Chennai
08048035791
+917299972093

'liquid capacity 5 liters'

Items tagged with 'liquid capacity 5 liters'

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / -80 Display: 4.3 inch true TFT display with touch screen Working Range: -80 to -40 °C Resolution: 0.01 °C Stability: ± 0.03 °C Uniformity: ± 0.2 °C Bath Temperature Control: Digital Temperature Controller with FUZZY PID Multi Hole Well: Provided for Different type of Sensors, Sensor with Indicator & Thermometer Calibration Cooling medium: IPA Liquid Capacity: 5 Liters Testing Area: 100mm W x 100mm H x 190mm D Over all Dimension: 705mm L x 505mm W x 825mm H Power Supply: 230V AC ± 10% / 50Hz (Optional 110V44 AC) Weight: 80 kg (approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : HCAL 1104U Display: 7” True colour TFT LCD Display with Touch screen Control Range : 5 to 60°C / 3 to 95 % RH* Dew point Temperature range (psychometric calculated) : -30°C to 45°C Psychometric calculated indication : Dew / Frost point ( Dp / Fp ) Wet Bulb Temperature ( Tw ) Vapour partial pressure ( E ) Vapour Saturation pressure ( Ew ) Mixing ratio by weight (dry) ( g / kg ) Enthalpy ( H ) ( KJ / kg ) Specific Humidity (moisture) ( g / kg ) Absolute Humidity (moisture) ( g / m³ ) Volume mixing ratio (dry) ( ppm ) Calculation method : WMO method Resolution : 0.01 °C / 0.01% RH Display stability : Better than ± 0.03 °C / ± 0.15% RH Chamber stability @25°C ** Temperature: ± 0.1°C, Humidity: ± 0.3 % RH Chamber Uniformity @25°C** Temperature: ± 0.2°C, Humidity: ± 0.5 % RH Test sensor insert port: Inter changeable Acrylic door is provided on front side of the chamber with pg21 gland (cable or sensor size range from 13 to 18mm) x 3nos External Humidifier Water tank capacity: 6 litres (approx.)(NOTE : 3 liter filling is enough for our application) Humidifier Liquid: Distilled water Humidifying Time:2 %RH / sec (50 to 90 % RH) Dehumidifying Time: 6 %RH / sec (50 to 10 % RH) Test chamber area: 230mm DIA x 170mm D (Approx) Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 1000 VA Construction: Inner chamber SS 310 / outer MS powder coating Overall Dimension: 436mm L x 676mm W x 368mm H (Approx.) Weight: 46 kg (without Accessories) + 6 kg (standard accessories) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / 250 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range: Amb. +5 to 250°C Resolution: 0.01°C Stability: ± 0.03°C Accuracy: Better than ± 0.3°C Stabilization Time: 45 minutes Heating time: 60 mins (Amb. to 250°C) Cooling time: 90 mins (250 to 50°C ) Chamber Dimension: 80 x 140 mm (dia X depth) Testing area: 60 x 120 mm (dia X depth) Temperature medium: Silicon oil (200cs recommended) Measure inputs: RTD-PT 100, PT 1000 / TC-J, K, R, S, T, E, B , N / mA /mV / ohms PC Interface: RS 485 (optional) Power supply: 230V AC or 110V AC 50/60Hz Power Consumption: 1200 VA Switch test: Provided Dimension in mm: 340 x 175 x 425 (L x W x H) (Approx.) Weight (Approx.): 12 kg (without oil)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501/ - 40 Display: 3.5 inch True TFT LCD Display with Touch screen Temperature Range: -40 to 50°C Resolution: 0.01°C Heating & Cooling medium: ETHYLENE GLYCOL HOCH2CH2OH purity 99% (3litres) + Pure distilled water (1.5 litres ) for range from - 40 to 50 °C Stability: ± 0.05°C Uniformity: ± 0.2°C Stabilization Time: 15 minutes Heating time: 30 mins Cooling time: 60 mins (amb. (25°C to - 40°C ) @25°C Multi hole PP top cover: Provided for test Thermometer or sensor holding Power supply: 230V AC 50/60Hz Power Consumption: 1300 VA Calibration chamber size: 90 W x 120 H x 175 D mm Overall Dimension: 530 x 340 x 670 (L x W x H) (+155mm circulation motor) (Approx.) Weight: 52 kg (without liquid)

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: PIJ – 541 B1 Display: 2” or 4” or 8” 6 Digit 7 segment RED LED* Accuracy: ± 0.1 % of FS Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable) Temperature inputs: RTD - PT 100, PT 1000, Thermocouple - J, K, R, S, T, B, N, E Analog display range: -199999 to 199999 (H & L Limit programmable) Temperature range (H & L Limit programmable): RTD - PT 100 (-199.99 to 850.00°C / -327.5 to 1562.0 °F) RTD - PT 1000 (-50.0 to 400.0°C / -58.0 to 752.0 °F) TC - J (- 200 to 1200°C / -328 to 2192°F) TC - K (- 200 to 1372°C / -327 to 2501°F) TC - R (- 40 to 1768°C / -40 to 3214°F) TC - S (- 40 to 1768°C / -40 to 3214°F) TC - T (- 200 to 400°C / -328 to 752°F) TC - B (300 to 1820°C / 572 to 3308°F) TC - N (-200 to 1300°C / -327 to 2372°F) TC - E ( -200 to 1000°C / -327 to 1832°F) Unit selection: °C / °F ( for RTD & TC inputs) Analog input display resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1 (Selectable) Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable) Filter constant: 1 – 100% (Adjustable) Display hold option: Peak, hold & average (any one selectable) Hold delay: 0 - 999 sec (selectable) Relay Output (option al): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol PC interface software: Monitoring, Data logging, Report & Graph (Optional) Sensor Supply (external): 24 V DC ±10% @ 100 mA Power supply: 230 V AC / 50 Hz Overall dimension: 611 x 171 x 85 (L x H x D) mm (Approx.) Housing : MS Powder coating Mounting: Wall or sealing with 360 º rotatable clamp Operating environment: 0 - 50°C / 5 to 95% RH Non condensing Weight (Approx.): 5.5 (or) 8.5 kg

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: PIJ – 542 A1 Display: 2” or 4” or 8” 4 Digit 7 segment RED LED* Accuracy: ± 0.1 % of FS Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable) Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E Analog display range: -1999 to 9999 (H & L Limit programmable) Temperature range (H & L Limit programmable): RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F) TC - J (- 200 to 1200°C / -328 to 2192°F) TC - K (- 200 to 1372°C / -327 to 2501°F) TC - R (- 40 to 1768°C / -40 to 3214°F) TC - S (- 40 to 1768°C / -40 to 3214°F) TC - T (- 200 to 400°C / -328 to 752°F) TC - B (300 to 1820°C / 572 to 3308°F) TC - N (-200 to 1300°C / -327 to 2372°F) TC - E ( -200 to 999.9°C / -327 to 1832°F) Unit selection: °C / °F ( for RTD & TC inputs) Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable) Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable) Filter constant: 1 – 100% (Adjustable) Display hold option: Peak, hold & average (any one selectable) Hold delay: 0 - 999 sec (selectable) Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay Temperature drift: ≤ 0.1% FS/°C (typical 50 ppm) Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol PC interface software: Optional Sensor Supply (external): 24 V DC ±10% @ 100 mA Power supply: 230 V AC / 50 Hz Overall dimension: 428 x 171 x 85 (L x H x D) mm (Approx.) Housing : MS Powder coating Mounting: Wall or sealing with 360 º rotatable clamp Operating environment: 0 - 50°C / 5 to 95% RH Non condensing Weight (Approx.): 4.5 kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/500 Display: 2.8" True TFT with Touch screen Temperature Range: Amb. + 5 to 500 °C Radial uniformity: (Better than) ±0.05°C Resolution: 0.01 °C Stability: ±0.08 °C Temperature readout: °C Heating time: Amb to 500 --> 25 min Cooling time: 500 to 50--> 1 hr 20 min Stabilization time: 15 mins Well Dimension(dia. x height): 20 x 100 mm Well immersion depth: 90 mm Standard well holes in mm: 6.2 x 2nos Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 350 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.75 Kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model TCAL: 1404/-15 Display: 2.8' True TFT with Touch screen Temperature Range: -15 to 120 °C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.03 °C Temperature readout: °C Heating time: Amb to 120-->25 min, -15 to Amb -->5 min Cooling time: Amb to -15 -->20 min, 120 to 50 -->8 min Stabilization time: 10 mins Well Dimension(dia. x height): 20 x 90 mm Well immersion depth: 90 mm (throw hole) Standard well holes in mm: 6.2 x 2nos Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz Power consumption: 100 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.5 Kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/-5 Display: 2.8' True TFT with Touch screen Temperature Range: -5 to 100°C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.03 °C Temperature readout: °C Heating time: Amb to 100-->15min, -5 to Amb -->3 min Cooling time: Amb to -5 -->15min, 100 to 50-->4 min Stabilization time: 10 mins Well Dimension(dia. x height): 20 x 90 mm Well immersion depth: 90 mm (throw hole) Standard well holes in mm: 6.2 x 2nos Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz Power consumption: 100 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.5 Kg

Still searching for
liquid capacity 5 liters?