68179d65be22ee500d53ff54 Card 2

product image
Calibrators

“SANSEL” Series BCAL 1502 is a Micro controller Based Precision Temperature Calibrators Generates True Reference Temperature. The Temperature Controller of the Calibrators Uses a Auto Tune PID Control Algorithm. Infra red thermometer & online pyrometer calibration is performed by comparison of the temperature measured by UUC and target temperature indicated by the calibrator or using standard pyrometer. Focus the Unit Under Calibration (UUC) to be Calibrate to the target point given in BCAL 1502. Set the Temperature from the Touch screen display. Both True and set Temperature can be read. When Stabilization Occurs, Simply Read the Temperature and re-Calibrate the UUC. Model: BCAL 1502 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range: 500 to 1500 °C Resolution: 0.1°C Stability: ± 1°C Radial Uniformity: ± 1% of reading Bath Temperature Control: Digital Temperature Controller with Auto Tune PID Algorithm Temperature readout: °C Aperture area: 30mm Emissivity: 0.950 Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 4 KVA Dimension (W*D*H) (Approx.): 580mm W x 450mm D x 390mm H Instrument Weight (Approx): 45 kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1500 / 1500 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range : 500 to 1500 °C Resolution: 0.1°C Stability: ± 0.5°C Radial uniformity: Better than ± 0.5% of reading Bath Temperature Control: Digital Temperature Controller with Auto Tune PID Algorithm Heating time: 3 ½ Hrs ( Amb. to 1500 °C) Time to Stabilize: 30 minutes Well Dia: 50 mm Well Hole Depth: 240 mm Thermo Well Holes: 6, 8, 10, 14 in mm (Approx) PC Interface: RS 485 (optional) Power supply: 230V AC 50/60Hz (Optional 110V AC) Power Consumption: 3500 VA Dimension (L x W x H): 250 L X 410 W X 625 + 90 (wheel) H (mm) Instruments Weight: 57kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : Pcal 1300 / 20 bar Display : 128 x 64 COG Graphic LCD with White LED Back light Range (bar) : -1 to 20 bar Accuracy : ± 0.05%FS Resolution (bar) : 6 digit user selectable Instrument Port : 1/4' BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (WxHxD) mm Instrument Weight : 400gms (Appox.) Stability time : 1 to 2 mins Pressure units* (selectable) :bar, mbar, Mpa, kpa, kg/cm2, inHg,cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model : DL 98HD Signal Input : RS 485(2 wire) Input Protocol : Modbus RTU Slave No. of. Channels : 32 FEATURES Ø It replace conventional 7 segment LED Ø Up to 32 input channels display Ø Custom selectable number of input No size limitation- Depends upon customer channels scope(HDMI compatible TV) Ø User configurable RS485 MODBUS setting Ø Low cost Ø User selectable title and Engineering units Ø Universal indicator for any type of industrial Ø Alarm set point and status indication process parameter Ø Adjustable display font size Ø Input from RS485 MODBUS RTU protocol Ø Custom adjustable colour, background, Ø HDMI output for display connectivity display, title and units Ø OLED TV display or any type of HDMI input Ø Inbuilt Data logging facility display device Ø Optional Ethernet output for computer Ø Pen drive option for Data download DISPLAY PARAMETER Temperature * Humidity * pressure * Flow & Total flow * Volume * Level * Production counting * RPM * m/min * Co2 * Volts * Current Power * pH * TDS * Conductivity, etc,. Application » Pharma industries » Automobile industries » Power industries » Petrochemical industries Food industries

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501 / 300 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range : Amb. to 300°C Resolution: 0.01°C Stability: ± 0.03°C Radial uniformity: Better than ± 0.2°C Measure inputs: RTD-PT 50, 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms Temperature Readout: C Stabilization Time: 15 minutes Heating time: 30 mins (25 to 600°C) Cooling time: 50 mins (600 to 100°C ) Well Dimension: 30 x 150 mm (dia x height) Test sensor immersion depth: 140 mm Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1 PC Interface (optional): RS 232 with automatic calibration software UUC Sensor supply output: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (optional 110V AC) Power Consumption: 1200 VA Switch test: Provided Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.) Weight: 8.5 kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / -80 Display: 4.3 inch true TFT display with touch screen Working Range: -80 to -40 °C Resolution: 0.01 °C Stability: ± 0.03 °C Uniformity: ± 0.2 °C Bath Temperature Control: Digital Temperature Controller with FUZZY PID Multi Hole Well: Provided for Different type of Sensors, Sensor with Indicator & Thermometer Calibration Cooling medium: IPA Liquid Capacity: 5 Liters Testing Area: 100mm W x 100mm H x 190mm D Over all Dimension: 705mm L x 505mm W x 825mm H Power Supply: 230V AC ± 10% / 50Hz (Optional 110V44 AC) Weight: 80 kg (approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/30 bar Range (bar) :- 0.9 to 30 bar Pressure media : Air Pressure pump : HP-03 Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2 x ¼” BSP Female Pump dimension in mm (Approx.): 230 x 65 x 130 (L x H x W) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (W x H x D) mm Instrument Weight : 400gms (Approx.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units* (selectable) : bar, mbar, Mpa, kpa, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum & minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Switch test: Provided Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light (or) 9V DC adapter / 230V AC supply operated Pump Weight (Approx.) : 1250 grams Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/350 bar Range (bar) : 0 to 350 bar Pressure media : Oil & Water Pressure pump : HP-02A Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2x 1/2' BSP Female Pump dimension in mm (Appox.) : 310 x 80 x 165 (LxHxw) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 55 (W x H x D) mm Instrument Weight : 400gms (Appox.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units (selectable) : bar, mbar, Mpa, kpa, kg/cm2,inHg,cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Pressure overflow : FS X 2 (Max.) Pressure burst : FS X3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/1000 bar Range (bar) : 0- 1000 bar Pressure media : oil & Water Pressure pump : HP-01 Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2 x 1/2' BSP Female Pump dimension in mm (Approx.) : 340 x240 x320(L xH xW) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (W x H x D) mm Instrument Weight : 400gms (Approx.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light (or) 9V DC adapter /230V AC supply operated Pump Weight (Approx.) : 7500 grams Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)