Process Control Instruments

Model : HTP 196 Display : 3 line 4digit ,0.5” 7 segment LED Parameter: Temperature, Humidity & Absolute or differential (pressure) Range : 0 to 60°C / 0to100%RH / 0 to 2000mbar A or ±50pa Resolution :0.01°C / 0.1%RH / 1mbar A (or) 0.01pa Accuracy : ± 0.5°C / ± 3%RH / ± 0.5 % FS Set point: Low & High for all three Parameter Relay: 2 relay with 5A rating with selectable parameter Sensor : PT-100, Humidity & Temperature sensor with 2 meter cable Operating Environment: 0 to 50°C / 20 to 95%RH Non condensing Mounting : Wall mountable with key hole provision Supply : 90 to 270V AC / 50Hz Buzzer: Inbuilt Dimension : 100 mm W x 250 mm H x60 mm D Weight : 640gms

68179d65be22ee500d53ff54 Card 2

product image
NABL accreditated laboratory

We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABLNABL)national accreditation board for testing and calibration laboratories from Chennai, Tamil Nadu, India. Very Low Pressure ± 25 mbar Type of Instruments Calibrated Manometer Low pressure Transducer/Transmitter Gauges Differential Pressure Indicator/Tranmitter Pressure Data Logger Pressure switch Low pressure Calibrators,etc., Absolute Pressure: 0.60 bar to 2 bar Type of Instruments Calibrated Barometers Aneroid barometer Absolute gauges Absolute pressure sensor/Tranmitter Absolute pressure indicator/ controller Logger and Calibrators etc Vacuum: -0.1 bar to -0.99 bar Type of Instruments Calibrated Vacuum Gauge Vacuum Tranduer/Transmitter Vacuum Indicator/Controller/Switch Vacuum Logger Calibrators etc., Pressure(Hydraulic and Pneumatic) 1 bar to 1000 bar and 0.1 bar to 35 bar Type of Instruments Calibrated Pressure Calibrators Pressure Transducer Pressure Transmitter Digital Pressure Gauges Pressure Controller Pnueumatic pressure gauges Hydraulic Pressure gauges Differential pressure indicators, etc., Mass/Weight 1 mg to 50 kg Type of Instruments Calibrated(Accuracy class: E2,F1,F2,M1,M2,ETC.,) Standard weight box Weights, etc., Weighing Scale and Balance 1mg to 300 Kg Micro balance Analytical balance Digital balance Weighing Scale Volume 1µl to 5l Type of Instruments Calibrated Pipette Burette Flask beaker

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model : HTP 196 Display : 3 line 4digit ,0.5” 7 segment LED Range : 0 to 60°C / 0to100%RH/ 0 to 2000mbarA Resolution : 0.01 or 0.1°C / 0.1% RH / 1 mbar Accuracy : ± 0.5 °C / ± 3%RH / ± 0.5 % FS Mounting : Wall mountable Power supply : 90 to 270V AC Dimension : 100 mm W x 250 mm H x60 mm D Weight : 640gms Sensor : P T-100, Humidity & Pressure sensor with 2 meter cable

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : Pcal 1300 / 20 bar Display : 128 x 64 COG Graphic LCD with White LED Back light Range (bar) : -1 to 20 bar Accuracy : ± 0.05%FS Resolution (bar) : 6 digit user selectable Instrument Port : 1/4' BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (WxHxD) mm Instrument Weight : 400gms (Appox.) Stability time : 1 to 2 mins Pressure units* (selectable) :bar, mbar, Mpa, kpa, kg/cm2, inHg,cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model : DL 98HD Signal Input : RS 485(2 wire) Input Protocol : Modbus RTU Slave No. of. Channels : 32 FEATURES Ø It replace conventional 7 segment LED Ø Up to 32 input channels display Ø Custom selectable number of input No size limitation- Depends upon customer channels scope(HDMI compatible TV) Ø User configurable RS485 MODBUS setting Ø Low cost Ø User selectable title and Engineering units Ø Universal indicator for any type of industrial Ø Alarm set point and status indication process parameter Ø Adjustable display font size Ø Input from RS485 MODBUS RTU protocol Ø Custom adjustable colour, background, Ø HDMI output for display connectivity display, title and units Ø OLED TV display or any type of HDMI input Ø Inbuilt Data logging facility display device Ø Optional Ethernet output for computer Ø Pen drive option for Data download DISPLAY PARAMETER Temperature * Humidity * pressure * Flow & Total flow * Volume * Level * Production counting * RPM * m/min * Co2 * Volts * Current Power * pH * TDS * Conductivity, etc,. Application » Pharma industries » Automobile industries » Power industries » Petrochemical industries Food industries

68179d65be22ee500d53ff54 Card 2

product image
NABL accreditated laboratory

We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India. Voltage : 1 mV to 1000 V AC/DC Current : 10 µA to 1000 A AC/DC TC, RTD : PT-100,J,K,R,S,T,E,B,N Resistance : 1 ohm to 100 G ohm Frequency : 1 Hz to 10 MHz Capacitance : 10 nF to 1 µF Type of Instruments Calibrated Multi Product Calibrator Multi Function Calibrator Digital Multimeter Frequency Counter Signal Generator Decade Resistance Box Meggar Power Supplies Analog Voltmeter/Ammeter Digital Voltmeter/Ammeter AC/DC Clamp meter Temperature Indicator/controller I/P,P/I Convertor Valve Positioner Process Flow Indicator LCR Meter Process Flow Totalizer, etc., High Voltage 1 kV to 30 kV Type of Instruments Calibrated AC/DC High Voltage source Timer 1s to 99999s Type of Instruments Calibrated Digital Timer Analog Timer Stop Watch, etc., Note: Price May vary based on quantity and instruments

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / -80 Display: 4.3 inch true TFT display with touch screen Working Range: -80 to -40 °C Resolution: 0.01 °C Stability: ± 0.03 °C Uniformity: ± 0.2 °C Bath Temperature Control: Digital Temperature Controller with FUZZY PID Multi Hole Well: Provided for Different type of Sensors, Sensor with Indicator & Thermometer Calibration Cooling medium: IPA Liquid Capacity: 5 Liters Testing Area: 100mm W x 100mm H x 190mm D Over all Dimension: 705mm L x 505mm W x 825mm H Power Supply: 230V AC ± 10% / 50Hz (Optional 110V44 AC) Weight: 80 kg (approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/30 bar Range (bar) :- 0.9 to 30 bar Pressure media : Air Pressure pump : HP-03 Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2 x ¼” BSP Female Pump dimension in mm (Approx.): 230 x 65 x 130 (L x H x W) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (W x H x D) mm Instrument Weight : 400gms (Approx.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units* (selectable) : bar, mbar, Mpa, kpa, kg/cm², inHg, cmHg, mmHg, mH₂O, ftH₂O, inH₂O, cmH₂O, mmH₂O Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum & minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Switch test: Provided Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light (or) 9V DC adapter / 230V AC supply operated Pump Weight (Approx.) : 1250 grams Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/350 bar Range (bar) : 0 to 350 bar Pressure media : Oil & Water Pressure pump : HP-02A Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2x 1/2' BSP Female Pump dimension in mm (Appox.) : 310 x 80 x 165 (LxHxw) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 55 (W x H x D) mm Instrument Weight : 400gms (Appox.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units (selectable) : bar, mbar, Mpa, kpa, kg/cm2,inHg,cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Pressure overflow : FS X 2 (Max.) Pressure burst : FS X3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)