Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108048035791 (International callers) or 08048035791 (Indian callers).
Model: TCAL 1404/300
Display: 2.8" True TFT with Touch screen
Temperature Range: Amb. + 5 to 300 °C
Radial uniformity: (Better than) ±0.03°C
Resolution: 0.01 °C
Stability: ±0.04 °C
Temperature readout: °C
Heating time: Amb to 300 -->23 min
Cooling time: 300 to 50-->30 min
Stabilization time: 15 mins
Well Dimension(dia. x height): 20 x 100 mm
Well immersion depth: 90 mm
Standard well holes in mm: 6.2 x 2nos
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power consumption: 250 w
Overall Dimension in mm: 170 x 95 x 183 mm
Instrument Weight: 2.75 Kg
Model: TCAL 1501 / 300
Display: 4.3 inch True TFT LCD Display with Touch screen
Temperature Range : Amb. to 300°C
Resolution: 0.01°C
Stability: ± 0.03°C
Radial uniformity: Better than ± 0.2°C
Measure inputs: RTD-PT 50, 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms
Temperature Readout: C
Stabilization Time: 15 minutes
Heating time: 30 mins (25 to 600°C)
Cooling time: 50 mins (600 to 100°C )
Well Dimension: 30 x 150 mm (dia x height)
Test sensor immersion depth: 140 mm
Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1
PC Interface (optional): RS 232 with automatic calibration software
UUC Sensor supply output: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (optional 110V AC)
Power Consumption: 1200 VA
Switch test: Provided
Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.)
Weight: 8.5 kg (without well insert) (Approx.)
Model : TCAL 1503 / -100
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -100°C to 40°C @20°C to 30°C Ambient
Resolution : 0.01 °C
Block Stability (30 mins) : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.05 °C at full range
Temperature Read out : °C / °F (selectable)
Heating time :
25°C to 40°C : 30 min
-100 to 25°C : 80 min
Cooling Time: 25°C to -100°C : 85 min
40 to 25°C : 12 min
Stabilization time : 15 minutes
Insert Dia. x Height: 30 x 120 mm
Test sensor immersion depth: 115 mm
Standard well holes in mm : Insert No. 1 : 5.1, 6.2, 6.2 & 8.1
Insert No. 2 : 6.2, 6.2 & 10.2
Measure inputs: RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, V, mV, Ohms
Cold junction Accuracy: ± 0.3°C
Communication: RS 485 MODBUS
Switch Test: Provided
Sensor supply output: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption : 500 VA
Overall Dimension in mm : 356 x 210 x 534 (L x B x H)(Approx.)
Instrument Weight :15.9 kg(with well insert)(Approx.)
Model : TCAL 1503 / -40
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -40 to 120°C @23°C Ambient
Resolution : 0.01 °C
Block Stability : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.02°C at full range
Block Axial Uniformity (upto 40mm) : ± 0.18°C at -45°C
± 0.1°C at 0°C
± 0.05°C at 50°C
± 0.11°C at 100°C
± 0.17°C at 120°C
Temperature Read out : °C / °F (selectable)
Loading effect: Better than ± 0.08°C
hysteresis: Better than ± 0.03°C
Cooling time :
30 mins (25 to -45 °C)
15 mins (25 to -30 °C)
65 mins (120 to 25 °C)
Heating time : 25 mins (25 to 120 °C)
75 mins (-45 to 120 °C)
52 mins (-45 to 25 °C)
Stabilization time: 10 minutes
Insert (Dia. x Height): 30 x 160 mm
Test sensor immersion depth: 130 mm
Standard well holes in mm: Insert No. 1 → 5.1, 6.2, 6.2 & 8.1, Insert No. 2 → 6.2, 6.2 & 10.2
Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms
Cold junction Accuracy: ± 0.3°C
UUC Sensor supply input: 24V DC ± 10% / 50mA max.
Power supply: 230V AC ± 10% / 50Hz (optional 110V AC)
Power Consumption: 500 VA
Switch Test : Provided
Overall Dimension in mm: 390 x 185 x 356 (L x B x H) (Approx.)
Weight: 17.3 kg (with well insert) (Approx.)
Model : TCAL 1503 / -35
Display : 4.3” True colour TFT display with touch screen
Temperature Range : -35 to 120 °C @ 23 °C Ambient
Resolution : 0.01 °C
Block Stability : Better than ± 0.03°C at full range
Block Radial Uniformity : ± 0.02°C at full range
Block Axial Uniformity (upto 40mm) : ± 0.20°C at -35°C
± 0.05°C at 0°C
± 0.05°C at 50°C
± 0.17°C at 100°C
Loading effect: Better than ± 0.08°C
Hysteresis: Better than ± 0.03°C
Heating time: 25 mins (25 to 120 °C)
75 mins (-35 to 120 °C)
52 mins (-35 to 25 °C)
Cooling time: 25 mins (25 to -35 °C)
15 mins (25 to -30 °C)
65 mins (120 to 25 °C)
Stabilization Time : 10 minutes
Test sensor immersion depth: 130 mm
Standard well holes in mm : Insert No. 1 →5.1, 6.2, 6.2 & 8.1, Insert No. 2 →6.2, 6.2 & 10.2
Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms
Cold junction Accuracy: ± 0.3°C
UUC Sensor supply input: 24V DC ± 10% / 50mA max.
Switch Test : Provided
Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption : 500 VA
Overall Dimension in mm : 390 x 185 x 356 (L x B x H)(Approx.)
Instrument Weight : 17.3 kg (with well insert)(Approx.)
Model: TCAL 1401/ - 30
Display: 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys
Temperature Range: -30 to 100°C (*@Ambient 25°C)
Radial Uniformity: Better than 0.15°C
Resolution: 0.1°C
Stability: ± 0.1°C
Temperature readout: °C
Heating time: 20 mins (Amb. To 100 °C)
Cooling time: 25 mins (25 to -30 °C)
Stabilization time: 10 minutes
Well Dimension (dia. X height): 22 x 120 mm
Standard well holes in mm: 5.2, 6.2 & 6.2
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power consumption: 500 VA
Overall Dimension in mm: 490 x 178 x 357 (L x B x H)(Approx.)
Instrument Weight: 12.5 kg (without well insert) (Approx.)
Model: TCAL 1404/500
Display: 2.8" True TFT with Touch screen
Temperature Range: Amb. + 5 to 500 °C
Radial uniformity: (Better than) ±0.05°C
Resolution: 0.01 °C
Stability: ±0.08 °C
Temperature readout: °C
Heating time: Amb to 500 --> 25 min
Cooling time: 500 to 50--> 1 hr 20 min
Stabilization time: 15 mins
Well Dimension(dia. x height): 20 x 100 mm
Well immersion depth: 90 mm
Standard well holes in mm: 6.2 x 2nos
Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
Power consumption: 350 w
Overall Dimension in mm: 170 x 95 x 183 mm
Instrument Weight: 3.75 Kg
Model TCAL: 1404/-15
Display: 2.8' True TFT with Touch screen
Temperature Range: -15 to 120 °C
Radial uniformity: (Better than) ±0.03°C
Resolution: 0.01 °C
Stability: ±0.03 °C
Temperature readout: °C
Heating time: Amb to 120-->25 min, -15 to Amb -->5 min
Cooling time: Amb to -15 -->20 min, 120 to 50 -->8 min
Stabilization time: 10 mins
Well Dimension(dia. x height): 20 x 90 mm
Well immersion depth: 90 mm (throw hole)
Standard well holes in mm: 6.2 x 2nos
Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz
Power consumption: 100 w
Overall Dimension in mm: 170 x 95 x 183 mm
Instrument Weight: 3.5 Kg
Model: TCAL 1404/-5
Display: 2.8' True TFT with Touch screen
Temperature Range: -5 to 100°C
Radial uniformity: (Better than) ±0.03°C
Resolution: 0.01 °C
Stability: ±0.03 °C
Temperature readout: °C
Heating time: Amb to 100-->15min, -5 to Amb -->3 min
Cooling time: Amb to -5 -->15min, 100 to 50-->4 min
Stabilization time: 10 mins
Well Dimension(dia. x height): 20 x 90 mm
Well immersion depth: 90 mm (throw hole)
Standard well holes in mm: 6.2 x 2nos
Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz
Power consumption: 100 w
Overall Dimension in mm: 170 x 95 x 183 mm
Instrument Weight: 3.5 Kg