68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1500 / 1500 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range : 500 to 1500 °C Resolution: 0.1°C Stability: ± 0.5°C Radial uniformity: Better than ± 0.5% of reading Bath Temperature Control: Digital Temperature Controller with Auto Tune PID Algorithm Heating time: 3 ½ Hrs ( Amb. to 1500 °C) Time to Stabilize: 30 minutes Well Dia: 50 mm Well Hole Depth: 240 mm Thermo Well Holes: 6, 8, 10, 14 in mm (Approx) PC Interface: RS 485 (optional) Power supply: 230V AC 50/60Hz (Optional 110V AC) Power Consumption: 3500 VA Dimension (L x W x H): 250 L X 410 W X 625 + 90 (wheel) H (mm) Instruments Weight: 57kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

“SANSEL” Series BCAL 1502 is a Micro controller Based Precision Temperature Calibrators Generates True Reference Temperature. The Temperature Controller of the Calibrators Uses a Auto Tune PID Control Algorithm. Infra red thermometer & online pyrometer calibration is performed by comparison of the temperature measured by UUC and target temperature indicated by the calibrator or using standard pyrometer. Focus the Unit Under Calibration (UUC) to be Calibrate to the target point given in BCAL 1502. Set the Temperature from the Touch screen display. Both True and set Temperature can be read. When Stabilization Occurs, Simply Read the Temperature and re-Calibrate the UUC. Model: BCAL 1502 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range: 500 to 1500 °C Resolution: 0.1°C Stability: ± 1°C Radial Uniformity: ± 1% of reading Bath Temperature Control: Digital Temperature Controller with Auto Tune PID Algorithm Temperature readout: °C Aperture area: 30mm Emissivity: 0.950 Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 4 KVA Dimension (W*D*H) (Approx.): 580mm W x 450mm D x 390mm H Instrument Weight (Approx): 45 kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / -80 Display: 4.3 inch true TFT display with touch screen Working Range: -80 to -40 °C Resolution: 0.01 °C Stability: ± 0.03 °C Uniformity: ± 0.2 °C Bath Temperature Control: Digital Temperature Controller with FUZZY PID Multi Hole Well: Provided for Different type of Sensors, Sensor with Indicator & Thermometer Calibration Cooling medium: IPA Liquid Capacity: 5 Liters Testing Area: 100mm W x 100mm H x 190mm D Over all Dimension: 705mm L x 505mm W x 825mm H Power Supply: 230V AC ± 10% / 50Hz (Optional 110V44 AC) Weight: 80 kg (approx.)

68179d65be22ee500d53ff54 Card 2

product image
NABL accreditated laboratory

We are a leading service provider for calibration of various types of parameters in all industries and our lab is accredited by (NABL)National Accreditation Board for Testing and Calibration laboratories from Chennai, Tamil Nadu, India. Temperature(Contact) Range from -80 deg C to 1500 deg c Type of Instruments Calibrated: Digital Thermometer Glass Thermometer Dry block Calibrators Thermocouple and RTD probes Thermistors Temperature Recorder Temperature Scanner/Data logger Temperature Indicator with sensor Temperature Gauge Temperature Transmitter Temperature bath,etc., Mapping and Validation for single or multi point Freezer incubator oven furnance Storage rooms clean rooms dryer cold rooms Environmental chambers Humidity Indicator/chamber, etc., Temperature(Non-Contact)Range from 0 deg c to 1500 deg c Type of Instruments Calibrated Non-Contact Pyrometers IR thermometer Black Body Source, ect., Humidity: Range from 5 to 60 deg c & 10 to 95% Type of Instruments Calibrated Humidity sensors/Transmitter Humidity/Temperature logger Analog hygrometer

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : HCAL 1104U Display: 7” True colour TFT LCD Display with Touch screen Control Range : 5 to 60°C / 3 to 95 % RH* Dew point Temperature range (psychometric calculated) : -30°C to 45°C Psychometric calculated indication : Dew / Frost point ( Dp / Fp ) Wet Bulb Temperature ( Tw ) Vapour partial pressure ( E ) Vapour Saturation pressure ( Ew ) Mixing ratio by weight (dry) ( g / kg ) Enthalpy ( H ) ( KJ / kg ) Specific Humidity (moisture) ( g / kg ) Absolute Humidity (moisture) ( g / m³ ) Volume mixing ratio (dry) ( ppm ) Calculation method : WMO method Resolution : 0.01 °C / 0.01% RH Display stability : Better than ± 0.03 °C / ± 0.15% RH Chamber stability @25°C ** Temperature: ± 0.1°C, Humidity: ± 0.3 % RH Chamber Uniformity @25°C** Temperature: ± 0.2°C, Humidity: ± 0.5 % RH Test sensor insert port: Inter changeable Acrylic door is provided on front side of the chamber with pg21 gland (cable or sensor size range from 13 to 18mm) x 3nos External Humidifier Water tank capacity: 6 litres (approx.)(NOTE : 3 liter filling is enough for our application) Humidifier Liquid: Distilled water Humidifying Time:2 %RH / sec (50 to 90 % RH) Dehumidifying Time: 6 %RH / sec (50 to 10 % RH) Test chamber area: 230mm DIA x 170mm D (Approx) Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 1000 VA Construction: Inner chamber SS 310 / outer MS powder coating Overall Dimension: 436mm L x 676mm W x 368mm H (Approx.) Weight: 46 kg (without Accessories) + 6 kg (standard accessories) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Analytical Instruments

Model : pH 600 - 1 Display : 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display Input Impedance : >10 Ohms Range : -2 to 16 pH Resolution : 0.01 pH Temperature sensor: RTD - PT 100 (3 wire) Temp. Compensation: Manual / Automatic (-20.0 to +150.0ºC) Electrode Input: Combined Electrode with BNC Attachment Accuracy : ± 0.01 pH ± 1 digit Set Point - 1 & 2: Two Set Point with 6 Relay Status Selectable Relay Output : Relay - 1 for Setpoint - 1, Relay - 2 for Setpoint - 2 with 5A Rating Relay Hysteresis : 0 to 5 pH (user adjustable)(only for High & Low control modes) Relay Cyclic delay : 0 to 100 seconds (user adjustable)(only for High & Low control modes) Alarm Output(optional) inbuilt audible buzzer with front key reset Optional Re. Tx. output Galvanically Isolated : 4 - 20 mA Optional Comm. output Isolated RS 485 Comm. Protocol MODBUS RTU Operating Environment : -10 to 50ºC / 10 to 95 % RH Non Condensing Power Supply : 90 to 270V AC / DC 50Hz Dimension : 96 x 96 x 85 mm. Cutout Dimension : 92 x 92 mm Weight : 500 grams (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Analytical Instruments

Model: TDS 602-1 Display: 4 + 4 Digit 0.5” & 0.39” 7-Segment Red LED Display Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range) Range (any one): 1–20 ppm, 5–200 ppm, 10–2000 ppm, 1–20 ppt, 5–200 ppt Accuracy: ±1% of range +1 digit Resolution: 0.01 ppm to 0.1 ppt (depends on range) Temperature Sensor: RTD – PT100 (3-wire) Temperature Coefficient: 0 to 3% / °C (user adjustable) Temperature Compensation: Manual / Automatic (-20.0 to +150.0 °C) Electrode Input: Conductivity cell on rear panel Set Point – 1 & 2: Two set points with 6 relay status selectable Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating Relay Hysteresis: 0 to 500 counts (user adjustable) (only for High & Low control modes) Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes) Alarm Output (optional): Inbuilt audible buzzer with front-key reset Optional Re-Tx Output: Galvanically isolated 4–20 mA Optional Comm. Output: Isolated RS-485 Communication Protocol: MODBUS RTU Operating Environment: -10 to 50 °C / 10 to 95% RH non-condensing Power Supply: 90 to 270 V AC / DC, 50 Hz Enclosure: ABS plastics Dimension: 96 × 96 × 85 mm Cutout Dimension: 92 × 92 mm Weight: 350 grams (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: CC 603 - 1 Display: 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display Range (any one): 1 – 20µS, 5 – 200µS, 10 to 2000µS, 1 to 20mS, 5 to 200mS Resolution: 0.01µS to 0.1mS (depends on range) Accuracy: ±1% of range ±1 digit Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range) Temperature Sensor: RTD – PT 100 (3 wire) Temperature Co-efficient: 0 to 3% / °C (user adjustable) Temperature Compensation: Manual / Automatic (-20.0 to +150.0°C) Electrode Input: Conductivity cell on rear panel Set Point – 1 & 2: Two set points with 6 relay status selectable Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating Relay Hysteresis: 0 to 500 counts (user adjustable) (only for High & Low control modes) Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes) Alarm Output (optional): Inbuilt audible buzzer with front key reset Optional Re-Tx Output: Galvanically isolated 4 – 20 mA Optional Comm. Output: Isolated RS-485 Comm. Protocol: MODBUS RTU Operating Environment: -10 to 50°C / 10 to 95% RH non-condensing Power Supply: 90 to 270V AC / DC, 50Hz Dimension: 96 × 96 × 85 mm Cutout Dimension: 92 × 92 mm Weight: 350 grams (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
SSPRT/MTC

Model: MTC-02 Type: R, S Temperature Range: (a) 200 to 1500°C (b) 100 to 1200°C Accuracy: Class 1 (0.6°C or 0.1% of Temperature which ever is greater) Temperature Scale: ITS-90 Sheath Material: K-99 grade ceramic Thermocouple wire dia: 0.5mm Probe dia & Length: 6mm OD & 450mm Length Reference Junction Sheath Dimensions: 250mm Long, 5mm Diameter Cable Length Between sensor and CJS sensor: 700mm Cable Length from CJC sensor: 1.5 meter length Handle Dimension: 20mm OD & 100mm Length Calibration Certified: ISO/IEC 17025 Accredited 5 point