68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : Pcal 1300 / 20 bar Display : 128 x 64 COG Graphic LCD with White LED Back light Range (bar) : -1 to 20 bar Accuracy : ± 0.05%FS Resolution (bar) : 6 digit user selectable Instrument Port : 1/4' BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (WxHxD) mm Instrument Weight : 400gms (Appox.) Stability time : 1 to 2 mins Pressure units* (selectable) :bar, mbar, Mpa, kpa, kg/cm2, inHg,cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/30 bar Range (bar) :- 0.9 to 30 bar Pressure media : Air Pressure pump : HP-03 Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2 x ¼” BSP Female Pump dimension in mm (Approx.): 230 x 65 x 130 (L x H x W) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (W x H x D) mm Instrument Weight : 400gms (Approx.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units* (selectable) : bar, mbar, Mpa, kpa, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum & minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Switch test: Provided Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light (or) 9V DC adapter / 230V AC supply operated Pump Weight (Approx.) : 1250 grams Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/350 bar Range (bar) : 0 to 350 bar Pressure media : Oil & Water Pressure pump : HP-02A Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2x 1/2' BSP Female Pump dimension in mm (Appox.) : 310 x 80 x 165 (LxHxw) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 55 (W x H x D) mm Instrument Weight : 400gms (Appox.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units (selectable) : bar, mbar, Mpa, kpa, kg/cm2,inHg,cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Pressure overflow : FS X 2 (Max.) Pressure burst : FS X3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/1000 bar Range (bar) : 0- 1000 bar Pressure media : oil & Water Pressure pump : HP-01 Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2 x 1/2' BSP Female Pump dimension in mm (Approx.) : 340 x240 x320(L xH xW) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (W x H x D) mm Instrument Weight : 400gms (Approx.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light (or) 9V DC adapter /230V AC supply operated Pump Weight (Approx.) : 7500 grams Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/2 bar Range (bar) : -0.9 to 2 bar Pressure media : Air Pressure pump : HP-04 ,HP-03 Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2 x1/4 ' BSP Female Pump dimension in mm (Appox.) : 170 x 45 (Height x Dia) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (W x H x D) mm Instrument Weight : 400gms (Appox.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units (selectable) : bar, mbar, Mpa, kpa, kg/cm2, inHg, cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : PCAL 1300/1 bar Range (bar) : -0.9 to 1 bar Pressure media : Air Pressure pump : HP-04 Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2 x1/4 ' BSP Female Pump dimension in mm (Approx.) : 170 x 45 (Height x Dia) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (W x H x D) mm Instrument Weight : 400gms (Approx.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units (selectable) : bar, mbar, Mpa, kpa, kg/cm2, inHg, cmHg, mmHg, mH₂o, ftH₂o, inH₂o, cmH₂o, mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours without back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/±350mbar Range (bar) : ±350 mbar Pressure media : Air Pressure pump : HP-04 Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2 x 1/4' BSP Female Pump dimension in mm (Approx.) : 170 x 45 (Height x Dia) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (W x H x D) mm Instrument Weight : 400gms (Approx.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units* (selectable) :bar, mbar, Mpa, kpa, kg/cm2,inHg,cmHg,mmHg,mH₂o, ftH₂o, inH₂o, cmH₂o, mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/700 bar Range (bar) : 0 - 700 bar Pressure media : oil & Water Pressure pump : HP-01 Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2 x 1/2' BSP Female Pump dimension in mm (Approx.) : 340 x 240 x 320 (LxHxW) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (W x H x D) mm Instrument Weight : 400gms (Approx.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units* (selectable) : bar, mbar, Mpa, kpa, kg/cm2, inHg, cmHg, mmHg, mH₂o, ftH₂o, inH₂o, cmH₂o, mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum & minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light (or) 9V DC adapter /230V AC supply operated Pump Weight (Approx.) : 700 grams Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: PI – 541A Display: 6 Digit 7 segment RED LED Inputs: 0 - 20 mA, 0 to 75 mV, -10 to 10 V DC, 0 – 4000 Ω (H & L Limit Programmable) RTD - PT 100, PT-1000, Thermocouple - J, K, R, S, T, B, N, E Cold junction Accuracy: ± 0.3°C Resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1°C Selectable for Analog 0.01°C for RTD and 0.1°C for TC Unit selection: °C / °F (for RTD & TC inputs) Linearization: Programmable custom Linearization provided (1 - 21 points) Input signal filter: 1 – 100% user configurable Cold junction compensation: Automatic inbuilt ‘CJC’ is provided Relay Output* (optional): 2 Relay (5A rated) with 4 Relay Status Selection, Hysteresis, Cyclic Delay Alarm settings: Front key settable Alarm indication : Two LED on front panel Re Transmission* (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC for process variable PC communication* (optional): RS 485 (2 wire) MODBUS protocol PC Software* (optional): Monitoring, Data logging, Report & graph Sensor excitation Supply: 24 V DC ±10% @ 100 mA Power supply: 90 to 270 V AC / DC / 50/60 Hz Front panel : IP 65 protection Operating environment: 0 to 50°C / 5 to 95% RH non condensing Overall Dimensions: 48(H) X 96(W) X 110(D) mm Cut out Dimension: 44(H) x 90(W) mm Enclosure: ABS plastic Weight: 350 grams (Approx.)

Still searching for