Chennai
08048035791
+917299972093

'conductivity and temperature control system'

Items tagged with 'conductivity and temperature control system'

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: CC 603 - 1 Display: 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display Range (any one): 1 – 20µS, 5 – 200µS, 10 to 2000µS, 1 to 20mS, 5 to 200mS Resolution: 0.01µS to 0.1mS (depends on range) Accuracy: ±1% of range ±1 digit Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range) Temperature Sensor: RTD – PT 100 (3 wire) Temperature Co-efficient: 0 to 3% / °C (user adjustable) Temperature Compensation: Manual / Automatic (-20.0 to +150.0°C) Electrode Input: Conductivity cell on rear panel Set Point – 1 & 2: Two set points with 6 relay status selectable Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating Relay Hysteresis: 0 to 500 counts (user adjustable) (only for High & Low control modes) Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes) Alarm Output (optional): Inbuilt audible buzzer with front key reset Optional Re-Tx Output: Galvanically isolated 4 – 20 mA Optional Comm. Output: Isolated RS-485 Comm. Protocol: MODBUS RTU Operating Environment: -10 to 50°C / 10 to 95% RH non-condensing Power Supply: 90 to 270V AC / DC, 50Hz Dimension: 96 × 96 × 85 mm Cutout Dimension: 92 × 92 mm Weight: 350 grams (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

“SANSEL” Series BCAL 1502 is a Micro controller Based Precision Temperature Calibrators Generates True Reference Temperature. The Temperature Controller of the Calibrators Uses a Auto Tune PID Control Algorithm. Infra red thermometer & online pyrometer calibration is performed by comparison of the temperature measured by UUC and target temperature indicated by the calibrator or using standard pyrometer. Focus the Unit Under Calibration (UUC) to be Calibrate to the target point given in BCAL 1502. Set the Temperature from the Touch screen display. Both True and set Temperature can be read. When Stabilization Occurs, Simply Read the Temperature and re-Calibrate the UUC. Model: BCAL 1502 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range: 500 to 1500 °C Resolution: 0.1°C Stability: ± 1°C Radial Uniformity: ± 1% of reading Bath Temperature Control: Digital Temperature Controller with Auto Tune PID Algorithm Temperature readout: °C Aperture area: 30mm Emissivity: 0.950 Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 4 KVA Dimension (W*D*H) (Approx.): 580mm W x 450mm D x 390mm H Instrument Weight (Approx): 45 kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

SANSEL Model BCAL 40, Black body Calibrator is used to measure the accuracy and performance of non-contact fever detection systems, like medical thermometer & image scanner. Now it is being used in relation to COVID-19 (corona virus). This Blackbody Source meets the demand for a simple cost effective solution but high accurate device for the calibration of thermal imager and IR thermometers that are used at temperature around that of the human body. Unlike Heat only devices, This model uses a solid state Heat & cool Technology, so that this can be generate both Heat and Cool. This having benefits to maintain the block temperature in different ambient temperature. BCAL 40 using True colour 3.5” Touch screen display, easy to read multi parameter at the same time like Block temperature, Set temperature, Control status, Output % level, range of the equipment, displays both °C & °F and two Touch screen soft keys are used for settings and one more advantage of help menu to guide the operating Instruction of the equipment. Hence no need of hard copy of Instruction manual. Model: BCAL 40 Display: 3.5 inch True TFT LCD Display with Touch screen Temperature Range: Body mode: 20 to 50°C / 68 to 122°F, Surface mode: 0 to 100°C / 32 to 212°F Resolution : 0.01°C Stability: ± 0.03°C Uniformity: ± 0.3°C Stabilization Time: 10 minutes Temperature readout: °C & °F at a time Heating time: 10 mins (Amb. To 50°C ) Power supply: 90 to 260V AC/DC / 50/60Hz Power Consumption: Less than 100 VA Aperture area: 25mm Emissivity: 0.950 Overall Dimension: 210 x 210 x 140 (L x B x H)(Approx.) Instrument Weight: 3.7 kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : HCAL 1104U Display: 7” True colour TFT LCD Display with Touch screen Control Range : 5 to 60°C / 3 to 95 % RH* Dew point Temperature range (psychometric calculated) : -30°C to 45°C Psychometric calculated indication : Dew / Frost point ( Dp / Fp ) Wet Bulb Temperature ( Tw ) Vapour partial pressure ( E ) Vapour Saturation pressure ( Ew ) Mixing ratio by weight (dry) ( g / kg ) Enthalpy ( H ) ( KJ / kg ) Specific Humidity (moisture) ( g / kg ) Absolute Humidity (moisture) ( g / m³ ) Volume mixing ratio (dry) ( ppm ) Calculation method : WMO method Resolution : 0.01 °C / 0.01% RH Display stability : Better than ± 0.03 °C / ± 0.15% RH Chamber stability @25°C ** Temperature: ± 0.1°C, Humidity: ± 0.3 % RH Chamber Uniformity @25°C** Temperature: ± 0.2°C, Humidity: ± 0.5 % RH Test sensor insert port: Inter changeable Acrylic door is provided on front side of the chamber with pg21 gland (cable or sensor size range from 13 to 18mm) x 3nos External Humidifier Water tank capacity: 6 litres (approx.)(NOTE : 3 liter filling is enough for our application) Humidifier Liquid: Distilled water Humidifying Time:2 %RH / sec (50 to 90 % RH) Dehumidifying Time: 6 %RH / sec (50 to 10 % RH) Test chamber area: 230mm DIA x 170mm D (Approx) Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 1000 VA Construction: Inner chamber SS 310 / outer MS powder coating Overall Dimension: 436mm L x 676mm W x 368mm H (Approx.) Weight: 46 kg (without Accessories) + 6 kg (standard accessories) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Analytical Instruments

Model: TDS 602-1 Display: 4 + 4 Digit 0.5” & 0.39” 7-Segment Red LED Display Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range) Range (any one): 1–20 ppm, 5–200 ppm, 10–2000 ppm, 1–20 ppt, 5–200 ppt Accuracy: ±1% of range +1 digit Resolution: 0.01 ppm to 0.1 ppt (depends on range) Temperature Sensor: RTD – PT100 (3-wire) Temperature Coefficient: 0 to 3% / °C (user adjustable) Temperature Compensation: Manual / Automatic (-20.0 to +150.0 °C) Electrode Input: Conductivity cell on rear panel Set Point – 1 & 2: Two set points with 6 relay status selectable Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating Relay Hysteresis: 0 to 500 counts (user adjustable) (only for High & Low control modes) Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes) Alarm Output (optional): Inbuilt audible buzzer with front-key reset Optional Re-Tx Output: Galvanically isolated 4–20 mA Optional Comm. Output: Isolated RS-485 Communication Protocol: MODBUS RTU Operating Environment: -10 to 50 °C / 10 to 95% RH non-condensing Power Supply: 90 to 270 V AC / DC, 50 Hz Enclosure: ABS plastics Dimension: 96 × 96 × 85 mm Cutout Dimension: 92 × 92 mm Weight: 350 grams (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
SSPRT/MTC

Model: MTC-02 Type: R, S Temperature Range: (a) 200 to 1500°C (b) 100 to 1200°C Accuracy: Class 1 (0.6°C or 0.1% of Temperature which ever is greater) Temperature Scale: ITS-90 Sheath Material: K-99 grade ceramic Thermocouple wire dia: 0.5mm Probe dia & Length: 6mm OD & 450mm Length Reference Junction Sheath Dimensions: 250mm Long, 5mm Diameter Cable Length Between sensor and CJS sensor: 700mm Cable Length from CJC sensor: 1.5 meter length Handle Dimension: 20mm OD & 100mm Length Calibration Certified: ISO/IEC 17025 Accredited 5 point

68179d65be22ee500d53ff54 Card 2

product image
SSPRT/MTC

Model: SSPRT Type: PT 100 Temperature Range: (a) -200 to 660°C (b) -80 to 600°C Temperature co-efficient: 0.00385 Ω / Ω /°C Stability: RO typical drift < 0.05°C after 100 hrs at 600 °C Thermal shock: RO typical drift < 0.01°C after 100 times from 25 to 600 °C Vibration: withstand 10 to 2000Hz at 20 G’s Recommended measuring current: 1mA Sheath Diameter: 6mm Sheath Length: 450mm Cable Length: 1500mm Outer Sheath: SS-316 End Connection: Flying Lead, 4 wire Case dimension (Approx.): 80mm(H) x 750mm(W) x 80mm(D) Gross weight (Approx.): 2.75kg (6 lbs) Calibration Option: 5 point NABL (or) Fixed point ITS-90 Resistance Vs Temperature chart

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model : DL 98HD Signal Input : RS 485(2 wire) Input Protocol : Modbus RTU Slave No. of. Channels : 32 FEATURES Ø It replace conventional 7 segment LED Ø Up to 32 input channels display Ø Custom selectable number of input No size limitation- Depends upon customer channels scope(HDMI compatible TV) Ø User configurable RS485 MODBUS setting Ø Low cost Ø User selectable title and Engineering units Ø Universal indicator for any type of industrial Ø Alarm set point and status indication process parameter Ø Adjustable display font size Ø Input from RS485 MODBUS RTU protocol Ø Custom adjustable colour, background, Ø HDMI output for display connectivity display, title and units Ø OLED TV display or any type of HDMI input Ø Inbuilt Data logging facility display device Ø Optional Ethernet output for computer Ø Pen drive option for Data download DISPLAY PARAMETER Temperature * Humidity * pressure * Flow & Total flow * Volume * Level * Production counting * RPM * m/min * Co2 * Volts * Current Power * pH * TDS * Conductivity, etc,. Application » Pharma industries » Automobile industries » Power industries » Petrochemical industries Food industries

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/500 Display: 2.8" True TFT with Touch screen Temperature Range: Amb. + 5 to 500 °C Radial uniformity: (Better than) ±0.05°C Resolution: 0.01 °C Stability: ±0.08 °C Temperature readout: °C Heating time: Amb to 500 --> 25 min Cooling time: 500 to 50--> 1 hr 20 min Stabilization time: 15 mins Well Dimension(dia. x height): 20 x 100 mm Well immersion depth: 90 mm Standard well holes in mm: 6.2 x 2nos Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 350 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.75 Kg

Still searching for
conductivity and temperature control system?