Calibrators

Model : HCAL 1104U Display: 7” True colour TFT LCD Display with Touch screen Control Range : 5 to 60°C / 3 to 95 % RH* Dew point Temperature range (psychometric calculated) : -30°C to 45°C Psychometric calculated indication : Dew / Frost point ( Dp / Fp ) Wet Bulb Temperature ( Tw ) Vapour partial pressure ( E ) Vapour Saturation pressure ( Ew ) Mixing ratio by weight (dry) ( g / kg ) Enthalpy ( H ) ( KJ / kg ) Specific Humidity (moisture) ( g / kg ) Absolute Humidity (moisture) ( g / m³ ) Volume mixing ratio (dry) ( ppm ) Calculation method : WMO method Resolution : 0.01 °C / 0.01% RH Display stability : Better than ± 0.03 °C / ± 0.15% RH Chamber stability @25°C ** Temperature: ± 0.1°C, Humidity: ± 0.3 % RH Chamber Uniformity @25°C** Temperature: ± 0.2°C, Humidity: ± 0.5 % RH Test sensor insert port: Inter changeable Acrylic door is provided on front side of the chamber with pg21 gland (cable or sensor size range from 13 to 18mm) x 3nos External Humidifier Water tank capacity: 6 litres (approx.)(NOTE : 3 liter filling is enough for our application) Humidifier Liquid: Distilled water Humidifying Time:2 %RH / sec (50 to 90 % RH) Dehumidifying Time: 6 %RH / sec (50 to 10 % RH) Test chamber area: 230mm DIA x 170mm D (Approx) Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 1000 VA Construction: Inner chamber SS 310 / outer MS powder coating Overall Dimension: 436mm L x 676mm W x 368mm H (Approx.) Weight: 46 kg (without Accessories) + 6 kg (standard accessories) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Master Indicators

Measurement Range: Temperature (T): -20 to +100 °C Relative Saturation (RS): 0 to 100% RS Water Activity (aw): 0 to 1 aw Resolution : 0.01 °C / % RS & 1 aw Accuracy: aw (0...0.9 aw): ±0.02 aw at 23 °C aw (0...1.0 aw): Typically ±0.03 aw at 23 °C Temperature: ±0.3 °C Display: 2.8” True Colour TFT with Touch Screen Display Refresh Rate: 1 second (typical) Data Logging Interval: 1 sec to 24 Hours (user selectable) Data download: Via USB type-C to PC software (Sansel-Soft-01) Alarm: Audible & Visible, user-settable high & low alarms for all parameters Calibration: 2 point calibration for both temperature and humidity Touch sound: On / Off option available Integrated battery: 3.7 V / 10,000 mAh rechargeable polymer Li-ion battery Battery charging port: USB C-type Backlight Time Interval: Adjustable from 0(OFF) to 59 minutes and 59 seconds Brightness adjustment: 10% to 100% (user adjustable) Application Environment Range: -Temperature: -10°C to 60°C; -Humidity: 0% to 100% RH (non-condensed) Storage Environment Range: -Temperature: -10 to 45 °C ; -Humidity: 10 to 90% RH Housing Material: ABS with anti-slip grip silicon cover Protection Class: IP40 Dimension ( L x B x H): 35 x 80 x 165 mm Instrument Weight: 560 g (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : TCAL 1503 / -100 Display : 4.3” True colour TFT display with touch screen Temperature Range : -100°C to 40°C @20°C to 30°C Ambient Resolution : 0.01 °C Block Stability (30 mins) : Better than ± 0.03°C at full range Block Radial Uniformity : ± 0.05 °C at full range Temperature Read out : °C / °F (selectable) Heating time : 25°C to 40°C : 30 min -100 to 25°C : 80 min Cooling Time: 25°C to -100°C : 85 min 40 to 25°C : 12 min Stabilization time : 15 minutes Insert Dia. x Height: 30 x 120 mm Test sensor immersion depth: 115 mm Standard well holes in mm : Insert No. 1 : 5.1, 6.2, 6.2 & 8.1 Insert No. 2 : 6.2, 6.2 & 10.2 Measure inputs: RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, V, mV, Ohms Cold junction Accuracy: ± 0.3°C Communication: RS 485 MODBUS Switch Test: Provided Sensor supply output: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption : 500 VA Overall Dimension in mm : 356 x 210 x 534 (L x B x H)(Approx.) Instrument Weight :15.9 kg(with well insert)(Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : TCAL 1503 / -40 Display : 4.3” True colour TFT display with touch screen Temperature Range : -40 to 120°C @23°C Ambient Resolution : 0.01 °C Block Stability : Better than ± 0.03°C at full range Block Radial Uniformity : ± 0.02°C at full range Block Axial Uniformity (upto 40mm) : ± 0.18°C at -45°C ± 0.1°C at 0°C ± 0.05°C at 50°C ± 0.11°C at 100°C ± 0.17°C at 120°C Temperature Read out : °C / °F (selectable) Loading effect: Better than ± 0.08°C hysteresis: Better than ± 0.03°C Cooling time : 30 mins (25 to -45 °C) 15 mins (25 to -30 °C) 65 mins (120 to 25 °C) Heating time : 25 mins (25 to 120 °C) 75 mins (-45 to 120 °C) 52 mins (-45 to 25 °C) Stabilization time: 10 minutes Insert (Dia. x Height): 30 x 160 mm Test sensor immersion depth: 130 mm Standard well holes in mm: Insert No. 1 → 5.1, 6.2, 6.2 & 8.1, Insert No. 2 → 6.2, 6.2 & 10.2 Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms Cold junction Accuracy: ± 0.3°C UUC Sensor supply input: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (optional 110V AC) Power Consumption: 500 VA Switch Test : Provided Overall Dimension in mm: 390 x 185 x 356 (L x B x H) (Approx.) Weight: 17.3 kg (with well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : TCAL 1503 / -35 Display : 4.3” True colour TFT display with touch screen Temperature Range : -35 to 120 °C @ 23 °C Ambient Resolution : 0.01 °C Block Stability : Better than ± 0.03°C at full range Block Radial Uniformity : ± 0.02°C at full range Block Axial Uniformity (upto 40mm) : ± 0.20°C at -35°C ± 0.05°C at 0°C ± 0.05°C at 50°C ± 0.17°C at 100°C Loading effect: Better than ± 0.08°C Hysteresis: Better than ± 0.03°C Heating time: 25 mins (25 to 120 °C) 75 mins (-35 to 120 °C) 52 mins (-35 to 25 °C) Cooling time: 25 mins (25 to -35 °C) 15 mins (25 to -30 °C) 65 mins (120 to 25 °C) Stabilization Time : 10 minutes Test sensor immersion depth: 130 mm Standard well holes in mm : Insert No. 1 →5.1, 6.2, 6.2 & 8.1, Insert No. 2 →6.2, 6.2 & 10.2 Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N , Analog – mA, V, mV, ohms Cold junction Accuracy: ± 0.3°C UUC Sensor supply input: 24V DC ± 10% / 50mA max. Switch Test : Provided Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption : 500 VA Overall Dimension in mm : 390 x 185 x 356 (L x B x H)(Approx.) Instrument Weight : 17.3 kg (with well insert)(Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Process Control Instruments

Model: CC 603 - 1 Display: 4 + 4 Digit 0.5” & 0.39” 7 Seg RED LED Display Range (any one): 1 – 20µS, 5 – 200µS, 10 to 2000µS, 1 to 20mS, 5 to 200mS Resolution: 0.01µS to 0.1mS (depends on range) Accuracy: ±1% of range ±1 digit Cell Constant*: 0.01 / 0.1 / 1 (user selectable, depends on range) Temperature Sensor: RTD – PT 100 (3 wire) Temperature Co-efficient: 0 to 3% / °C (user adjustable) Temperature Compensation: Manual / Automatic (-20.0 to +150.0°C) Electrode Input: Conductivity cell on rear panel Set Point – 1 & 2: Two set points with 6 relay status selectable Relay Output: Relay-1 for Setpoint-1, Relay-2 for Setpoint-2 with 5A rating Relay Hysteresis: 0 to 500 counts (user adjustable) (only for High & Low control modes) Relay Cyclic Delay: 0 to 100 seconds (user adjustable) (only for High & Low control modes) Alarm Output (optional): Inbuilt audible buzzer with front key reset Optional Re-Tx Output: Galvanically isolated 4 – 20 mA Optional Comm. Output: Isolated RS-485 Comm. Protocol: MODBUS RTU Operating Environment: -10 to 50°C / 10 to 95% RH non-condensing Power Supply: 90 to 270V AC / DC, 50Hz Dimension: 96 × 96 × 85 mm Cutout Dimension: 92 × 92 mm Weight: 350 grams (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/300 Display: 2.8" True TFT with Touch screen Temperature Range: Amb. + 5 to 300 °C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.04 °C Temperature readout: °C Heating time: Amb to 300 -->23 min Cooling time: 300 to 50-->30 min Stabilization time: 15 mins Well Dimension(dia. x height): 20 x 100 mm Well immersion depth: 90 mm Standard well holes in mm: 6.2 x 2nos Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 250 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 2.75 Kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model TCAL: 1404/-15 Display: 2.8' True TFT with Touch screen Temperature Range: -15 to 120 °C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.03 °C Temperature readout: °C Heating time: Amb to 120-->25 min, -15 to Amb -->5 min Cooling time: Amb to -15 -->20 min, 120 to 50 -->8 min Stabilization time: 10 mins Well Dimension(dia. x height): 20 x 90 mm Well immersion depth: 90 mm (throw hole) Standard well holes in mm: 6.2 x 2nos Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz Power consumption: 100 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.5 Kg

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1404/-5 Display: 2.8' True TFT with Touch screen Temperature Range: -5 to 100°C Radial uniformity: (Better than) ±0.03°C Resolution: 0.01 °C Stability: ±0.03 °C Temperature readout: °C Heating time: Amb to 100-->15min, -5 to Amb -->3 min Cooling time: Amb to -5 -->15min, 100 to 50-->4 min Stabilization time: 10 mins Well Dimension(dia. x height): 20 x 90 mm Well immersion depth: 90 mm (throw hole) Standard well holes in mm: 6.2 x 2nos Power supply: 80 to 264VAC / 113 to 370VDC / 47 to 63Hz Power consumption: 100 w Overall Dimension in mm: 170 x 95 x 183 mm Instrument Weight: 3.5 Kg