199.99 to 850.00°C / -327.5 to 1562.0 °F) RTD - PT 1000 (-50.0 to 400.0°C / -58.0 to 752.0 °F) TC - J (- 200 to 1200°C / -328 to 2192°F) TC - K (- 200 to 1372°C / -327 to 2501°F) TC - R (- 40 to 1768°C / -40 to 3214°F) TC - S (- 40 to 1768°C / -40 to 3214°F) TC - T (- 200 to 400°C / -328 to 752°F) TC - B (300 to 1820°C / 572 to 3308°F) TC - N (-200 to 1300°C / -327 to 2372°F) TC - E ( -200 to 1000°C / -327 to 1832°F) Unit selection: °C / °F ( for RTD & TC inputs) Analog input display resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1 (Selectable) Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable) Filter constant: 1 – 100% (Adjustable) Display hold option: Peak, hold & average (any one selectable) Hold delay: 0 - 999 sec (selectable) Relay Output (option al): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol PC interface software: Monitoring, Data logging, Report & Graph (Optional) Sensor Supply (external): 24 V DC ±10% @ 100 mA Power supply: 230 V AC / 50 Hz Overall dimension: 611 x 171 x 85 (L x H x D) mm (Approx.) Housing : MS Powder coating Mounting: Wall or sealing with 360 º rotatable clamp Operating environment: 0 - 50°C / 5 to 95% RH Non condensing Weight (Approx.): 5.5 (or) 8.5 kg

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: PIJ – 542 A1 Display: 2” or 4” or 8” 4 Digit 7 segment RED LED* Accuracy: ± 0.1 % of FS Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable) Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E Analog display range: -1999 to 9999 (H & L Limit programmable) Temperature range (H & L Limit programmable): RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F) TC - J (- 200 to 1200°C / -328 to 2192°F) TC - K (- 200 to 1372°C / -327 to 2501°F) TC - R (- 40 to 1768°C / -40 to 3214°F) TC - S (- 40 to 1768°C / -40 to 3214°F) TC - T (- 200 to 400°C / -328 to 752°F) TC - B (300 to 1820°C / 572 to 3308°F) TC - N (-200 to 1300°C / -327 to 2372°F) TC - E ( -200 to 999.9°C / -327 to 1832°F) Unit selection: °C / °F ( for RTD & TC inputs) Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable) Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable) Filter constant: 1 – 100% (Adjustable) Display hold option: Peak, hold & average (any one selectable) Hold delay: 0 - 999 sec (selectable) Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay Temperature drift: ≤ 0.1% FS/°C (typical 50 ppm) Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol PC interface software: Optional Sensor Supply (external): 24 V DC ±10% @ 100 mA Power supply: 230 V AC / 50 Hz Overall dimension: 428 x 171 x 85 (L x H x D) mm (Approx.) Housing : MS Powder coating Mounting: Wall or sealing with 360 º rotatable clamp Operating environment: 0 - 50°C / 5 to 95% RH Non condensing Weight (Approx.): 4.5 kg

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: FI 594 Display : 16 Character X 2 Line LCD Display Input: Pulse Accuracy at 25°C: ± 0.1% of FS Display Modes: Flow Rate (FR) , Total Flow (TF) & Batch Total (BT) Display Range: 0 - 99999(5 Digits) for FR , 0 - 99999999(8 Digits) for TF FR Resolution: 1 / 0.1 / 0.01 (any One Selectable) TF Resolution: 1 / 0.1 / 0.01 / 0.001 (any One Selectable) Units: m³ , Liter, Gallons (Selectable) Flow Rate Time Base: Seconds, Minutes, Hours (Selectable) Password Protection: Provided for User & Supervisor separately Relay Output (optional): 2 Relay Output (5A rated)with Individual Assignment settings for FR, TF & BT) Retransmission Output (optional): Opto isolated 4 - 20mA or 0 - 10V DC (any one factory Presettable) Communication: RS 485 (2 wire) / MODBUS RTU / RS 232 (any one factory Presettable) PC Software: Monitoring, Data logging, Report & Graph Sensor Supply: 5 or 12 V DC / 100mA Max. Operating Environment: 0 to 50 Deg C / 20 to 95 % RH Non Condensing Power Supply: 90 to 270 V AC, 50/60Hz

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model : HTI 197 Display : 2 line , 4 digit , 0.5’’ 7 segment LED Parameter : Temperature & Humidity Range : 0 to 60°C / 0 to 100%RH Resolution : 0.01°C / 0.1%RH Set point: Low & High for both Parameter Accuracy : ± 0.5 °C / ± 3%RH Relay Output ( optional) : 2 relay with 5A rating Sensor : PT-100 & Humidity sensor with 2 meter cable Operating Environment: 0 to 50°C / 20 to 95%RH Non condensing Supply : 90 to 270V AC / 50Hz Dimension : 100 mm W x 250 mm H x 60 mm D Mounting : Wall mountable with key hole provision Buzzer: Inbuilt Weight : 540gms