Chennai
08048035791
+917299972093

'display 4 3 inch true tft display'

Items tagged with 'display 4 3 inch true tft display'

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/300 Display: 2.8" True TFT with Touch screen Temperature Range: Amb. + 5 to 300 °C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.04 °C Temperature readout: °C Heating time: Amb to 300 -->23 min Cooling time: 300 to 50-->30 min Stabilization time: 15 mins Well Dimension(dia. x height): 20 x 100 mm Well immersion depth: 90 mm Standard well holes in mm: 6.2 x 2nos Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 250 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 2.75 Kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501 / 300 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range : Amb. to 300°C Resolution: 0.01°C Stability: ± 0.03°C Radial uniformity: Better than ± 0.2°C Measure inputs: RTD-PT 50, 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms Temperature Readout: C Stabilization Time: 15 minutes Heating time: 30 mins (25 to 600°C) Cooling time: 50 mins (600 to 100°C ) Well Dimension: 30 x 150 mm (dia x height) Test sensor immersion depth: 140 mm Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1 PC Interface (optional): RS 232 with automatic calibration software UUC Sensor supply output: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (optional 110V AC) Power Consumption: 1200 VA Switch test: Provided Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.) Weight: 8.5 kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

SANSEL Model BCAL 40, Black body Calibrator is used to measure the accuracy and performance of non-contact fever detection systems, like medical thermometer & image scanner. Now it is being used in relation to COVID-19 (corona virus). This Blackbody Source meets the demand for a simple cost effective solution but high accurate device for the calibration of thermal imager and IR thermometers that are used at temperature around that of the human body. Unlike Heat only devices, This model uses a solid state Heat & cool Technology, so that this can be generate both Heat and Cool. This having benefits to maintain the block temperature in different ambient temperature. BCAL 40 using True colour 3.5” Touch screen display, easy to read multi parameter at the same time like Block temperature, Set temperature, Control status, Output % level, range of the equipment, displays both °C & °F and two Touch screen soft keys are used for settings and one more advantage of help menu to guide the operating Instruction of the equipment. Hence no need of hard copy of Instruction manual. Model: BCAL 40 Display: 3.5 inch True TFT LCD Display with Touch screen Temperature Range: Body mode: 20 to 50°C / 68 to 122°F, Surface mode: 0 to 100°C / 32 to 212°F Resolution : 0.01°C Stability: ± 0.03°C Uniformity: ± 0.3°C Stabilization Time: 10 minutes Temperature readout: °C & °F at a time Heating time: 10 mins (Amb. To 50°C ) Power supply: 90 to 260V AC/DC / 50/60Hz Power Consumption: Less than 100 VA Aperture area: 25mm Emissivity: 0.950 Overall Dimension: 210 x 210 x 140 (L x B x H)(Approx.) Instrument Weight: 3.7 kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : TCAL 1503 / -40 Display : 4.3” True colour TFT display with touch screen Temperature Range : -40 to 120°C @23°C Ambient Resolution : 0.01 °C Block Stability : Better than ± 0.03°C at full range Block Radial Uniformity : ± 0.02°C at full range Block Axial Uniformity (upto 40mm) : ± 0.18°C at -45°C ± 0.1°C at 0°C ± 0.05°C at 50°C ± 0.11°C at 100°C ± 0.17°C at 120°C Temperature Read out : °C / °F (selectable) Loading effect: Better than ± 0.08°C hysteresis: Better than ± 0.03°C Cooling time : 30 mins (25 to -45 °C) 15 mins (25 to -30 °C) 65 mins (120 to 25 °C) Heating time : 25 mins (25 to 120 °C) 75 mins (-45 to 120 °C) 52 mins (-45 to 25 °C) Stabilization time: 10 minutes Insert (Dia. x Height): 30 x 160 mm Test sensor immersion depth: 130 mm Standard well holes in mm: Insert No. 1 → 5.1, 6.2, 6.2 & 8.1, Insert No. 2 → 6.2, 6.2 & 10.2 Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms Cold junction Accuracy: ± 0.3°C UUC Sensor supply input: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (optional 110V AC) Power Consumption: 500 VA Switch Test : Provided Overall Dimension in mm: 390 x 185 x 356 (L x B x H) (Approx.) Weight: 17.3 kg (with well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501/ - 40 Display: 3.5 inch True TFT LCD Display with Touch screen Temperature Range: -40 to 50°C Resolution: 0.01°C Heating & Cooling medium: ETHYLENE GLYCOL HOCH2CH2OH purity 99% (3litres) + Pure distilled water (1.5 litres ) for range from - 40 to 50 °C Stability: ± 0.05°C Uniformity: ± 0.2°C Stabilization Time: 15 minutes Heating time: 30 mins Cooling time: 60 mins (amb. (25°C to - 40°C ) @25°C Multi hole PP top cover: Provided for test Thermometer or sensor holding Power supply: 230V AC 50/60Hz Power Consumption: 1300 VA Calibration chamber size: 90 W x 120 H x 175 D mm Overall Dimension: 530 x 340 x 670 (L x W x H) (+155mm circulation motor) (Approx.) Weight: 52 kg (without liquid)

68179d65be22ee500d53ff54 Card 2

product image
Master Indicators

Measurement Range: 0-1 m/s & 197 fpm, 0-2 m/s & 394 fpm, 0-5 m/s & 984 fpm, 0-10 m/s & 1967 fpm, 0-20 m/s & 3937 fpm (any once factory Presettable) Resolution: 0.01 m/s & 1 fpm Accuracy: ± 5% of Full Scale Display: 2.8” True Colour TFT with Touch Screen Application Environment Range: -10 to 60 °C ; 0 to 100% RH (non condensed) Storage Environment Range: -10 to 45 °C ; 10 to 90% RH Display Refresh Rate: 1 second (typical) Data Logging Interval: 1 sec to 24 Hours (user selectable) Data download: Via USB type-C to PC software (Sansel-Soft-01) Alarm: Audible & Visible, user-settable high & low alarms Calibration: 2 point Calibration feature available Touch sound: On / Off option available Battery charging port: USB C-type Backlight Time Interval: Adjustable from OFF to 59 mins : 59 secs Brightness adjustment: 10% to 100% (user adjustable) Integrated battery: 3.7 V / 10,000 mAh rechargeable Li-ion battery Housing Material: ABS with anti-slip grip silicon cover Protection Class: IP40 Dimension ( L x B x H): 35 x 80 x 165 mm Instrument Weight: 560 g (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Master Indicators

Measurement Range: Temperature (T): -20 to +100 °C Relative Saturation (RS): 0 to 100% RS Water Activity (aw): 0 to 1 aw Resolution : 0.01 °C / % RS & 1 aw Accuracy: aw (0...0.9 aw): ±0.02 aw at 23 °C aw (0...1.0 aw): Typically ±0.03 aw at 23 °C Temperature: ±0.3 °C Display: 2.8” True Colour TFT with Touch Screen Display Refresh Rate: 1 second (typical) Data Logging Interval: 1 sec to 24 Hours (user selectable) Data download: Via USB type-C to PC software (Sansel-Soft-01) Alarm: Audible & Visible, user-settable high & low alarms for all parameters Calibration: 2 point calibration for both temperature and humidity Touch sound: On / Off option available Integrated battery: 3.7 V / 10,000 mAh rechargeable polymer Li-ion battery Battery charging port: USB C-type Backlight Time Interval: Adjustable from 0(OFF) to 59 minutes and 59 seconds Brightness adjustment: 10% to 100% (user adjustable) Application Environment Range: -Temperature: -10°C to 60°C; -Humidity: 0% to 100% RH (non-condensed) Storage Environment Range: -Temperature: -10 to 45 °C ; -Humidity: 10 to 90% RH Housing Material: ABS with anti-slip grip silicon cover Protection Class: IP40 Dimension ( L x B x H): 35 x 80 x 165 mm Instrument Weight: 560 g (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/500 Display: 2.8" True TFT with Touch screen Temperature Range: Amb. + 5 to 500 °C Radial uniformity: (Better than) ±0.05°C Resolution: 0.01 °C Stability: ±0.08 °C Temperature readout: °C Heating time: Amb to 500 --> 25 min Cooling time: 500 to 50--> 1 hr 20 min Stabilization time: 15 mins Well Dimension(dia. x height): 20 x 100 mm Well immersion depth: 90 mm Standard well holes in mm: 6.2 x 2nos Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 350 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.75 Kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model TCAL: 1404/-15 Display: 2.8' True TFT with Touch screen Temperature Range: -15 to 120 °C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.03 °C Temperature readout: °C Heating time: Amb to 120-->25 min, -15 to Amb -->5 min Cooling time: Amb to -15 -->20 min, 120 to 50 -->8 min Stabilization time: 10 mins Well Dimension(dia. x height): 20 x 90 mm Well immersion depth: 90 mm (throw hole) Standard well holes in mm: 6.2 x 2nos Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz Power consumption: 100 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.5 Kg

Still searching for
display 4 3 inch true tft display?