Chennai
08048035791
+917299972093

'0 01 c chamber stability'

Items tagged with '0 01 c chamber stability'

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / 250 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range: Amb. +5 to 250°C Resolution: 0.01°C Stability: ± 0.03°C Accuracy: Better than ± 0.3°C Stabilization Time: 45 minutes Heating time: 60 mins (Amb. to 250°C) Cooling time: 90 mins (250 to 50°C ) Chamber Dimension: 80 x 140 mm (dia X depth) Testing area: 60 x 120 mm (dia X depth) Temperature medium: Silicon oil (200cs recommended) Measure inputs: RTD-PT 100, PT 1000 / TC-J, K, R, S, T, E, B , N / mA /mV / ohms PC Interface: RS 485 (optional) Power supply: 230V AC or 110V AC 50/60Hz Power Consumption: 1200 VA Switch test: Provided Dimension in mm: 340 x 175 x 425 (L x W x H) (Approx.) Weight (Approx.): 12 kg (without oil)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501/ - 40 Display: 3.5 inch True TFT LCD Display with Touch screen Temperature Range: -40 to 50°C Resolution: 0.01°C Heating & Cooling medium: ETHYLENE GLYCOL HOCH2CH2OH purity 99% (3litres) + Pure distilled water (1.5 litres ) for range from - 40 to 50 °C Stability: ± 0.05°C Uniformity: ± 0.2°C Stabilization Time: 15 minutes Heating time: 30 mins Cooling time: 60 mins (amb. (25°C to - 40°C ) @25°C Multi hole PP top cover: Provided for test Thermometer or sensor holding Power supply: 230V AC 50/60Hz Power Consumption: 1300 VA Calibration chamber size: 90 W x 120 H x 175 D mm Overall Dimension: 530 x 340 x 670 (L x W x H) (+155mm circulation motor) (Approx.) Weight: 52 kg (without liquid)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501 / 300 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range : Amb. to 300°C Resolution: 0.01°C Stability: ± 0.03°C Radial uniformity: Better than ± 0.2°C Measure inputs: RTD-PT 50, 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms Temperature Readout: C Stabilization Time: 15 minutes Heating time: 30 mins (25 to 600°C) Cooling time: 50 mins (600 to 100°C ) Well Dimension: 30 x 150 mm (dia x height) Test sensor immersion depth: 140 mm Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1 PC Interface (optional): RS 232 with automatic calibration software UUC Sensor supply output: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (optional 110V AC) Power Consumption: 1200 VA Switch test: Provided Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.) Weight: 8.5 kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: Tcal 1501 / -80 Display: 4.3 inch true TFT display with touch screen Working Range: -80 to -40 °C Resolution: 0.01 °C Stability: ± 0.03 °C Uniformity: ± 0.2 °C Bath Temperature Control: Digital Temperature Controller with FUZZY PID Multi Hole Well: Provided for Different type of Sensors, Sensor with Indicator & Thermometer Calibration Cooling medium: IPA Liquid Capacity: 5 Liters Testing Area: 100mm W x 100mm H x 190mm D Over all Dimension: 705mm L x 505mm W x 825mm H Power Supply: 230V AC ± 10% / 50Hz (Optional 110V44 AC) Weight: 80 kg (approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501 / 1200 Display: 4.3” True TFT LCD Display with Touch screen Temperature Range: 300 to 1200°C Resolution: 0.1°C Stability: Better than ± 0.5°C Radial uniformity: Better than ± 2°C Stabilization Time: 30 minutes Temperature readout: °C Heating time: 50 mins (Amb. to 1200°C) Cooling time: 120 mins (1200 to 100°C ) Well Dimension: 39 x 180 x 140 mm (dia x height x depth) Standard well holes in mm: 5.2, 6.2, 6.2, 10.1 & 12.1 Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 1900 VA Overall Dimension in mm: 340 x 175 x 425 (L x B x H) (Approx.) Weight: 18 kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : HCAL 1104U Display: 7” True colour TFT LCD Display with Touch screen Control Range : 5 to 60°C / 3 to 95 % RH* Dew point Temperature range (psychometric calculated) : -30°C to 45°C Psychometric calculated indication : Dew / Frost point ( Dp / Fp ) Wet Bulb Temperature ( Tw ) Vapour partial pressure ( E ) Vapour Saturation pressure ( Ew ) Mixing ratio by weight (dry) ( g / kg ) Enthalpy ( H ) ( KJ / kg ) Specific Humidity (moisture) ( g / kg ) Absolute Humidity (moisture) ( g / m³ ) Volume mixing ratio (dry) ( ppm ) Calculation method : WMO method Resolution : 0.01 °C / 0.01% RH Display stability : Better than ± 0.03 °C / ± 0.15% RH Chamber stability @25°C ** Temperature: ± 0.1°C, Humidity: ± 0.3 % RH Chamber Uniformity @25°C** Temperature: ± 0.2°C, Humidity: ± 0.5 % RH Test sensor insert port: Inter changeable Acrylic door is provided on front side of the chamber with pg21 gland (cable or sensor size range from 13 to 18mm) x 3nos External Humidifier Water tank capacity: 6 litres (approx.)(NOTE : 3 liter filling is enough for our application) Humidifier Liquid: Distilled water Humidifying Time:2 %RH / sec (50 to 90 % RH) Dehumidifying Time: 6 %RH / sec (50 to 10 % RH) Test chamber area: 230mm DIA x 170mm D (Approx) Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption: 1000 VA Construction: Inner chamber SS 310 / outer MS powder coating Overall Dimension: 436mm L x 676mm W x 368mm H (Approx.) Weight: 46 kg (without Accessories) + 6 kg (standard accessories) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1401 / 1200 Display: 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys Temperature Range: 500 to 1200°C Resolution: 1°C Stability: ± 2°C Radial Uniformity: Better than: ± 2°C Temperature readout: °C Heating time: 50 mins (Amb. To 1200 °C) Cooling time: 120 mins (1200 to 100 °C) Stabilization time: 30 minutes Well Dimension (dia. X height): 39 x 150 mm Standard well holes in mm: 5.2, 6.2, 6.2, 10.1 & 12.1 Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC) Power consumption: 1900 VA Overall Dimension in mm: 340 x 175 x 425 (L x B x H)(Approx.) Instrument Weight: 18 kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model : TCAL 1401 / 600 Display : 0.58” (15mm) (Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys Temperature Range : Amb.+5 to 600°C Resolution : 0.1°C Stability : ± 0.1°C Radial Uniformity : Better than ± 1°C Temperature Read out : °C Heating time : 30 mins (Amb. To 600 °C) Cooling time : 25 mins (600 to 100 °C) Stabilization time : 15 minutes Well Dimension (dia. X height) :30 x 110 mm Standard well holes in mm : 4.2, 6.2 , 6.2 & 8.5 Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC) Power Consumption : 1200 VA Overall Dimension in mm : 285 x 125 x 275 (L x B x H)(Approx.) Instrument Weight : 7.5 kg (without well insert) (Approx.)

68179d65be22ee500d53ff54 Card 2

product image
Calibrators

Model: TCAL 1501 / 600 Display: 4.3 inch True TFT LCD Display with Touch screen Temperature Range : Amb. +5 to 600°C Resolution: 0.01°C Stability: ± 0.05°C Radial uniformity: Better than ± 0.5°C Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms Temperature Readout: C Stabilization Time: 15 minutes Heating time: 30 mins (25 to 600°C) Cooling time: 50 mins (600 to 100°C ) Well Dimension: 30 x 150 mm (dia x height) Test sensor immersion depth: 140 mm Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1 PC Interface (optional): RS 232 with automatic calibration software UUC Sensor supply output: 24V DC ± 10% / 50mA max. Power supply: 230V AC ± 10% / 50Hz (optional 110V AC) Power Consumption: 1200 VA Switch test: Provided Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.) Weight: 8.5 kg (without well insert) (Approx.)

Still searching for
0 01 c chamber stability?