Calibrators

The Precision Portable Thermometer (PTM-201) is a state-of-the-art handheld measurement device designed for professionals who demand exceptional accuracy, versatility, and reliability. By supporting a wide range of input types—including RTD, Thermocouple, mA, Voltage, Resistance, and mV—this instrument is engineered to adapt to a variety of field and laboratory applications. The PTM-201’s intuitive 2.8” True Colour TFT touchscreen ensures a user-friendly experience, while comprehensive data logging features and a large 16 GB memory enable extensive record-keeping for analysis and compliance. With robust construction, an integrated rechargeable battery, and advanced calibration and alarm capabilities, the PTM-201 is the ideal partner for achieving precise and traceable measurements in demanding environments. Temperature Inputs: RTD, TC Wide Temperature Measurement Ranges: -200 to + 1800 °C Temperature Resolution: 0.01/0.001* °C (*As per selected Input type) Analog Inputs: Resistance, Current, Voltage Wide Analog Measurement Ranges: 0 to 4000 Ohms, 0 to 2omA DC, 0 to 75 mV DC, 0 to 30V DC Analog Measurement Resolution: 0.01 Ohms, 0.001 mA/mV/V Display: 2.8” True Colour TFT touchscreen Operating Conditions: -10 to 60 °C; 0 to 100% RH (non-condensing) Storage Conditions: -10 to 45 °C; 10 to 90% RH Data Recording: Huge Logging Memory upto 16 GB Data Logging Interval: User-selectable from 1 second to 24 hours Data Download: Via USB Type-C to PC software (Sansel-Soft-01) Calibration: Multipoint calibration feature available Alarms: Audible and visible; user-settable high and low thresholds Battery: Integrated 3.7V / 10,000 mAh rechargeable Li-ion Charging Port: USB Type-C Adjustable Settings: Backlight timing, brightness, touch sound Housing: ABS with anti-slip grip silicon cover Protection Class: IP40 Dimensions: 35 x 80 x 165 mm (L x W x H) Weight: Approximately 560 g

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501 / 300 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range : Amb. to 300°C Resolution: 0.01°C Stability: ± 0.03°C Radial uniformity: Better than ± 0.2°C Measure inputs: RTD-PT 50, 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms Temperature Readout: C Stabilization Time: 15 minutes Heating time: 30 mins (25 to 600°C) Cooling time: 50 mins (600 to 100°C ) Well Dimension: 30 x 150 mm (dia x height) Test sensor immersion depth: 140 mm Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1 PC Interface (optional): RS 232 with automatic calibration software UUC Sensor supply output: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (optional 110V AC) Power Consumption: 1200 VA Switch test: Provided Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.) Weight: 8.5 kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501 / 600 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range : Amb. +5 to 600°C Resolution: 0.01°C Stability: ± 0.05°C Radial uniformity: Better than ± 0.5°C Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms Temperature Readout: C Stabilization Time: 15 minutes Heating time: 30 mins (25 to 600°C) Cooling time: 50 mins (600 to 100°C ) Well Dimension: 30 x 150 mm (dia x height) Test sensor immersion depth: 140 mm Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1 PC Interface (optional): RS 232 with automatic calibration software UUC Sensor supply output: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (optional 110V AC) Power Consumption: 1200 VA Switch test: Provided Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.) Weight: 8.5 kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / 250 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range: Amb. +5 to 250°C Resolution: 0.01°C Stability: ± 0.03°C Accuracy: Better than ± 0.3°C Stabilization Time: 45 minutes Heating time: 60 mins (Amb. to 250°C) Cooling time: 90 mins (250 to 50°C ) Chamber Dimension: 80 x 140 mm (dia X depth) Testing area: 60 x 120 mm (dia X depth) Temperature medium: Silicon oil (200cs recommended) Measure inputs: RTD-PT 100, PT 1000 / TC-J, K, R, S, T, E, B , N / mA /mV / ohms PC Interface: RS 485 (optional) Power supply: 230V AC or 110V AC 50/60Hz Power Consumption: 1200 VA Switch test: Provided Dimension in mm: 340 x 175 x 425 (L x W x H) (Approx.) Weight (Approx.): 12 kg (without oil)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : TCAL 1503 / -100 Display : 4.3” True colour TFT display with touch screen Temperature Range : -100°C to 40°C @20°C to 30°C Ambient Resolution : 0.01 °C Block Stability (30 mins) : Better than ± 0.03°C at full range Block Radial Uniformity : ± 0.05 °C at full range Temperature Read out : °C / °F (selectable) Heating time : 25°C to 40°C : 30 min -100 to 25°C : 80 min Cooling Time: 25°C to -100°C : 85 min 40 to 25°C : 12 min Stabilization time : 15 minutes Insert Dia. x Height: 30 x 120 mm Test sensor immersion depth: 115 mm Standard well holes in mm : Insert No. 1 : 5.1, 6.2, 6.2 & 8.1 Insert No. 2 : 6.2, 6.2 & 10.2 Measure inputs: RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, V, mV, Ohms Cold junction Accuracy: ± 0.3°C Communication: RS 485 MODBUS Switch Test: Provided Sensor supply output: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption : 500 VA Overall Dimension in mm : 356 x 210 x 534 (L x B x H)(Approx.) Instrument Weight :15.9 kg(with well insert)(Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : TCAL 1503 / -40 Display : 4.3” True colour TFT display with touch screen Temperature Range : -40 to 120°C @23°C Ambient Resolution : 0.01 °C Block Stability : Better than ± 0.03°C at full range Block Radial Uniformity : ± 0.02°C at full range Block Axial Uniformity (upto 40mm) : ± 0.18°C at -45°C ± 0.1°C at 0°C ± 0.05°C at 50°C ± 0.11°C at 100°C ± 0.17°C at 120°C Temperature Read out : °C / °F (selectable) Loading effect: Better than ± 0.08°C hysteresis: Better than ± 0.03°C Cooling time : 30 mins (25 to -45 °C) 15 mins (25 to -30 °C) 65 mins (120 to 25 °C) Heating time : 25 mins (25 to 120 °C) 75 mins (-45 to 120 °C) 52 mins (-45 to 25 °C) Stabilization time: 10 minutes Insert (Dia. x Height): 30 x 160 mm Test sensor immersion depth: 130 mm Standard well holes in mm: Insert No. 1 → 5.1, 6.2, 6.2 & 8.1, Insert No. 2 → 6.2, 6.2 & 10.2 Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms Cold junction Accuracy: ± 0.3°C UUC Sensor supply input: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (optional 110V AC) Power Consumption: 500 VA Switch Test : Provided Overall Dimension in mm: 390 x 185 x 356 (L x B x H) (Approx.) Weight: 17.3 kg (with well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : TCAL 1503 / -35 Display : 4.3” True colour TFT display with touch screen Temperature Range : -35 to 120 °C @ 23 °C Ambient Resolution : 0.01 °C Block Stability : Better than ± 0.03°C at full range Block Radial Uniformity : ± 0.02°C at full range Block Axial Uniformity (upto 40mm) : ± 0.20°C at -35°C ± 0.05°C at 0°C ± 0.05°C at 50°C ± 0.17°C at 100°C Loading effect: Better than ± 0.08°C Hysteresis: Better than ± 0.03°C Heating time: 25 mins (25 to 120 °C) 75 mins (-35 to 120 °C) 52 mins (-35 to 25 °C) Cooling time: 25 mins (25 to -35 °C) 15 mins (25 to -30 °C) 65 mins (120 to 25 °C) Stabilization Time : 10 minutes Test sensor immersion depth: 130 mm Standard well holes in mm : Insert No. 1 →5.1, 6.2, 6.2 & 8.1, Insert No. 2 →6.2, 6.2 & 10.2 Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms Cold junction Accuracy: ± 0.3°C UUC Sensor supply input: 24V DC ± 10% / 50mA max. Switch Test : Provided Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption : 500 VA Overall Dimension in mm : 390 x 185 x 356 (L x B x H)(Approx.) Instrument Weight : 17.3 kg (with well insert)(Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : Pcal 1300 / 20 bar Display : 128 x 64 COG Graphic LCD with White LED Back light Range (bar) : -1 to 20 bar Accuracy : ± 0.05%FS Resolution (bar) : 6 digit user selectable Instrument Port : 1/4' BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (WxHxD) mm Instrument Weight : 400gms (Appox.) Stability time : 1 to 2 mins Pressure units* (selectable) :bar, mbar, Mpa, kpa, kg/cm2, inHg,cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: PIJ – 541 B1 Display: 2” or 4” or 8” 6 Digit 7 segment RED LED* Accuracy: ± 0.1 % of FS Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable) Temperature inputs: RTD - PT 100, PT 1000, Thermocouple - J, K, R, S, T, B, N, E Analog display range: -199999 to 199999 (H & L Limit programmable) Temperature range (H & L Limit programmable): RTD - PT 100 (-199.99 to 850.00°C / -327.5 to 1562.0 °F) RTD - PT 1000 (-50.0 to 400.0°C / -58.0 to 752.0 °F) TC - J (- 200 to 1200°C / -328 to 2192°F) TC - K (- 200 to 1372°C / -327 to 2501°F) TC - R (- 40 to 1768°C / -40 to 3214°F) TC - S (- 40 to 1768°C / -40 to 3214°F) TC - T (- 200 to 400°C / -328 to 752°F) TC - B (300 to 1820°C / 572 to 3308°F) TC - N (-200 to 1300°C / -327 to 2372°F) TC - E ( -200 to 1000°C / -327 to 1832°F) Unit selection: °C / °F ( for RTD & TC inputs) Analog input display resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1 (Selectable) Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable) Filter constant: 1 – 100% (Adjustable) Display hold option: Peak, hold & average (any one selectable) Hold delay: 0 - 999 sec (selectable) Relay Output (option al): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol PC interface software: Monitoring, Data logging, Report & Graph (Optional) Sensor Supply (external): 24 V DC ±10% @ 100 mA Power supply: 230 V AC / 50 Hz Overall dimension: 611 x 171 x 85 (L x H x D) mm (Approx.) Housing : MS Powder coating Mounting: Wall or sealing with 360 º rotatable clamp Operating environment: 0 - 50°C / 5 to 95% RH Non condensing Weight (Approx.): 5.5 (or) 8.5 kg