Model: TDS 100
Display: 0.5” 3 ½ Digit 7 segment Red LED
Range: 0 – 20 ppm/ 200 ppm/ 2000 ppm/ 20ppt / 200ppt ( 5 range selection using front rotary switch )
Resolution: 0.01 / 0.1 / 1 for ppm range & 0.01 / 0.1 for ppt range
Accuracy: ± 1 % of Range ± 1 digit
Temperature Compensation: 0 to 50°C (Manual) continuously adjustable
Cell Constant: Adjustable with indication on display
Sensor: Platinum Conductivity cell (1.0 cell constant) with Banana male connector
Input Connection: Banana socket
Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing
Power supply: 230V AC / 50 Hz ± 10%
Overall Dimensions in mm: 185 x 235 x 65 ( L x B x H )
Instrument weight: 1.6 kg (Approx.)
Model: HTD 200
Display: 2.8” True colour TFT display with touch screen
Range:
Temperature: -40 to 85 °C (T), Humidity: 0 to 100% RH (RH)
Resolution: 0.01 °C / 0.01 % RH
Accuracy at 23 °C± 5 °C : ± 0.2 °C / ±0.8 % RH
Psychometric calculated indication: Dew / Frost point ( Dp / Fp )
Wet Bulb Temperature ( Tw )
Vapour partial pressure ( E )
Vapour Saturation pressure ( Ew )
Mixing ratio by weight (dry) ( g / kg )
Enthalpy ( H ) ( KJ / kg )
Specific Humidity (moisture) ( g / kg )
Absolute Humidity (moisture) ( g / m³ )
Volume mixing ratio (dry) ( ppm )
Calculation method: WMO method
Display refresh rate: 1 s (typical)
Calibration : 5 point lookup table for both Temperature & Humidity
Alarm: Audible & Visible user settable individual High & Low alarm set with alarm mode selection for all the 3 parameters
Touch sound: On / Off option available
Logging interval: 1 sec to 24 Hrs programmable
Memory capacity: 4 to 32 GB Internal storage
Data download: Via USB
Battery charging port: USB C type
Integrated battery: 3.7V / 10,000 mAh Inbuilt rechargeable polymer Li-ion battery
Backlight time interval: 0(OFF) to 59 mins : 59 secs (user adjustable)
Brightness adjustment: 10 to 100% (user adjustable)
Application environment range: -10 to 60 °C / 0 to 100% RH (non condensed)
Storage environment range: -10 to 45 °C / 10 to 90% RH
Housing material: ABS with anti-slip grip silicon cover
Protection class: IP40
Overall Dimension in mm: 35 x 80 x 165 mm ( L x B x H)
Instrument Weight: 560 g (Approx.)
Model: ORP 300
Display: 0.5” 3 ½ Digit 7 segment Red LED
Range: -1999 to +1999 mV
Resolution: 1 mV
Accuracy: ± 1 mV ± 1 digit
Input Impedance: > 10¹² Ohms
Input connection: BNC socket
Electrode: ORP Electrode with BNC attachment
Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing
Power supply: 230V AC / 50 Hz ± 10%
Overall Dimensions in mm: 185 x 235 x 65 (L x B x H)
Instrument weight: 1.6 kg (Approx.)
Model: pH 302
Display: 16 Character x 2 line LCD with Backlight
Range: 0 to 14 pH / -1999 to +1999 mV /0 – 150°C
Resolution: 0.01 pH / 1 mV / 0.1°C
Accuracy: ± 0.01 pH ± 1 digit / ± 1 mV ± 1 digit /± 0.5°C ± 1 digit
Input Impedance: > 10¹² Ohms
Temperature Compensation: 0 to 150°C Manual / Automatic
Electrode: Combined pH Electrode with BNC attachment
Temperature sensor: Provided with 3 pin female socket
pH / ORP Input connection: BNC socket
Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing
Temperature connection: 3 pin male socket
Power supply: 230V AC / 50 Hz ± 10%
Overall Dimensions in mm: 190 x 185 x 75 ( L x B x H )
Instrument weight: 1.7 kg (Approx.)
Model : pH 641
Display : 0.5” 3 ½ Digit 7 segment Red LED
Range : 0 to 14 pH / -1999 to 1999 ORP
Input Impedance : > 10¹² Ohms
Accuracy : ± 0.01 pH ± 1 digit / ± 1 ORP ± 1 digit
Resolution :0.01 pH
Electrode: Combined Electrode with BNC attachment
Input connection : BNC socket
Operating Environment : 0 to 50 °C / 20 to 95 % RH non condensing
Power supply : 230V AC / 50 Hz ± 10%
Overall Dimension in mm : 48 x 96 x 65 (H x B x L)
Cut out Dimension in mm : 44 x 92 (H x B)
Instrument Weight : 170 g
Model :DN 1000
Display : 0.5” 3 ½ Digit 7 segment Red LED
Range : 0 to 19.9 & 199.9 NTU
Resolution : 0.1 NTU
Detector : Photo Diode
Test Tube : 30mm Dia Clear Glass Test tube x 4 nos
Light Source : High Intensity 5mm White LED
Operating Environment : 0 to 50 °C / 20 to 95 % RH non condensing
Power supply : 230V AC / 50 Hz ± 10%
Overall Dimension in mm : 220 x 200 x 110 (L x B x H)
Instrument Weight : 1.7 kg (Approx.)
Model: DCM 200
Display: 0.5” 3 ½ Digit 7 segment Red LED
Range: 0 – 20 μS/ 200 μS/ 2000 μS/ 20 mS / 200 mS ( 5 range selection using front rotary switch )
Resolution: 0.01 / 0.1 / 1 for μS range & 0.01 / 0.1 for mS range
Accuracy: ± 1 % of Range ± 1 digit
Temperature Compensation: 0 to 50°C (Manual) continuously adjustable
Cell Constant: Adjustable with indication on display
Sensor: Platinum Conductivity cell (1.0 cell constant) with Banana male connector
Input Connection: Banana socket
Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing
Power supply: 230V AC / 50 Hz ± 10%
Overall Dimensions in mm: 185 x 235 x 65 ( L x B x H )
Instrument weight: 1.6 kg (Approx.)
The Precision Portable Thermometer (PTM-201) is a state-of-the-art handheld measurement device designed for professionals who demand exceptional accuracy, versatility, and reliability. By supporting a wide range of input types—including RTD, Thermocouple, mA, Voltage, Resistance, and mV—this instrument is engineered to adapt to a variety of field and laboratory applications. The PTM-201’s intuitive 2.8” True Colour TFT touchscreen ensures a user-friendly experience, while comprehensive data logging features and a large 16 GB memory enable extensive record-keeping for analysis and compliance. With robust construction, an integrated rechargeable battery, and advanced calibration and alarm capabilities, the PTM-201 is the ideal partner for achieving precise and traceable measurements in demanding environments.
Temperature Inputs: RTD, TC
Wide Temperature Measurement Ranges: -200 to + 1800 °C
Temperature Resolution: 0.01/0.001* °C (*As per selected Input type)
Analog Inputs: Resistance, Current, Voltage
Wide Analog Measurement Ranges: 0 to 4000 Ohms, 0 to 2omA DC, 0 to 75 mV DC, 0 to 30V DC
Analog Measurement Resolution: 0.01 Ohms, 0.001 mA/mV/V
Display: 2.8” True Colour TFT touchscreen
Operating Conditions: -10 to 60 °C; 0 to 100% RH (non-condensing)
Storage Conditions: -10 to 45 °C; 10 to 90% RH
Data Recording: Huge Logging Memory upto 16 GB
Data Logging Interval: User-selectable from 1 second to 24 hours
Data Download: Via USB Type-C to PC software (Sansel-Soft-01)
Calibration: Multipoint calibration feature available
Alarms: Audible and visible; user-settable high and low thresholds
Battery: Integrated 3.7V / 10,000 mAh rechargeable Li-ion
Charging Port: USB Type-C
Adjustable Settings: Backlight timing, brightness, touch sound
Housing: ABS with anti-slip grip silicon cover
Protection Class: IP40
Dimensions: 35 x 80 x 165 mm (L x W x H)
Weight: Approximately 560 g