Chennai
08048035791
+917299972093

'1 to 2 mins'

Items tagged with '1 to 2 mins'

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : Pcal 1300 / 20 bar Display : 128 x 64 COG Graphic LCD with White LED Back light Range (bar) : -1 to 20 bar Accuracy : ± 0.05%FS Resolution (bar) : 6 digit user selectable Instrument Port : 1/4' BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (WxHxD) mm Instrument Weight : 400gms (Appox.) Stability time : 1 to 2 mins Pressure units* (selectable) :bar, mbar, Mpa, kpa, kg/cm2, inHg,cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501 / 1200 Display: 4.3” True TFT LCD Display with Touch screen Temperature Range: 300 to 1200°C Resolution: 0.1°C Stability: Better than ± 0.5°C Radial uniformity: Better than ± 2°C Stabilization Time: 30 minutes Temperature readout: °C Heating time: 50 mins (Amb. to 1200°C) Cooling time: 120 mins (1200 to 100°C ) Well Dimension: 39 x 180 x 140 mm (dia x height x depth) Standard well holes in mm: 5.2, 6.2, 6.2, 10.1 & 12.1 Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 1900 VA Overall Dimension in mm: 340 x 175 x 425 (L x B x H) (Approx.) Weight: 18 kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

MODEL : Pcal 1300/2 bar Range (bar) : -0.9 to 2 bar Pressure media : Air Pressure pump : HP-04 ,HP-03 Display : 128 x 64 COG Graphic LCD with White LED Back light Pressure Port : 2 x1/4 ' BSP Female Pump dimension in mm (Appox.) : 170 x 45 (Height x Dia) Resolution (bar) : 6 digit user selectable Instrument Port : 1/4 BSP Male x 10 mm long Instrument dimension : 100 x 100 x 55 (W x H x D) mm Instrument Weight : 400gms (Appox.) Stability time : 1 to 2 mins Accuracy : ±0.05%FS Pressure units (selectable) : bar, mbar, Mpa, kpa, kg/cm2, inHg, cmHg,mmHg,mH₂o, ftH₂o,inH₂o, cmH₂o,mmH₂o Pressure Zero : One touch zero provided on front key Pressure Peak : Maximum &minimum with user reset option Pressure overflow : FS X 2 (Max.) Pressure burst : FS X 3 (Max.) Temp.Measure : RTD-PT 100 (2,3,4, wire selectable) Temp. Range : -199.999 to 850.000 Switch test : Provided mA Measure : 0-24 mA (scalable) Display scale : -99999 to 99999 counts (for mA measure input) Display Hold : One touch hold provided on front key Power Supply : 9V DC ±5% / 200mAh Rechargeable battery with battery life 4hours with out back light(or) 9V DC adapter /230V AC supply operated Pump Weight (gms)(Approx.) : 700 Pc Interface : RS 485 Pc Software : Windows based semi automatic calibration software (optional)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1401 / 1200 Display: 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys Temperature Range: 500 to 1200°C Resolution: 1°C Stability: ± 2°C Radial Uniformity: Better than: ± 2°C Temperature readout: °C Heating time: 50 mins (Amb. To 1200 °C) Cooling time: 120 mins (1200 to 100 °C) Stabilization time: 30 minutes Well Dimension (dia. X height): 39 x 150 mm Standard well holes in mm: 5.2, 6.2, 6.2, 10.1 & 12.1 Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 1900 VA Overall Dimension in mm: 340 x 175 x 425 (L x B x H)(Approx.) Instrument Weight: 18 kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / 250 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range: Amb. +5 to 250°C Resolution: 0.01°C Stability: ± 0.03°C Accuracy: Better than ± 0.3°C Stabilization Time: 45 minutes Heating time: 60 mins (Amb. to 250°C) Cooling time: 90 mins (250 to 50°C ) Chamber Dimension: 80 x 140 mm (dia X depth) Testing area: 60 x 120 mm (dia X depth) Temperature medium: Silicon oil (200cs recommended) Measure inputs: RTD-PT 100, PT 1000 / TC-J, K, R, S, T, E, B , N / mA /mV / ohms PC Interface: RS 485 (optional) Power supply: 230V AC or 110V AC 50/60Hz Power Consumption: 1200 VA Switch test: Provided Dimension in mm: 340 x 175 x 425 (L x W x H) (Approx.) Weight (Approx.): 12 kg (without oil)

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: PIJ – 541 B1 Display: 2” or 4” or 8” 6 Digit 7 segment RED LED* Accuracy: ± 0.1 % of FS Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable) Temperature inputs: RTD - PT 100, PT 1000, Thermocouple - J, K, R, S, T, B, N, E Analog display range: -199999 to 199999 (H & L Limit programmable) Temperature range (H & L Limit programmable): RTD - PT 100 (-199.99 to 850.00°C / -327.5 to 1562.0 °F) RTD - PT 1000 (-50.0 to 400.0°C / -58.0 to 752.0 °F) TC - J (- 200 to 1200°C / -328 to 2192°F) TC - K (- 200 to 1372°C / -327 to 2501°F) TC - R (- 40 to 1768°C / -40 to 3214°F) TC - S (- 40 to 1768°C / -40 to 3214°F) TC - T (- 200 to 400°C / -328 to 752°F) TC - B (300 to 1820°C / 572 to 3308°F) TC - N (-200 to 1300°C / -327 to 2372°F) TC - E ( -200 to 1000°C / -327 to 1832°F) Unit selection: °C / °F ( for RTD & TC inputs) Analog input display resolution: 0.0001 / 0.001 / 0.01 / 0.1 / 1 (Selectable) Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable) Filter constant: 1 – 100% (Adjustable) Display hold option: Peak, hold & average (any one selectable) Hold delay: 0 - 999 sec (selectable) Relay Output (option al): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol PC interface software: Monitoring, Data logging, Report & Graph (Optional) Sensor Supply (external): 24 V DC ±10% @ 100 mA Power supply: 230 V AC / 50 Hz Overall dimension: 611 x 171 x 85 (L x H x D) mm (Approx.) Housing : MS Powder coating Mounting: Wall or sealing with 360 º rotatable clamp Operating environment: 0 - 50°C / 5 to 95% RH Non condensing Weight (Approx.): 5.5 (or) 8.5 kg

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: PIJ – 542 A1 Display: 2” or 4” or 8” 4 Digit 7 segment RED LED* Accuracy: ± 0.1 % of FS Analog inputs: 4 – 20 mA, 0 - 20 mA, 0 to 70 mV, 0 to 10 V DC, 0 – 400 Ω (H & L Limit Programmable) Temperature inputs: RTD - PT 100, Thermocouple - J, K, R, S, T, B, N, E Analog display range: -1999 to 9999 (H & L Limit programmable) Temperature range (H & L Limit programmable): RTD - PT 100 (-199.9 to 850.0°C / -199.9 to 999.9 °F) TC - J (- 200 to 1200°C / -328 to 2192°F) TC - K (- 200 to 1372°C / -327 to 2501°F) TC - R (- 40 to 1768°C / -40 to 3214°F) TC - S (- 40 to 1768°C / -40 to 3214°F) TC - T (- 200 to 400°C / -328 to 752°F) TC - B (300 to 1820°C / 572 to 3308°F) TC - N (-200 to 1300°C / -327 to 2372°F) TC - E ( -200 to 999.9°C / -327 to 1832°F) Unit selection: °C / °F ( for RTD & TC inputs) Analog input display resolution: 0.001 / 0.01 / 0.1 / 1 (Selectable) Temperature resolution: 0.1 / 1 °C / °F (optional 0.01 for RTD - PT 100 I/P up to 99.99 °C Factory presetable) Filter constant: 1 – 100% (Adjustable) Display hold option: Peak, hold & average (any one selectable) Hold delay: 0 - 999 sec (selectable) Relay Output (optional): 2 Relay (5A rated) with 6 Relay Status Selection, Adjustable, Hysteresis, Cyclic Delay Temperature drift: ≤ 0.1% FS/°C (typical 50 ppm) Re Transmission (optional): Opto Isolated Analog Output 4 - 20 mA or 0 - 10V DC PC communication (optional): RS 485 (2 wire) MODBUS RTU protocol PC interface software: Optional Sensor Supply (external): 24 V DC ±10% @ 100 mA Power supply: 230 V AC / 50 Hz Overall dimension: 428 x 171 x 85 (L x H x D) mm (Approx.) Housing : MS Powder coating Mounting: Wall or sealing with 360 º rotatable clamp Operating environment: 0 - 50°C / 5 to 95% RH Non condensing Weight (Approx.): 4.5 kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/500 Display: 2.8" True TFT with Touch screen Temperature Range: Amb. + 5 to 500 °C Radial uniformity: (Better than) ±0.05°C Resolution: 0.01 °C Stability: ±0.08 °C Temperature readout: °C Heating time: Amb to 500 --> 25 min Cooling time: 500 to 50--> 1 hr 20 min Stabilization time: 15 mins Well Dimension(dia. x height): 20 x 100 mm Well immersion depth: 90 mm Standard well holes in mm: 6.2 x 2nos Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 350 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.75 Kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/300 Display: 2.8" True TFT with Touch screen Temperature Range: Amb. + 5 to 300 °C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.04 °C Temperature readout: °C Heating time: Amb to 300 -->23 min Cooling time: 300 to 50-->30 min Stabilization time: 15 mins Well Dimension(dia. x height): 20 x 100 mm Well immersion depth: 90 mm Standard well holes in mm: 6.2 x 2nos Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 250 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 2.75 Kg

Still searching for
1 to 2 mins?