Model: pH 302
Display: 16 Character x 2 line LCD with Backlight
Range: 0 to 14 pH / -1999 to +1999 mV /0 – 150°C
Resolution: 0.01 pH / 1 mV / 0.1°C
Accuracy: ± 0.01 pH ± 1 digit / ± 1 mV ± 1 digit /± 0.5°C ± 1 digit
Input Impedance: > 10¹² Ohms
Temperature Compensation: 0 to 150°C Manual / Automatic
Electrode: Combined pH Electrode with BNC attachment
Temperature sensor: Provided with 3 pin female socket
pH / ORP Input connection: BNC socket
Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing
Temperature connection: 3 pin male socket
Power supply: 230V AC / 50 Hz ± 10%
Overall Dimensions in mm: 190 x 185 x 75 ( L x B x H )
Instrument weight: 1.7 kg (Approx.)
Model : HCAL 1104U
Display: 7” True colour TFT LCD Display with Touch screen
Control Range : 5 to 60°C / 3 to 95 % RH*
Dew point Temperature range (psychometric calculated) : -30°C to 45°C
Psychometric calculated indication : Dew / Frost point ( Dp / Fp )
Wet Bulb Temperature ( Tw )
Vapour partial pressure ( E )
Vapour Saturation pressure ( Ew )
Mixing ratio by weight (dry) ( g / kg )
Enthalpy ( H ) ( KJ / kg )
Specific Humidity (moisture) ( g / kg )
Absolute Humidity (moisture) ( g / m³ )
Volume mixing ratio (dry) ( ppm )
Calculation method : WMO method
Resolution : 0.01 °C / 0.01% RH
Display stability : Better than ± 0.03 °C / ± 0.15% RH
Chamber stability @25°C **
Temperature: ± 0.1°C, Humidity: ± 0.3 % RH
Chamber Uniformity @25°C**
Temperature: ± 0.2°C, Humidity: ± 0.5 % RH
Test sensor insert port: Inter changeable Acrylic door is provided on front side of the chamber with pg21 gland (cable or sensor size range from 13 to 18mm) x 3nos
External Humidifier Water tank capacity: 6 litres (approx.)(NOTE : 3 liter filling is enough for our application)
Humidifier Liquid: Distilled water
Humidifying Time:2 %RH / sec (50 to 90 % RH)
Dehumidifying Time: 6 %RH / sec (50 to 10 % RH)
Test chamber area: 230mm DIA x 170mm D (Approx)
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption: 1000 VA
Construction: Inner chamber SS 310 / outer MS powder coating
Overall Dimension: 436mm L x 676mm W x 368mm H (Approx.)
Weight: 46 kg (without Accessories) + 6 kg (standard accessories) (Approx.)
Model : CC 100
Display : 0.5” 4 Digit 7 segment Red LED
Range :0 to 9999 counts
Input : Count Pulse for Electronic Marker Pen
Resolution : 1 count
Disk Diameter : 110 mm
Magnification : x1.7 Surface
Count Reset : Push Button Provided on front panel
Input connection : 2 Pin Female Socket
Operating Environment : 0 to 50 °C / 20 to 95 % RH non condensing
Power supply : 230V AC / 50 Hz ± 10%
Overall Dimension in mm : 220 x 200 x 105 (L x B x H)
Instrument Weight : 2.5 kg (Approx.)
Model :DN 1000
Display : 0.5” 3 ½ Digit 7 segment Red LED
Range : 0 to 19.9 & 199.9 NTU
Resolution : 0.1 NTU
Detector : Photo Diode
Test Tube : 30mm Dia Clear Glass Test tube x 4 nos
Light Source : High Intensity 5mm White LED
Operating Environment : 0 to 50 °C / 20 to 95 % RH non condensing
Power supply : 230V AC / 50 Hz ± 10%
Overall Dimension in mm : 220 x 200 x 110 (L x B x H)
Instrument Weight : 1.7 kg (Approx.)
Model : TCAL 1503 / -100
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -100°C to 40°C @20°C to 30°C Ambient
Resolution : 0.01 °C
Block Stability (30 mins) : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.05 °C at full range
Temperature Read out : °C / °F (selectable)
Heating time :
25°C to 40°C : 30 min
-100 to 25°C : 80 min
Cooling Time: 25°C to -100°C : 85 min
40 to 25°C : 12 min
Stabilization time : 15 minutes
Insert Dia. x Height: 30 x 120 mm
Test sensor immersion depth: 115 mm
Standard well holes in mm : Insert No. 1 : 5.1, 6.2, 6.2 & 8.1
Insert No. 2 : 6.2, 6.2 & 10.2
Measure inputs: RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, V, mV, Ohms
Cold junction Accuracy: ± 0.3°C
Communication: RS 485 MODBUS
Switch Test: Provided
Sensor supply output: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption : 500 VA
Overall Dimension in mm : 356 x 210 x 534 (L x B x H)(Approx.)
Instrument Weight :15.9 kg(with well insert)(Approx.)
Model : Pcal 1300 / 20 bar
Display : 128 x 64 COG Graphic LCD with White LED Back light
Range (bar) : -1 to 20 bar
Accuracy : ± 0.05%FS
Resolution (bar) : 6 digit user selectable
Instrument Port : 1/4' BSP Male x 10 mm long
Instrument dimension : 100 x 100 x 55 (WxHxD) mm
Instrument Weight : 400gms (Appox.)
Stability time : 1 to 2 mins
Pressure units* (selectable) :bar, mbar, Mpa, kpa, kg/cm2, inHg,cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o
Pressure Zero : One touch zero provided on front key
Pressure Peak : Maximum &minimum with user reset option
Pressure overflow : FS X 2 (Max.)
Pressure burst : FS X3 (Max.)
Temp.Measure : RTD-PT 100 (2,3,4, wire selectable)
Temp. Range : -199.999 to 850.000
Switch test : Provided
mA Measure : 0-24 mA (scalable)
Display scale : -99999 to 99999 counts (for mA measure input)
Display Hold : One touch hold provided on front key
Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours
with out back light(or) 9V DC adapter /230V AC supply operated
Pump Weight (gms)(Approx.) : 700
Pc Interface : RS 485
Pc Software : Windows based semi automatic calibration software (optional)
Model: ORP 300
Display: 0.5” 3 ½ Digit 7 segment Red LED
Range: -1999 to +1999 mV
Resolution: 1 mV
Accuracy: ± 1 mV ± 1 digit
Input Impedance: > 10¹² Ohms
Input connection: BNC socket
Electrode: ORP Electrode with BNC attachment
Operating Environment: 0 to 50 °C / 20 to 95 % RH non condensing
Power supply: 230V AC / 50 Hz ± 10%
Overall Dimensions in mm: 185 x 235 x 65 (L x B x H)
Instrument weight: 1.6 kg (Approx.)
Model: PIJ – 541 B1
Display: 2” or 4” or 8” 6 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, PT 1000, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -199999 to 199999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.99 to 850.00°C / -327.5 to 1562.0 °F) RTD - PT 1000 (-50.0 to 400.0°C / -58.0 to 752.0 °F) TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 1000°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (option
al): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Monitoring, Data logging, Report & Graph (Optional)
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 611 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 5.5 (or) 8.5 kg
Model: PIJ – 542 A1
Display: 2” or 4” or 8” 4 Digit 7 segment RED LED*
Accuracy: ± 0.1 % of FS
Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable)
Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E
Analog display range: -1999 to 9999 (H & L Limit programmable)
Temperature range (H & L Limit programmable):
RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F)
TC - J (- 200 to 1200°C / -328 to 2192°F)
TC - K (- 200 to 1372°C / -327 to 2501°F)
TC - R (- 40 to 1768°C / -40 to 3214°F)
TC - S (- 40 to 1768°C / -40 to 3214°F)
TC - T (- 200 to 400°C / -328 to 752°F)
TC - B (300 to 1820°C / 572 to 3308°F)
TC - N (-200 to 1300°C / -327 to 2372°F)
TC - E ( -200 to 999.9°C / -327 to 1832°F)
Unit selection: °C / °F ( for RTD & TC inputs)
Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable)
Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable)
Filter constant: 1 – 100% (Adjustable)
Display hold option: Peak, hold & average (any one selectable)
Hold delay: 0 - 999 sec (selectable)
Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay
Temperature drift: ≤ 0.1% FS/°C (typical 50 ppm)
Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC
PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol
PC interface software: Optional
Sensor Supply (external): 24 V DC ±10% @ 100 mA
Power supply: 230 V AC / 50 Hz
Overall dimension: 428 x 171 x 85 (L x H x D) mm (Approx.)
Housing : MS Powder coating
Mounting: Wall or sealing with 360 º rotatable clamp
Operating environment: 0 - 50°C / 5 to 95% RH Non condensing
Weight (Approx.): 4.5 kg